R-1-10 · Single-Family District, R-1-10 subdistrict
Snoqualmie, WA · SMC 17.15 · Official code
By right: 1 unit · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-Family Dwellings: Site-Built, Modular and Designated Manufactured Home | Home✓ ADU✓ | — | — | — | — |
| Co-Housing | — | — | — | HomeH ADU✓ | — |
| Special Needs Housing | — | — | — | — | HomeH ADU✓ |
| Permanent Supportive Housing | — | — | — | — | Home✓ ADU✓ |
| Transitional Housing | — | — | — | — | Home✓ ADU✓ |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | ||
| Minimum lot width | ||
| Maximum density | 1 unit per 10,000 sq ft SMC 17.15.040(A) | |
| Maximum residents | Not set SMC 17.10.110 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft SMC 17.15.040(A) | |
| Side setback | 10 ft SMC 17.15.040(A) | |
| Street side setback | 20 ft SMC 17.15.040(A) | |
| Rear setback | 20 ft SMC 17.15.040(A) | |
| Maximum height | ||
| Maximum stories | ||
| Maximum impervious surface | ||
| Minimum parking | In the case of a use not specifically mentioned in Table 1, the requirements for off-street parking facilities shall be determined by the planning department. SMC 17.65.130 | 2 spaces per unit SMC 17.65.040(A); 17.65.150 Table 1
for Single-Family Dwellings: Site-Built, Modular and Designated Manufactured Home (1 unit) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units SMC 17.55.070(A) | |
| Minimum lot size | 0 sq ft SMC 17.15.040(A) Table 1 note 2 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft SMC 17.15.040(A) | |
| Side setback | 10 ft SMC 17.15.040(A) | |
| Rear setback | 20 ft SMC 17.15.040(A) | |
| Maximum height | 35 ft SMC 17.15.040(A) | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft SMC 17.55.070(D) | |
| Attached to the main house | Not required SMC 17.55.070(C) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 16.08.050Only for: Co-Housing, Permanent Supportive Housing, Single-Family Dwellings: Site-Built, Modular and Designated Manufactured Home, Special Needs Housing, Transitional Housing | A | up to 4 SMC 16.08.010 | — | |
| Subdivision SMC 16.10.040Only for: Co-Housing, Permanent Supportive Housing, Single-Family Dwellings: Site-Built, Modular and Designated Manufactured Home, Special Needs Housing, Transitional Housing | H | Maximum lots No limit SMC 16.10.010 |
— |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Existing flag lot
- None of these is true:
- Existing flag lot
- Lot has alley access
- None of these is true:
- Lot has alley access
- The special needs housing is a group home, for up to six residents in care, that functions as a single housekeeping unit and provides supportive services
- None of these is true:
- The special needs housing is a group home, for up to six residents in care, that functions as a single housekeeping unit and provides supportive services
- All of these are true:
- Existing flag lot
- Lot area is less than 10,000 sf
- All of these are true:
- Not all of these are true:
- Existing flag lot
- Lot area is less than 10,000 sf
- Lot width is more than 40 ft
- Not all of these are true:
- All of these are true:
- Not all of these are true:
- Existing flag lot
- Lot area is less than 10,000 sf
- Lot width is at most 40 ft
- Not all of these are true:
- Not all of these are true:
- Existing flag lot
- Lot area is less than 10,000 sf
- (main dwelling units on the lot × 43,560) ÷ lot area is less than 3.5
- All of these are true:
- (main dwelling units on the lot × 43,560) ÷ lot area is at least 3.5
- (main dwelling units on the lot × 43,560) ÷ lot area is less than 5
- All of these are true:
- (main dwelling units on the lot × 43,560) ÷ lot area is at least 5
- (main dwelling units on the lot × 43,560) ÷ lot area is less than 7
- All of these are true:
- (main dwelling units on the lot × 43,560) ÷ lot area is at least 7
- (main dwelling units on the lot × 43,560) ÷ lot area is less than 10
- All of these are true:
- (main dwelling units on the lot × 43,560) ÷ lot area is at least 10
- (main dwelling units on the lot × 43,560) ÷ lot area is less than 15
- (main dwelling units on the lot × 43,560) ÷ lot area is at least 15
- Any of these is true:
- Parcel is within one-half mile of a major transit stop
- Lot area is less than 6,000 sf
- All of these are true:
- Lot area is at least 6,000 sf
- Parcel is within one-half mile of a major transit stop