TC D · Civic campus zone (TC-D)
Sammamish, WA · SMC 21.07.020(F); 21.07.050(B) · Official code
By right: 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Townhouse | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Apartment | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Cottage housing | — | — | — | Home✓ ADU— | — |
| Community residential facility, I | — | — | — | — | HomeA ADU— |
| Community residential facility, II | — | — | — | — | HomeA ADU— |
| Dormitory | — | — | — | — | HomeA ADU— |
| Senior assisted housing | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set SMC 21.07.050(B) | 12 units SMC 21.07.060(D)(3)(f)
for Cottage housing (4+ units) |
| Minimum units | Not set SMC 21.07.050(B) | 4 units SMC 21.07.060(D)(3)(f)
for Cottage housing (4+ units) |
| Minimum lot width | No limit SMC 21.07.050(B) | |
| Minimum density | No limit SMC 21.07.050(B) | Not set SMC 21.07.050(B)(3)
for Community residential facility, I (group living); Community residential facility, II (group living); Dormitory (group living); Senior assisted housing (group living) |
| Maximum density | for Cottage housing (4+ units) Not set SMC 21.07.050(B)
for Community residential facility, I (group living); Community residential facility, II (group living); Dormitory (group living); Senior assisted housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft SMC 21.07.050(B) | |
| Side setback | 7 ft SMC 21.07.050(B)
for Cottage housing (4+ units) | |
| Rear setback | 20 ft SMC 21.07.050(B)
for Cottage housing (4+ units) | |
| Building separation | Not set SMC 21.07.050(B) | 10 ft SMC 21.07.060(D)(3)(e)
for Cottage housing (4+ units) |
| Maximum height | 60 ft SMC 21.07.050(B) | 25 ft SMC 21.07.060(D)(3)(e)
for Cottage housing (4+ units) |
| Minimum parking | 2 spaces per unit SMC 21.07.080(C)(1) | for Apartment (2, 3, 4+ units) 1.5 spaces per unit SMC 21.07.060(D)(3)(e)
for Cottage housing (4+ units) 0.5 × bedrooms in the whole project spaces SMC 21.07.080(C)(1)
for Community residential facility, I (group living); Community residential facility, II (group living); Dormitory (group living) 0.5 × (main dwelling units on the lot + sleeping units in the project) spaces SMC 21.07.080(C)(1)
for Senior assisted housing (group living) |
| Maximum unit size | Not set SMC 21.07.050(B) | 1,200 sq ft SMC 21.07.060(D)(3)(e)
for Cottage housing (4+ units) |
| Maximum building footprint | Not set SMC 21.07.050(B) | 1,000 sq ft SMC 21.07.060(D)(3)(g)(v)
for Cottage housing (4+ units) |
| Minimum open space | Not set SMC 21.07.050(B) | 40% SMC 21.07.060(D)(3)(e)
for Cottage housing (4+ units) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 21.09.010(B)(4) | A | up to 9 SMC 21.02.060(D)(3)(a) | — | Minimum lot size Not set SMC 21.07.050(B) |
| Subdivision SMC 21.09.010(B)(4) | H | 10 or more SMC 21.02.060(B)(32); 21.02.060(D)(3)(a) | — | Minimum lot size Not set SMC 21.07.050(B) |
| Unit lot subdivision SMC 21.02.060(H)(2); 21.09.010(B)(4) | A11 | up to 9 SMC 21.02.060(H)(2); 21.02.060(D)(3)(a) | — | Minimum lot size Not set SMC 21.02.060(H)(3) |
| Unit lot subdivision SMC 21.02.060(H)(2); 21.09.010(B)(4) | H11 | 10 or more SMC 21.02.060(H)(2); 21.02.060(B)(32); 21.02.060(D)(3)(a) | — | Minimum lot size Not set SMC 21.02.060(H)(3) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The project obtains bonus dwelling units under SMC 21.07.050.C
- The project obtains bonus dwelling units under SMC 21.07.050.C
- The property line abuts R-1 through R-8, TC-C or TC-E zones
- None of these is true:
- The property line abuts R-1 through R-8, TC-C or TC-E zones
- Bedrooms in one unit is at most 0
- Bedrooms in one unit is 1
- Bedrooms in one unit is 2
- Bedrooms in one unit is at least 3
- None of these is true:
- The site is part of a unified zone development plan
- The site is part of a unified zone development plan
- No dwelling units are stacked on other dwelling units or another use