CL · Commercial Low
SeaTac, WA · SMC 15.200.030(H); 15.400.200 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Multi-Family | — | — | — | HomeH ADU— | — |
| Retirement Apartments | — | — | — | HomeH ADU— | — |
| Co-Living | — | — | — | — | HomeH ADU— |
| Community Residential Facility I | — | — | — | — | Home✓ ADU— |
| Community Residential Facility II | — | — | — | — | HomeH ADU— |
| Continuing Care Retirement Community | — | — | — | — | HomeH ADU— |
| Convalescent Center/Nursing Home | — | — | — | — | Home✓ ADU— |
| Emergency Housing | — | — | — | — | Home✓ ADU— |
| Emergency Shelters | — | — | — | — | Home✓ ADU— |
| Permanent Supportive Housing | — | — | — | — | Home✓ ADU— |
| Transitional Housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | 7 units SMC 15.105.130 Multi-Family | Not set SMC 15.400.200
for Retirement Apartments (4+ units) |
| Maximum residents | Not set SMC 15.400.200 | 5 persons SMC 15.465.400(B)(1)(a)
for Community Residential Facility I (group living) No limit SMC 15.465.400(B)(2)
for Community Residential Facility II (group living) 80 persons SMC 15.465.350(B)(2)(a)(iii)
for Emergency Housing (group living); Emergency Shelters (group living) |
| Maximum beds | Not set SMC 15.400.200 | floor area of all units ÷ 35, rounded down beds SMC 15.465.350(B)(2)(a)(iii)
for Emergency Housing (group living); Emergency Shelters (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft SMC 15.400.200 | |
| Side setback | 5 ft SMC 15.400.200 | |
| Rear setback | 5 ft SMC 15.400.200 | |
| Maximum height | 35 ft SMC 15.400.200 | |
| Maximum lot coverage | 65% SMC 15.400.200 | |
| Minimum parking | Parking study from the applicant documenting the number of parking spaces needed by the land use submitted to and approved by the decision maker SMC 15.455.120 | for Multi-Family (4+ units) 0.75 spaces per unit SMC 15.455.120
for Retirement Apartments (4+ units) for Co-Living (group living) Parking study from the applicant documenting the number of parking spaces needed by the land use submitted to and approved by the decision maker. SMC 15.455.120
for Community Residential Facility I (group living) Parking plan based on population served and projected needs should be submitted and approved by the City Manager, or designee. SMC 15.455.120
for Community Residential Facility II (group living) 0.25 per assisted living unit/room 0.75 per retirement apartment dwelling unit 1 per 5 beds for convalescent/nursing care SMC 15.455.120
for Continuing Care Retirement Community (group living) 0.2 spaces per bed SMC 15.455.120
for Convalescent Center/Nursing Home (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, Short SMC 14.18.050(A) | A | up to 9 SMC 14.18.020(B) | — | Minimum lot size Not set SMC 15.400.200 |
| Subdivision, Long SMC 14.20.057(A) | H | 10 or more SMC 14.20.010 | — | Minimum lot size Not set SMC 15.400.200 |
| Binding Site Plan SMC 14.22.020(A) | A | 2 or more SMC 14.22.020(E) | — | Minimum lot size Not set SMC 14.22 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Bedrooms in one unit is less than 1
- All of these are true:
- Bedrooms in one unit is at least 1
- Bedrooms in one unit is less than 2
- Bedrooms in one unit is at least 2
- Lot is within a one-mile radius of SeaTac International Airport
- All of these are true:
- Lot is within a one-half-mile radius of a major transit stop
- Lot is within a one-mile radius of SeaTac International Airport
- None of these is true:
- Lot is within a one-mile radius of SeaTac International Airport
- Lot is within a one-half-mile radius of a major transit stop