MPC-YT · Master Planned Community - Yesler Terrace
Seattle, WA · SMC 23.75 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Housing | — | ||||
| Permanent supportive housing | — | ||||
| Artist's studio/dwelling | — | ||||
| Mobile home | — | — | — | — | |
| Caretaker's quarters | — | — | — | — | |
| Congregate residence | — | — | — | — | |
| Assisted living facility | — | — | — | — | |
| Nursing home | — | — | — | — | |
| Adult family home | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
No standards.
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | Not read SMC 23.75.140(A)(1) Exhibit A | |
| Street side setback | 10 ft SMC 23.75.140(A)(1)(a); 23.75.140(B) | |
| Rear setback | Not read SMC 23.75.140(A)(1) Exhibit A | |
| Building separation | ||
| Maximum height | Not read SMC 23.75.100(A) Exhibit A | |
| Minimum parking | 0 spaces per unit SMC 23.75.180(A)-(B) | |
| Maximum unit size | Not set SMC 23.75.085 | 800 sq ft SMC 23.84A.032
for Caretaker's quarters (1 unit)2 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units SMC 23.42.022(C) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | Not read SMC 23.42.022(E); 23.75.140(A)(1) Exhibit A | |
| Rear setback | Not read SMC 23.42.022(E); 23.75.140(A)(1) Exhibit A | |
| Maximum height | Not read SMC 23.42.022(E); 23.75.100(A) Exhibit A | |
| Minimum parking | 0 spaces per unit SMC 23.42.022(I); 23.75.180(B) | |
| Maximum unit size | ||
| Attached to the main house | Not required SMC 23.42.022(D) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 23.76.004 Table A; 23.24.050 | A | up to 9 SMC 23.84A.036 | — | Minimum lot width 10 ft SMC 23.24.040(A)(9)(b) |
| Subdivision SMC 23.76.004 Table A; 23.76.024 | H | 10 or more SMC 23.84A.036 | — | Minimum lot width 10 ft SMC 23.22.100(C)(3)(b) |
| Short subdivision, zero lot line SMC 23.76.004 Table A; 23.24.045Only for: Housing | A | up to 9 SMC 23.84A.036 | — | Minimum lot size Not set SMC 23.24.045(B) |
| Subdivision, zero lot line SMC 23.76.004 Table A; 23.22.062Only for: Housing | H | 10 or more SMC 23.84A.036 | — | Minimum lot size Not set SMC 23.22.062(B) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The lot is in Block 1 of the MPC-YT zone (Exhibit A for 23.75.020)
- All of these are true:
- The dwelling unit is occupied by a caretaker or watchperson and is accessory to a nonresidential use on the lot
- The lot is in Block 1 of the MPC-YT zone (Exhibit A for 23.75.020)
- The residential structure is partially separated from the street or park by a ground-floor-level courtyard at least 30 feet wide and 20 feet deep
- None of these is true:
- The residential structure is partially separated from the street or park by a ground-floor-level courtyard at least 30 feet wide and 20 feet deep
- All of these are true:
- Building height is more than 85
- The facade or smallest bounding rectangle of the proposed highrise structure overlaps the middle third of a facade or bounding-rectangle side of an existing highrise structure
- All of these are true:
- Building height is more than 85
- The facade or smallest bounding rectangle of the proposed highrise structure overlaps the middle third of a facade or bounding-rectangle side of an existing highrise structure
- Building height is at most 85
- Bedrooms in one ADU is at most 2
- Bedrooms in one ADU is at least 3
- The new lot is proposed with street frontage
- None of these is true:
- The new lot is proposed with street frontage