Sign in

II U/160 · Industry and Innovation

Seattle, WA · SMC 23.50A · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Housing
HomeA1 ADUA1
HomeA1 ADUA1
HomeA1 ADUA1
HomeA1 ADUA1
—
Permanent supportive housing
HomeA1 ADU—
HomeA1 ADU—
HomeA1 ADU—
HomeA1 ADU—
—
Artist's studio/dwelling
HomeA2 ADU—
HomeA2 ADU—
HomeA2 ADU—
HomeA2 ADU—
—
Caretaker's quarters
Home✓3 ADU—
————
Congregate residence————
HomeA1 ADU—
Assisted living facility————
HomeA1 ADU—
Nursing home————
HomeA1 ADU—
Adult family home————
HomeA1 ADUA1

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

No standards.

3. Building standards

StandardValueExceptions
Maximum height
  • 30 ft4 SMC 23.50A.140(C)
  • 160 ft5 SMC 23.50A.140(B); 23.32
Maximum floor area ratio
  • 2.56 SMC 23.50A.100(A) Table A
  • 6.57 SMC 23.50A.120 Table A
Minimum parking
  • 0 spaces per unit8 SMC 23.54.015 Table B rows G, I
  • 0 spaces per unit9 SMC 23.54.015 Table B row K
  • 0.5 spaces per unit10 SMC 23.54.015 Table B row F
0 spaces per unit SMC 23.54.015 Table B row L
for Permanent supportive housing (1, 2, 3, 4+ units)1
  • 0 spaces per sleeping unit11 SMC 23.54.015 Table B rows G, I, J
  • 0 spaces per sleeping unit12 SMC 23.54.015 Table B row K
  • 0.25 spaces per sleeping unit13 SMC 23.54.015 Table B row D
for Congregate residence (group living)1
0 spaces per bed SMC 23.54.015 Table B row B
for Assisted living facility (group living)1; Nursing home (group living)1
Maximum unit sizeNot set SMC 23.50A.100
800 sq ft SMC 23.84A.032
for Caretaker's quarters (1 unit)3

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SMC 23.42.022(C)

Building

StandardValueExceptions
Maximum height
  • 30 ft4 SMC 23.42.022(E); 23.50A.140(C)
  • 160 ft5 SMC 23.42.022(E); 23.50A.140(B); 23.32
Minimum parking0 spaces per unit SMC 23.42.022(I); 23.54.015 Table B
Maximum unit size
  • 1,000 sq ft14 SMC 23.42.022(G)(1)(a)
  • 1,200 sq ft15 SMC 23.42.022(G)(1)(b)
Attached to the main houseNot required SMC 23.42.022(D)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 23.76.004 Table A; 23.24.050 A up to 9 SMC 23.84A.036 —
Minimum lot width
10 ft SMC 23.24.040(A)(9)(b)
Minimum frontage
  • 10 ft16 SMC 23.24.040(A)(9)(a)
  • Not set17 SMC 23.24.040(A)(9)(a)
Subdivision SMC 23.76.004 Table A; 23.76.024 H 10 or more SMC 23.84A.036 —
Minimum lot width
10 ft SMC 23.22.100(C)(3)(b)
Minimum frontage
  • 10 ft16 SMC 23.22.100(C)(3)(a)
  • Not set17 SMC 23.22.100(C)(3)(a)
Short subdivision, zero lot line SMC 23.76.004 Table A; 23.24.045Only for: Housing A up to 9 SMC 23.84A.036 —
Minimum lot size
Not set SMC 23.24.045(B)
Subdivision, zero lot line SMC 23.76.004 Table A; 23.22.062Only for: Housing H 10 or more SMC 23.84A.036 —
Minimum lot size
Not set SMC 23.22.062(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The residential use is within a structure designated as a Landmark under Chapter 25.12, or within a structure in a Landmark District under Chapter 25.16 or Chapter 25.28
  2. All of these are true:
    • The use is in a building existing on June 1, 2023 (established under permit, or with a permit granted and not expired, before June 1, 2023)
    • The occupant is a working artist whose artworks or performances are offered for sale or compensation or shown to a general public audience
  3. The dwelling unit is occupied by a caretaker or watchperson and is accessory to a nonresidential use on the lot
  4. The portion of the structure is within 20 feet of an abutting lot in a residential zone
  5. None of these is true:
    • The portion of the structure is within 20 feet of an abutting lot in a residential zone
  6. None of these is true:
    • The project gains extra floor area above the base FAR under Sections 23.50A.120 through 23.50A.128 (industrial use floor area, mass timber or TDR)
  7. The project gains extra floor area above the base FAR under Sections 23.50A.120 through 23.50A.128 (industrial use floor area, mass timber or TDR)
  8. Any of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
  9. All of these are true:
    • Floor area of one unit is less than 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
  10. All of these are true:
    • Floor area of one unit is at least 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
  11. Any of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
    • Lot is within a frequent transit service area (map adopted by Director's rule)
  12. All of these are true:
    • Floor area of all units is less than 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
    • Lot is within a frequent transit service area (map adopted by Director's rule)
  13. All of these are true:
    • Floor area of all units is at least 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
    • Lot is within a frequent transit service area (map adopted by Director's rule)
  14. Bedrooms in one ADU is at most 2
  15. Bedrooms in one ADU is at least 3
  16. The new lot is proposed with street frontage
  17. None of these is true:
    • The new lot is proposed with street frontage