HI · Heavy Industrial
Spokane County, WA · SCC 14.614 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Secure community transition facility | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum frontage | 90 ft SCC 14.614.300(1) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft SCC 14.614.300(1) | |
| Side setback | ||
| Street side setback | 25 ft SCC 14.614.300(1) | |
| Rear setback | ||
| Maximum height | 65 ft SCC 14.614.300(1) | |
| Maximum lot coverage | 60% SCC 14.614.300(1) | |
| Minimum parking | Uses not specified in Tables 802-1 shall provide parking based on the most comparable use as determined by the Planning Director. SCC 14.802.040(2) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SCC 12.300.102; 12.300.116 | A5 | up to 9 SCC 12.300.102 | — | Minimum lot size Not set SCC 14.614.300(1) |
| Short subdivision SCC 12.300.102; 12.300.116 | A6 | up to 4 SCC 12.300.102 | — | Minimum lot size Not set SCC 14.614.300(1) |
| Subdivision SCC 12.400.102; 12.400.114; 12.400.118 | H5 | 10 or more SCC 12.400.102 | — | Minimum lot size Not set SCC 14.614.300(1) |
| Subdivision SCC 12.400.102; 12.400.114; 12.400.118 | H6 | 5 or more SCC 12.400.102 | — | Minimum lot size Not set SCC 14.614.300(1) |
| Large lot short subdivision SCC 12.600.102; 12.300.116 | A | up to 4 SCC 12.600.102 | — | Minimum lot size 217,800 sq ft SCC 12.600.102 Maximum lot size 871,200 sq ft SCC 12.600.102 |
| Large lot subdivision SCC 12.600.102; 12.600.118 | A | 5 or more SCC 12.600.102 | — | Minimum lot size 217,800 sq ft SCC 12.600.102 Maximum lot size 871,200 sq ft SCC 12.600.102 |
| Exempt division into lots of 1/32 section or 20 acres or larger SCC 12.100.110(1)(c); 12.100.112 | A | Maximum lots Not set SCC 12.100.110(1)(c) |
— | Minimum lot size 871,200 sq ft SCC 12.100.110(1)(c) |
| Exempt division of ten acres or greater SCC 12.100.110(3); 12.100.112 | A7 | Maximum lots Not set SCC 12.100.110(3) |
— | Minimum lot size 435,600 sq ft SCC 12.100.110(3) |
| Exempt division between five and twenty acres made before January 16, 1996 SCC 12.100.110(2); 12.100.110(2)(a)-(c) | — | — | — | — |
| Exempt division made before March 13, 1978 SCC 12.100.110(5); 12.100.110(5)(a)-(c) | — | — | — | — |
| Government or public purpose segregation SCC 12.100.110(6); 12.100.112 | A8 | Maximum lots Not set SCC 12.100.110(6) |
— | Minimum lot size Not set SCC 12.100.110(6) |
| Exempt division for transfer to a family member SCC 12.100.110(4); 12.100.112 | A9 | Maximum lots Not set SCC 12.100.110(4) |
— | Minimum lot size 217,800 sq ft SCC 12.100.110(4) |
| Binding site plan SCC 12.500.102; 12.500.116 | A | Maximum lots Not set SCC 12.500.102 |
— | Minimum lot size Not set SCC 14.614.300(1) |
| Planned unit development SCC 14.704.110(2)(a) | H | Maximum lots Not set SCC 14.704.300 |
— | Minimum frontage 90 ft SCC 14.704.320(2); 14.614.300(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- Any of these is true:
- The land is inside the Urban Growth Area boundary
- The site is in a zone within the Limited Development Area designation of the Comprehensive Plan
- The site is not across the street from, across the parking lot from, adjacent to, or within the line of sight (an unobstructed 600 feet) of a pre-existing public library, public playground, sports field, recreational center, community center, park or trail, school (pre-school to 12th grade), school bus stop, child day-care center, place of worship, another secure community transition facility, or other risk potential facility identified by DSHS
- Any of these is true:
- The side or rear lot line abuts a residential zone
- All of these are true:
- The side or rear lot line abuts an agricultural zone
- The side or rear lot line abuts a residential zone
- None of these is true:
- The side or rear lot line abuts a residential zone
- The side or rear lot line abuts an agricultural zone
- The land is inside the Urban Growth Area boundary
- None of these is true:
- The land is inside the Urban Growth Area boundary
- All of these are true:
- A record of survey for the property has been recorded with the Spokane County Auditor before the certificate of exemption is issued
- Any of these is true:
- None of these is true:
- The parcel fronts or accesses a county established and fully maintained road
- A valid Road Improvement District (RID) agreement pertaining to improvements to the county road is on file before the certificate of exemption is issued
- None of these is true:
- Any of these is true:
- The parcel is adjacent to, and has the zone minimum frontage on, an established and fully maintained public road
- The parcel is adjacent to, and has the zone minimum frontage on, a constructed private road that meets the Spokane County road standards and connects directly to an established and fully maintained county road
- All of these are true:
- The division contains no more than three (3) lots, each ten (10) acres or greater in size
- One or all of the lots are served by a recorded private driveway easement
- The driveway originates at an established and fully maintained county road
- One of the lots has the required frontage of the underlying zone classification on an established and fully maintained public road
- The segregation is a government or public purpose segregation, with an application submitted and the required purpose statement in the instrument of transfer
- The division transfers a separate tract to a spouse, son, daughter, mother, father, brother, sister, or grandchild, and ownership has not changed in the previous 5 years and will not transfer in the next 5 years