R2 · Residential 2

Spokane, WA · SMC 17C.111 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-Unit Residential Building
Home✓ ADU✓
————
Manufactured Home
Home✓1 ADU✓1
————
Middle housing—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Multi-Unit Residential Building——
Home✓ ADU✓
Home✓ ADU✓
—
Mobile Home Parks———
Home✓ ADU✓
—
Group Living————
Home✓2 H3 ADU✓2 ✓3
Alternative or Post Incarceration Facilities————
HomeH ADU✓
Co-living————
Home✓ ADU✓
Single Room Occupancy (SRO)————
Home✓ ADU✓

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNot set SMC 17C.111.200(C)(1)
435,600 sq ft SMC 17C.345.120(B)
for Mobile Home Parks (4+ units)
Minimum frontage
  • 15 ft4 SMC 17C.111.200(F); Table 17C.111.205-1
  • 36 ft5 SMC 17C.111.200(F); Table 17C.111.205-1
Minimum densityNot set SMC 17C.111.210(K)(1)
4 units per acre SMC 17C.345.120(E)
for Mobile Home Parks (4+ units)
Maximum density
  • No limit6 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 20 units per acre, rounded up7 SMC Table 17C.111.205-1; 17C.111.210(G)
10 units per acre SMC 17C.345.120(E)
for Mobile Home Parks (4+ units)
Not set SMC 17C.330.120(A)
for Group Living (group living)2; Group Living (group living)3; Alternative or Post Incarceration Facilities (group living); Co-living (group living); Single Room Occupancy (SRO) (group living)
Maximum residents2 × (lot area ÷ 1,000) persons SMC 17C.330.120(A)(3); Table 17C.330.120-1; 17C.111.110(A)(1)(a)
Not set SMC 17C.111.210
for Co-living (group living); Single Room Occupancy (SRO) (group living)
Maximum sleeping unitsNot set SMC 17C.330.120
  • No limit6 SMC 17C.111.210(J)(1)
  • 4 × (20 × (lot area ÷ 43,560)), rounded up sleeping units7 SMC Table 17C.111.205-1; 17C.111.210(F); 17C.111.210(H)
for Co-living (group living)
  • No limit6 SMC 17C.111.210(J)(1)
  • 20 × (lot area ÷ 43,560), rounded up sleeping units7 SMC Table 17C.111.205-1; 17C.111.210(H)
for Single Room Occupancy (SRO) (group living)

3. Building standards

StandardValueExceptions
Front setback10 ft SMC Table 17C.111.205-2; 17C.111.235(C)
20 ft SMC 17C.345.120(C)(1)(a)-(b)
for Mobile Home Parks (4+ units)
Side setback
  • 3 ft8 SMC Table 17C.111.205-2
  • 5 ft9 SMC Table 17C.111.205-2
20 ft SMC 17C.345.120(C)(1)(a)
for Mobile Home Parks (4+ units)
Street side setback5 ft SMC Table 17C.111.205-2
20 ft SMC 17C.345.120(C)(1)(b)
for Mobile Home Parks (4+ units)
Rear setback
  • The rear yard of a lot established as of May 27, 1929, may be reduced to provide a building depth of thirty (30) feet.10 SMC 17C.111.235(D)(1)
  • 15 ft11 SMC Table 17C.111.205-2; 17C.111.235(C)
20 ft SMC 17C.345.120(C)(1)(a)
for Mobile Home Parks (4+ units)
Building separationNot read SMC 17C.111.235(B)(1)
10 ft SMC 17C.345.120(C)(1)(d)
for Mobile Home Parks (4+ units)
Maximum height40 ft SMC Table 17C.111.205-2; 17C.111.230(B)
Maximum lot coverage
  • 90%12 SMC Table 17C.111.205-3; 17C.111.225(B)
  • 80%13 SMC Table 17C.111.205-1; 17C.111.220(B)
Maximum impervious surface
  • No limit14 SMC 17C.111.220(B)(2); Table 17C.111.205-1 note 8
  • 60%15 SMC Table 17C.111.205-1; 17C.111.220(B)(3)
  • 40%16 SMC Table 17C.111.205-1; 17C.111.220(B)(3)
Minimum parking0 spaces per unit SMC 17C.230.110(A); Table 17C.230.020-1; 17C.111.255(C)
1.5 spaces per unit SMC 17C.345.120(I)
for Mobile Home Parks (4+ units)
0 spaces per resident SMC 17C.230.110(A); Table 17C.230.020-1; 17C.330.120(D)
for Group Living (group living)2; Group Living (group living)3; Alternative or Post Incarceration Facilities (group living)
0 spaces per sleeping unit SMC 17C.230.110(A); Table 17C.230.020-1; 17C.330.120(D)
for Co-living (group living); Single Room Occupancy (SRO) (group living)
Maximum building footprint
  • 2,450 sq ft17 SMC Table 17C.111.205-2
  • 0.35 × lot area sq ft18 SMC Table 17C.111.205-2
Minimum open spaceNot set SMC Table 17C.111.205-2
15% SMC 17C.345.120(D)
for Mobile Home Parks (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SMC 17C.300.100(B)

