Sign in

R-15 · Residential 15 (R-15) Zone

Sedro-Woolley, WA · SWMC 17.16 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family residence
Home✓ ADUA
————
Dependent relative cottage—
Home✓1 ADU—
———
Multifamily residence—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Mobile home park—
HomeH ADU—
HomeH ADU—
HomeH ADU—
—
Group home————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit SWMC 17.16.030
Minimum densityNot set SWMC 17.16.040
4 units per acre SWMC 17.16.040
for Single-family residence (1 unit); Multifamily residence (2, 3, 4+ units)
Maximum density15 units per acre SWMC 17.16.040
Not set SWMC 17.16.040
for Dependent relative cottage (2 units)1; Group home (group living)
1 unit per 6,000 sq ft SWMC 17.48.030(A)
for Mobile home park (2, 3, 4+ units)

3. Building standards

StandardValueExceptions
Front setback10 ft SWMC 17.16.020(A)(1)
20 ft SWMC 17.48.030(B)(1)
for Mobile home park (2, 3, 4+ units)
Side setback
  • 5 ft2 SWMC 17.16.020(A)(2)
  • 8 ft3 SWMC 17.16.020(A)(2)
  • 8 + (4 × (building stories − 2)) ft4 SWMC 17.16.020(A)(2)
5 ft SWMC 17.04.030; 17.16.020(A)(2)
for Dependent relative cottage (2 units)1
Twenty feet from mobile home park boundaries and any public street right-of-way SWMC 17.48.030(B)(1)
for Mobile home park (2, 3, 4+ units)
Rear setback10 ft SWMC 17.16.020(A)(3)
5 ft SWMC 17.04.030; 17.16.020(A)(3)
for Dependent relative cottage (2 units)1
Twenty feet from mobile home park boundaries and any public street right-of-way SWMC 17.48.030(B)(1)
for Mobile home park (2, 3, 4+ units)
Maximum height35 ft SWMC 17.16.020(B)
20 ft SWMC 17.04.030; 17.16.020(B)
for Dependent relative cottage (2 units)1
Minimum parkingto be determined by the community development director or their designee SWMC 17.48.030(H); 17.36.030(N)
  • 1.5 spaces per unit5 SWMC 17.36.030(C)
  • 1.75 spaces per unit6 SWMC 17.36.030(C)
  • 2 spaces per unit7 SWMC 17.36.030(C)
  • 2.5 spaces per unit8 SWMC 17.36.030(C)
  • 3 spaces per unit9 SWMC 17.36.030(C)
for Single-family residence (1 unit); Dependent relative cottage (2 units)1
  • 2 spaces per unit10 SWMC 17.36.030(C)
  • 3 spaces per unit11 SWMC 17.36.030(C)
for Multifamily residence (2, 3 units)
  • 1.2 spaces per unit5 SWMC 17.36.030(C)
  • 1.5 spaces per unit6 SWMC 17.36.030(C)
  • 2 spaces per unit7 SWMC 17.36.030(C)
  • 2.5 spaces per unit8 SWMC 17.36.030(C)
  • 3 spaces per unit9 SWMC 17.36.030(C)
for Multifamily residence (4+ units)
one per resident between the ages of sixteen and fifty-nine, inclusive, excluding persons unable to drive due to disability, plus one-half per such younger, older or disabled person SWMC 17.36.030(B)
for Group home (group living)
Maximum units per buildingNot set SWMC 17.16
  • 8 units12 SWMC 17.16.010(A)(1)
  • 12 units13 SWMC 17.16.010(A)(1)
for Multifamily residence (2, 3, 4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SWMC 17.100.030(C)
Minimum lot sizeNo limit SWMC 17.100.030(B); 17.16.030

Building

StandardValueExceptions
Front setback10 ft SWMC 17.100.030(N); 17.16.020(A)(1)
Side setback
  • 5 ft14 SWMC 17.100.030(N); 17.16.020(A)(2)
  • 5 ft15 SWMC 17.100.030(N); 17.16.020(A)(2)
  • 8 ft16 SWMC 17.100.030(N); 17.16.020(A)(2)
  • 8 + (4 × (building stories − 2)) ft17 SWMC 17.100.030(N); 17.16.020(A)(2)
Rear setback
  • 5 ft14 SWMC 17.100.030(N); 17.16.020(A)(3)
  • 10 ft18 SWMC 17.100.030(N); 17.16.020(A)(3)
Maximum height
  • 24 ft19 SWMC 17.100.030(F)
  • 35 ft20 SWMC 17.100.030(F)
Minimum parking
  • 0 spaces per unit21 SWMC 17.100.030(K)
  • 1 space per unit22 SWMC 17.100.030(K)
  • 2 spaces per unit23 SWMC 17.100.030(K)
Maximum unit size1,000 sq ft SWMC 17.100.030(F)
Attached to the main houseNot required SWMC 17.100.030(D)-(E)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SWMC 16.12.050 A up to 4 SWMC 16.04.030(F); 16.12.010(A)
Minimum density
shall have an average net density, as defined in Section 17.04.030, for the entire development of not under four units per acre. SWMC 16.04.060(A)
Minimum lot size
No limit SWMC 17.16.030
Subdivision SWMC 16.08.024(A) H 5 or more SWMC 16.04.030(A)
Minimum density
shall have an average net density, as defined in Section 17.04.030, for the entire development of not under four units per acre. SWMC 16.04.060(A)
Minimum lot size
No limit SWMC 17.16.030
Planned residential development (PRD) SWMC 17.16.010(A)(9); 17.43.070; 16.08.024(A) H — 15 units per acre, on the net lot area SWMC 17.43.035(A)
Minimum parent area
130,680 sq ft SWMC 17.43.060(A)
Minimum density
shall have an average net density, as defined in Section 17.04.030, for the entire development of not under four units per acre. SWMC 16.04.060(A); 17.43.035(A)
Minimum lot size
Not set SWMC 17.43.060(B)
Zero side setbacks permitted SWMC 17.16.035(A)Only for: Townhouse ✓
Maximum lots
Not set SWMC 17.16.035
—
Maximum units per lot
1 unit SWMC 17.16.035(D)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The cottage is inhabited only by a relative who needs the support of family members nearby
    • The cottage is designed for ease of removal, dismantling, or conversion to an accessory use after the dependent relative use ends
  2. Building stories is at most 1
  3. Building stories is 2
  4. Building stories is more than 2
  5. Bedrooms in one unit is 0
  6. Bedrooms in one unit is 1
  7. Bedrooms in one unit is 2
  8. Bedrooms in one unit is 3
  9. Bedrooms in one unit is at least 4
  10. Bedrooms in one unit is at most 1
  11. Bedrooms in one unit is at least 2
  12. None of these is true:
    • The building is three stories and the units are evenly distributed between the three floors
  13. The building is three stories and the units are evenly distributed between the three floors
  14. The ADU is in a detached structure
  15. All of these are true:
    • Building stories is at most 1
    None of these is true:
    • The ADU is in a detached structure
  16. All of these are true:
    • Building stories is 2
    None of these is true:
    • The ADU is in a detached structure
  17. All of these are true:
    • Building stories is more than 2
    None of these is true:
    • The ADU is in a detached structure
  18. None of these is true:
    • The ADU is in a detached structure
  19. None of these is true:
    • The ADU is over a garage (carriage house)
  20. The ADU is over a garage (carriage house)
  21. Lot is within one-half mile walking distance of a major transit stop (RCW 36.70A.030(25))
  22. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop (RCW 36.70A.030(25))
  23. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop (RCW 36.70A.030(25))