RM · Residential Medium
SeaTac, WA · SMC 15.200.030(B); 15.400.100 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling Unit, Detached | Home✓ ADU✓ | — | — | — | — |
| Manufactured/Modular Home | Home✓ ADU✓ | — | — | — | — |
| Middle Housing | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Manufactured Home Park | — | — | — | HomeH ADU✓ | — |
| Community Residential Facility I | — | — | — | — | Home✓ ADU✓ |
| Emergency Housing | — | — | — | — | Home✓ ADU✓ |
| Emergency Shelters | — | — | — | — | Home✓ ADU✓ |
| Permanent Supportive Housing | — | — | — | — | Home✓ ADU✓ |
| Transitional Housing | — | — | — | — | Home✓ ADU✓ |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set SMC 15.400.100
for Manufactured Home Park (4+ units) | |
| Minimum lot size | 7,200 sq ft SMC 15.400.100 | Not set SMC 15.465.600(E)
for Manufactured Home Park (4+ units) |
| Maximum density | Not set SMC 15.400.100 | 7 units per acre SMC 15.465.600(E)(2)(b)
for Manufactured Home Park (4+ units) |
| Minimum development size | Not set SMC 15.400.100 | 130,680 sq ft SMC 15.465.600(E)(1)
for Manufactured Home Park (4+ units) |
| Maximum residents | 80 persons SMC 15.465.350(B)(2)(a)(ii) | 5 persons SMC 15.465.400(B)(1)(a)
for Community Residential Facility I (group living) Not set SMC 15.400.100
for Permanent Supportive Housing (group living); Transitional Housing (group living) |
| Maximum beds | Not set SMC 15.400.100 | floor area of all units ÷ 250, rounded down beds SMC 15.465.350(B)(2)(a)(ii)
for Emergency Housing (group living); Emergency Shelters (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft SMC 15.400.100 | |
| Side setback | 5 ft SMC 15.400.100 | |
| Rear setback | 10 ft SMC 15.400.100 | |
| Building separation | Not set SMC 15.400.100 | 16 ft SMC 15.465.600(E)(7)
for Manufactured Home Park (4+ units) |
| Maximum height | 40 ft SMC 15.400.100 | Conditionally permitted uses shall have their height limit established as a condition of CUP approval. SMC 15.400.100 Maximum Structure Height note (2)
for Manufactured Home Park (4+ units) |
| Maximum lot coverage | 55% SMC 15.400.100 | Not set SMC 15.465.600(E)(3)
for Manufactured Home Park (4+ units) |
| Minimum parking | Parking study from the applicant documenting the number of parking spaces needed by the land use submitted to and approved by the decision maker SMC 15.455.120 | 2 spaces per unit SMC 15.455.120
for Dwelling Unit, Detached (1 unit); Manufactured/Modular Home (1 unit); Manufactured Home Park (4+ units) for Middle Housing (2, 3, 4+ units) Parking study from the applicant documenting the number of parking spaces needed by the land use submitted to and approved by the decision maker. SMC 15.455.120
for Community Residential Facility I (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units SMC 15.465.100(C)(1)(a) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft SMC 15.465.100(D); 15.400.100 | |
| Side setback | 5 ft SMC 15.465.100(D); 15.400.100 | |
| Rear setback | 10 ft SMC 15.465.100(D); 15.400.100 | |
| Maximum height | 30 ft SMC 15.465.100(F)(1)-(2) | |
| Minimum parking |
|
|
| Maximum unit size | 1,000 sq ft SMC 15.465.100(E)(1)(b); 15.465.100(E)(2)(b); 15.465.100(E)(3)(a) | |
| Attached to the main house | Not required SMC 15.465.100(C)(1)(a)(i)-(iv) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, Short SMC 14.18.050(A) | A | up to 9 SMC 14.18.020(B) | — | Minimum lot size 7,200 sq ft SMC 15.400.100 |
| Subdivision, Long SMC 14.20.057(A) | H | 10 or more SMC 14.20.010 | — | Minimum lot size 7,200 sq ft SMC 15.400.100 |
| Binding Site Plan SMC 14.22.020(A) | A | 2 or more SMC 14.22.020(E) | — | Minimum lot size Not set SMC 14.22 |
| Unit Lot Subdivision SMC 14.18.090(A)Only for: Dwelling Unit, Detached, Middle Housing | A | up to 9 SMC 14.18.010 | Maximum units Not set SMC 14.18.090(C) |
Minimum lot size Not set SMC 14.18.090(B)-(C) Maximum units per lot 1 unit SMC 14.16.128 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- Lot is within one-quarter mile walking distance of a major transit stop
- Lot is within one-quarter mile walking distance of a major transit stop
- Lot is within a one-mile radius of SeaTac International Airport
- All of these are true:
- Lot is within a one-half-mile radius of a major transit stop
- Lot is within a one-mile radius of SeaTac International Airport
- All of these are true:
- Lot area is at most 6,000 sf
- Lot is within a one-mile radius of SeaTac International Airport
- Lot is within a one-half-mile radius of a major transit stop
- All of these are true:
- Lot area is more than 6,000 sf
- Lot is within a one-mile radius of SeaTac International Airport
- Lot is within a one-half-mile radius of a major transit stop
- None of these is true:
- Lot is within a one-mile radius of SeaTac International Airport
- Lot is within a one-half-mile radius of a major transit stop