Sign in

LI-C · Low-intensity commercial

Shelton, WA · SMC 20.09 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwelling unit
Home✓ ADU✓
————
Duplex—
Home✓ ADU—
———
Triplex——
Home✓ ADU—
——
Multifamily residence———
Home✓ ADU—
—
Group home————
Home✓ ADU—
Institutional (such as hospitals, nursing homes, etc.)————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum units4 units SMC 20.04.590
Minimum lot size
  • 3,000 sq ft1 SMC 20.09.050(A)(1)
  • 4,500 sq ft2 SMC Table 20.09.050
  • 6,000 sq ft3 SMC Table 20.09.050

3. Building standards

StandardValueExceptions
Front setback
  • 10 ft4 SMC Table 20.09.050
  • the front yard required for new development shall be an average of the existing front yard setbacks, but shall not be less than that specified in Table 20.09.050.5 SMC 20.09.050(A)(2)
Maximum front setbackNo limit SMC Table 20.06.030(A)
Side setback5 ft SMC Table 20.09.050 note *
Street side setback7 ft SMC Table 20.09.050
Rear setback15 ft SMC Table 20.09.050
Maximum heightNo limit SMC Table 20.09.050
Maximum lot coverage
  • 55%6 SMC Table 20.09.050 note **
  • 35%7 SMC Table 20.09.050
Maximum impervious surface
  • 80%6 SMC Table 20.09.050 note **
  • 60%7 SMC Table 20.09.050
Minimum parking2 spaces per unit SMC 20.09.060; Table 20.40.100
2 + (1.5 × (main dwelling units on the lot − 1)) spaces SMC 20.09.060; Table 20.40.100
for Triplex (3 units); Multifamily residence (4+ units)
Uses which are not specifically listed shall be required to provide the amount of parking corresponding to the most similar listed use as determined by the planning department. SMC 20.40.100
for Group home (group living)
(beds in the project ÷ 3) + employees on the largest shift spaces SMC 20.09.060; Table 20.40.100
for Institutional (such as hospitals, nursing homes, etc.) (group living)
Maximum building floor area12,000 sq ft SMC Table 20.06.030(A); 20.09.080(D); 20.09.080(D)(1)
Maximum building footprint
  • 6,000 sq ft8 SMC Table 20.06.030(A) note 1; 20.44.330
  • 3,000 sq ft9 SMC Table 20.06.030(A); 20.09.080(D); 20.09.080(D)(1)
Maximum units per buildingNot set SMC 20.09.020(B)
16 units SMC 20.09.020(B)
for Multifamily residence (4+ units)

4. ADU standards

Lot

No standards.

Building

StandardValueExceptions
Front setback
  • 10 ft10 SMC 20.36.140(A)(1)
  • 10 ft11 SMC Table 20.09.050
  • the front yard required for new development shall be an average of the existing front yard setbacks, but shall not be less than that specified in Table 20.09.050.12 SMC 20.09.050(A)(2)
Side setback
  • 5 ft10 SMC 20.36.140(A)(3)
  • 5 ft13 SMC Table 20.09.050 note *
Rear setback
  • 2 ft14 SMC 20.36.140(A)(4)
  • 5 ft15 SMC 20.36.140(A)(3)
  • 15 ft13 SMC Table 20.09.050
Maximum height
  • 20 ft10 SMC 20.36.140
  • No limit13 SMC Table 20.09.050
Maximum stories
  • 1 story10 SMC 20.36.140
  • Not set13 SMC Table 20.09.050
Minimum parking1 space per unit SMC 20.64.040(C)
Maximum unit sizethe smallest of 1,000, 0.8 × floor area of the main house sq ft SMC 20.64.040(A)-(B)
Attached to the main houseNot required SMC 20.64.040(B); 20.64.040(D)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 19.28.040 A 2 to 4 SMC 19.28.010(A); SMC 19.28.010(A); 19.08.220 —
Minimum lot size
  • 4,500 sq ft16 SMC Table 20.09.050
  • 6,000 sq ft17 SMC Table 20.09.050
Subdivision SMC 19.16.020; 19.16.060(E) H
Minimum lots
5 lots SMC 19.16.010; 19.08.300
Maximum lots
Not set SMC 19.16
—
Minimum lot size
  • 4,500 sq ft16 SMC Table 20.09.050
  • 6,000 sq ft17 SMC Table 20.09.050
Binding site plan SMC 19.34.025; 19.34.050 H18
Maximum lots
Not set SMC 19.34
—
Minimum lot size
Not set SMC 19.34

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The lot was platted before the adoption of the LI-C code
  2. All of these are true:
    • The lot has an alley (the 'With Alleys' column of Table 20.09.050)
    None of these is true:
    • The lot was platted before the adoption of the LI-C code
  3. None of these is true:
    • The lot was platted before the adoption of the LI-C code
    • The lot has an alley (the 'With Alleys' column of Table 20.09.050)
  4. None of these is true:
    • Forty percent or more, on a front foot basis, of all property on the lot's side of the street between two intersecting streets has been built up (reached lot coverage)
  5. Forty percent or more, on a front foot basis, of all property on the lot's side of the street between two intersecting streets has been built up (reached lot coverage)
  6. The project provides through block access
  7. None of these is true:
    • The project provides through block access
  8. The project gets a conditional use permit for a ground floor of up to 6,000 sq ft
  9. None of these is true:
    • The project gets a conditional use permit for a ground floor of up to 6,000 sq ft
  10. The ADU is in a building detached from the main house
  11. None of these is true:
    • The ADU is in a building detached from the main house
    • Forty percent or more, on a front foot basis, of all property on the lot's side of the street between two intersecting streets has been built up (reached lot coverage)
  12. All of these are true:
    • Forty percent or more, on a front foot basis, of all property on the lot's side of the street between two intersecting streets has been built up (reached lot coverage)
    None of these is true:
    • The ADU is in a building detached from the main house
  13. None of these is true:
    • The ADU is in a building detached from the main house
  14. All of these are true:
    • The ADU is in a building detached from the main house
    • The rear lot line abuts a platted alley
  15. All of these are true:
    • The ADU is in a building detached from the main house
    None of these is true:
    • The rear lot line abuts a platted alley
  16. The lot has an alley (the 'With Alleys' column of Table 20.09.050)
  17. None of these is true:
    • The lot has an alley (the 'With Alleys' column of Table 20.09.050)
  18. Any of these is true:
    • The project is the establishment of a condominium development
    • The land is divided for lease (commercially or industrially zoned property)