Sign in

LDSF · Low density single-family residential (LDSF) zoning district

Selah, WA · SMC 10.10 · Official code

By right: 1 unit · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwelling
Home✓ ADU—
————
Manufactured homes
Home✓ ADU—
————
Mobile/manufactured home parks———
HomeH ADU—
—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum densityNot set SMC 10.10.030(a)
The density of a park or park expansion shall not exceed the underlying land use designation contained on the city of Selah Urban Growth Area Comprehensive Plan Future Land Use Map. SMC 10.26.030; 10.28.040(e)
for Mobile/manufactured home parks (4+ units)

3. Building standards

StandardValueExceptions
Front setback
  • 20 ft1 SMC 10.08.090
  • If the elevation of a lot rises or falls more than four feet in the first twenty feet measured from the front lot line, the required depth of the front yard shall be equal to the horizontal distance measured from the front lot line to where the average lot profile line intersects a horizontal line four feet above or below the front lot line, as determined by the building official.2 SMC 10.08.070
Side setback
  • the smallest of the largest of 0.1 × lot width, 5, 8 ft3 SMC 10.08.090
  • 8 ft4 SMC 10.08.090
Street side setback20 ft SMC 10.08.090
Rear setback20 ft SMC 10.08.090
Building separationNot set SMC 10.08.090; SMC 10.10
10 ft SMC 10.26.030(9)
for Mobile/manufactured home parks (4+ units)
Maximum height35 ft SMC 10.08.050
Maximum lot coverage35% SMC 10.08.040
Minimum parking3 spaces per unit SMC 10.34.020; 10.34.120 Table B
2 spaces per unit SMC 10.26.030(4)
for Mobile/manufactured home parks (4+ units)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 10.50.015D; 10.50.015A A up to 9 SMC 10.50.010 Not set SMC 10.10.030(a)
Minimum lot size
  • 10,000 sq ft5 SMC 10.10.030(a)
  • 217,800 sq ft6 SMC 10.10.030(a)
  • 217,800 sq ft7 SMC 10.10.030(a)
Minimum lot width
Not set SMC 10.10.030(a); 10.50.020
Minimum lot depth
Not set SMC 10.50.015A; SMC 10.10.030(a)
Minimum frontage
Not set SMC 10.50.015A; SMC 10.10.030(a)
Subdivision SMC 10.50.016J; 10.50.016K H 10 or more SMC 10.50.010 Not set SMC 10.10.030(a)
Minimum lot size
  • 10,000 sq ft5 SMC 10.10.030(a)
  • 217,800 sq ft6 SMC 10.10.030(a)
  • 217,800 sq ft7 SMC 10.10.030(a)
Minimum lot width
Not set SMC 10.10.030(a); 10.50.020
Minimum lot depth
85 ft SMC 10.50.023(a)(1)
Minimum frontage
24 ft SMC 10.50.023(b)(3)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The lot's elevation rises or falls more than four feet in the first twenty feet from the front lot line
  2. The lot's elevation rises or falls more than four feet in the first twenty feet from the front lot line
  3. Building stories is at most 1
  4. Building stories is more than 1
  5. All of these are true:
    • Slope class of the lot in the zone's minimum lot size table (<10%, 10-15%, 15-20%, 20-25%, >25%) is one of slope_under_10, slope_10_to_15, slope_15_to_20, slope_20_to_25
    • The lot is served by a municipal (public) water and sewage system
  6. All of these are true:
    • Slope class of the lot in the zone's minimum lot size table (<10%, 10-15%, 15-20%, 20-25%, >25%) is one of slope_under_10, slope_10_to_15, slope_15_to_20, slope_20_to_25
    None of these is true:
    • The lot is served by a municipal (public) water and sewage system
  7. Slope class of the lot in the zone's minimum lot size table (<10%, 10-15%, 15-20%, 20-25%, >25%) is slope_over_25