Sign in

URH · Urban Residential High

SeaTac, WA · SMC 15.200.030(F); 15.400.100 · Official code

By right: 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Middle Housing—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Townhouse——
Home✓ ADU—
Home✓ ADU—
—
Multi-Family———
Home✓ ADU—
—
Retirement Apartments———
Home✓ ADU—
—
Co-Living————
Home✓ ADU—
Assisted Living Facility————
Home✓ ADU—
Community Residential Facility I————
Home✓ ADU—
Community Residential Facility II————
Home✓ ADU—
Continuing Care Retirement Community————
Home✓ ADU—
Convalescent Center/Nursing Home————
Home✓ ADU—
Emergency Housing————
Home✓ ADU—
Emergency Shelters————
Home✓ ADU—
Permanent Supportive Housing————
Home✓ ADU—
Transitional Housing————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum unitsNot set SMC 15.400.100
7 units SMC 15.105.130 Multi-Family
for Multi-Family (4+ units)
Maximum densityNot set SMC 15.400.100
1 unit per 900 sq ft SMC 15.400.100 Minimum Lot Area
for Middle Housing (2, 3, 4+ units)1; Townhouse (3, 4+ units); Multi-Family (4+ units)
1 unit per 900 ÷ 1.5 sq ft SMC 15.400.100 Minimum Lot Area; 15.400.100 Minimum Lot Area note (2)
for Retirement Apartments (4+ units)
Maximum residentsNot set SMC 15.400.100
5 persons SMC 15.465.400(B)(1)(a)
for Community Residential Facility I (group living)
No limit SMC 15.465.400(B)(2)
for Community Residential Facility II (group living)
80 persons SMC 15.465.350(B)(2)(a)(ii)
for Emergency Housing (group living); Emergency Shelters (group living)
Maximum bedsNot set SMC 15.400.100
floor area of all units ÷ 250, rounded down beds SMC 15.465.350(B)(2)(a)(ii)
for Emergency Housing (group living); Emergency Shelters (group living)
Maximum sleeping unitsNot set SMC 15.400.100
(4 × lot area) ÷ 900, rounded down sleeping units SMC 15.400.100 Minimum Lot Area note (3)
for Co-Living (group living)
(2 × lot area) ÷ 900, rounded down sleeping units SMC 15.400.100 Minimum Lot Area note (1)
for Assisted Living Facility (group living); Continuing Care Retirement Community (group living)

3. Building standards

StandardValueExceptions
Front setback10 ft SMC 15.400.100
Side setback5 ft SMC 15.400.100
Rear setback5 ft SMC 15.400.100
Maximum height55 ft SMC 15.400.100
Maximum lot coverage75% SMC 15.400.100
Minimum parking
  • 1.25 spaces per unit2 SMC 15.455.120
  • 0 spaces per unit3 SMC 15.455.120
  • 1 space per unit4 SMC 15.455.120
  • 1.25 spaces per unit5 SMC 15.455.120
  • 1 space per unit6 SMC 15.455.120
  • 1.5 spaces per unit7 SMC 15.455.120
  • 2 spaces per unit8 SMC 15.455.120
for Multi-Family (4+ units)
0.75 spaces per unit SMC 15.455.120
for Retirement Apartments (4+ units)
  • 0.5 spaces per sleeping unit2 SMC 15.455.120
  • 0 spaces per sleeping unit3 SMC 15.455.120
  • 0.25 spaces per sleeping unit9 SMC 15.455.120
for Co-Living (group living)
0.25 spaces per sleeping unit SMC 15.455.120
for Assisted Living Facility (group living)
Parking study from the applicant documenting the number of parking spaces needed by the land use submitted to and approved by the decision maker. SMC 15.455.120
for Community Residential Facility I (group living)
Parking plan based on population served and projected needs should be submitted and approved by the City Manager, or designee. SMC 15.455.120
for Community Residential Facility II (group living)
0.25 per assisted living unit/room 0.75 per retirement apartment dwelling unit 1 per 5 beds for convalescent/nursing care SMC 15.455.120
for Continuing Care Retirement Community (group living)
0.2 spaces per bed SMC 15.455.120
for Convalescent Center/Nursing Home (group living)
Parking study from the applicant documenting the number of parking spaces needed by the land use submitted to and approved by the decision maker SMC 15.455.120
for Emergency Housing (group living); Emergency Shelters (group living); Permanent Supportive Housing (group living); Transitional Housing (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision, Short SMC 14.18.050(A) A up to 9 SMC 14.18.020(B) —
Minimum lot size
Not set SMC 15.400.100
Subdivision, Long SMC 14.20.057(A) H 10 or more SMC 14.20.010 —
Minimum lot size
Not set SMC 15.400.100
Binding Site Plan SMC 14.22.020(A) A 2 or more SMC 14.22.020(E) —
Minimum lot size
Not set SMC 14.22
Unit Lot Subdivision SMC 14.18.090(A)Only for: Middle Housing, Townhouse A up to 9 SMC 14.18.010
Maximum units
Not set SMC 14.18.090(C)
Minimum lot size
Not set SMC 14.18.090(B)-(C)
Maximum units per lot
1 unit SMC 14.16.128

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Multi-family development is infeasible due to lot size or critical area constraints
  2. Lot is within a one-mile radius of SeaTac International Airport
  3. All of these are true:
    • Lot is within a one-half-mile radius of a major transit stop
    None of these is true:
    • Lot is within a one-mile radius of SeaTac International Airport
  4. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • Lot is within a one-mile radius of SeaTac International Airport
    • Lot is within a one-half-mile radius of a major transit stop
  5. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • Lot is within a one-mile radius of SeaTac International Airport
    • Lot is within a one-half-mile radius of a major transit stop
  6. Bedrooms in one unit is less than 1
  7. All of these are true:
    • Bedrooms in one unit is at least 1
    • Bedrooms in one unit is less than 2
  8. Bedrooms in one unit is at least 2
  9. None of these is true:
    • Lot is within a one-mile radius of SeaTac International Airport
    • Lot is within a one-half-mile radius of a major transit stop