Sign in

IMU · Industrial Mixed Use (IMU)

Spokane Valley, WA · SVMC 19.60; 19.70 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, industrial accessory dwelling unit
HomeH1 ADU—
HomeH1 ADU—
HomeH1 ADU—
HomeH1 ADU—
—
Emergency housing————
HomeA2 ADU—
Emergency shelter————
HomeA2 ADU—
Transitional housing————
HomeA ADU—
Permanent supportive housing————
HomeA2 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units10 units SVMC 19.40.040(A)(2)
Maximum density22 units per acre SVMC 19.70.050(G); 19.70.020 Table 19.70-1
Not set SVMC 19.70.050(G); 19.70.020 Table 19.70-1
for Emergency housing (group living)2; Emergency shelter (group living)2; Transitional housing (group living); Permanent supportive housing (group living)2
Maximum residents20 persons SVMC 19.45.030(B)(1)

3. Building standards

StandardValueExceptions
Front setback15 ft SVMC 19.70.050(G); 19.70.020 Table 19.70-1
Side setback
  • 5 ft3 SVMC 19.70.050(G); 19.70.020 Table 19.70-1
  • 10 ft4 SVMC 19.70.050(G); 19.70.020 Table 19.70-1; 19.75.020(A)(1)(b); 19.75.030(A)
Street side setback15 ft SVMC 19.70.050(G); 19.70.020 Table 19.70-1
Rear setback10 ft SVMC 19.70.050(G); 19.70.020 Table 19.70-1
Maximum height
  • 50 ft5 SVMC 19.70.050(G); 19.70.020 Table 19.70-1
  • Starting at a height of 15 feet at the boundary of an R-1, R-2, R-3, or R-4 zone, the building height may be increased at a ratio of one foot of height for every one foot of horizontal distance from the nearest R-1, R-2, or R-3 zone boundary.6 SVMC 19.75.030(A)(2)(a)
Maximum lot coverage60% SVMC 19.70.050(G); 19.70.020 Table 19.70-1
Minimum parking1 space per unit SVMC 19.40.040(A)(3)
employees on the largest shift + 10 spaces SVMC 19.45.030(B)(5)(a); 19.45.030(B)(5)(c)
for Emergency housing (group living)2; Emergency shelter (group living)2; Transitional housing (group living); Permanent supportive housing (group living)2
Minimum open space
  • 10%7 SVMC 19.70.050(G); 19.70.020 Table 19.70-1; 19.70.050(F)(1)
  • 10 × 0.75%8 SVMC 19.70.050(G); 19.70.020 Table 19.70-1; 19.70.050(F)(1); 19.70.050(F)(2)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short Subdivision SVMC 20.30.030; 20.20.110 A up to 9 SVMC 20.20.010(L)(1) —
Minimum lot size
Not set SVMC 20.20.090(B)(3)(a); 19.70.050(G); 19.70.020 Table 19.70-1 note 4
Minimum lot width
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum lot depth
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum frontage
Not set SVMC 20.20.090(E)
Maximum units per lot
Not set SVMC 20.20.090
Subdivision SVMC 20.30.030; 20.20.100; 20.20.110 H 10 or more SVMC 20.20.010(L)(2) —
Minimum lot size
Not set SVMC 20.20.090(B)(3)(a); 19.70.050(G); 19.70.020 Table 19.70-1 note 4
Minimum lot width
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum lot depth
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum frontage
Not set SVMC 20.20.090(E)
Maximum units per lot
Not set SVMC 20.20.090
Binding Site Plan SVMC 20.30.030 A
Minimum lots
Not set SVMC 20.20.010(L)(3)
—
Minimum lot size
Not set SVMC 20.20.090(B)(3)(a); 19.70.050(G); 19.70.020 Table 19.70-1 note 4
Minimum lot width
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum lot depth
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum frontage
Not set SVMC 20.20.090(E)
Maximum units per lot
Not set SVMC 20.20.090

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The industrial ADU is developed in conjunction with an existing or new building on the site
  2. The site is at least one mile from the nearest property line of any other emergency shelter, emergency housing, permanent supportive housing or transitional parking use
  3. None of these is true:
    • The I or IMU property abuts a property not zoned I or IMU (the 10 ft ground level transitional setback applies on that side)
  4. The I or IMU property abuts a property not zoned I or IMU (the 10 ft ground level transitional setback applies on that side)
  5. None of these is true:
    • Part of the building lies where the upper level setback plane (15 ft at the R-1, R-2, R-3 or R-4 zone boundary, plus 1 ft of height per 1 ft of distance) is lower than the zone height limit
  6. Part of the building lies where the upper level setback plane (15 ft at the R-1, R-2, R-3 or R-4 zone boundary, plus 1 ft of height per 1 ft of distance) is lower than the zone height limit
  7. None of these is true:
    • The project provides at least two of the listed amenities (play or sports courts, playgrounds, trails, swimming pools, gazebos, clubhouses), reducing required open space by up to 25 percent
  8. The project provides at least two of the listed amenities (play or sports courts, playgrounds, trails, swimming pools, gazebos, clubhouses), reducing required open space by up to 25 percent