Building

StandardValueExceptions
Front setback10 ft SMC 17C.111.235(B)(1); Table 17C.111.205-2
Side setback
  • 3 ft8 SMC Table 17C.111.205-2; 17C.300.130(B)(1)
  • 5 ft9 SMC Table 17C.111.205-2; 17C.300.130(B)(1)
Rear setback
  • 0 ft19 SMC Table 17C.111.205-2; 17C.300.130(B)(1)
  • 5 ft20 SMC Table 17C.111.205-2; 17C.300.130(B)(1)
Maximum height25 ft SMC Table 17C.111.205-2; 17C.300.130(B)(2); 17C.111.230(E)
Minimum parking0 spaces per unit SMC 17C.300.130(A)(3); 17C.230.110(A)
Maximum unit size1,000 sq ft SMC 17C.300.110(A)(1)(a); 17C.300.110(A)(2)(b)
Attached to the main houseNot required SMC 17C.300.100(A)
Owner lives on site
  • Required21 SMC 17C.300.110(B)
  • Not required22 SMC 17C.300.110(B)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short Subdivision SMC 17G.080.040; Table 17G.061.010-1 A up to 9 SMC 17A.020.190
  • No limit6 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 20 units per acre, rounded up7 SMC Table 17C.111.205-1; 17C.111.210(G)
Minimum density
10 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2)
Minimum lot size
1,200 sq ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot width
  • 15 ft4 SMC 17C.111.200(C)(1); Table 17C.111.205-1
  • 36 ft5 SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot depth
40 ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum frontage
  • 15 ft4 SMC 17C.111.200(F); Table 17C.111.205-1
  • 36 ft5 SMC 17C.111.200(F); Table 17C.111.205-1
Subdivision SMC 17G.080.050(D)-(E); Table 17G.061.010-1 H 10 or more SMC 17A.020.190
  • No limit6 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 20 units per acre, rounded up7 SMC Table 17C.111.205-1; 17C.111.210(G)
Minimum density
10 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2)
Minimum lot size
1,200 sq ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot width
  • 15 ft4 SMC 17C.111.200(C)(1); Table 17C.111.205-1
  • 36 ft5 SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot depth
40 ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum frontage
  • 15 ft4 SMC 17C.111.200(F); Table 17C.111.205-1
  • 36 ft5 SMC 17C.111.200(F); Table 17C.111.205-1
Binding Site Plan SMC 17G.080.060(C)(1); 17G.080.060(E); Table 17G.061.010-1 A —
  • No limit6 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 20 units per acre, rounded up7 SMC Table 17C.111.205-1; 17C.111.210(G)
Minimum density
10 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2)
Minimum lot size
1,200 sq ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot width
  • 15 ft4 SMC 17C.111.200(C)(1); Table 17C.111.205-1
  • 36 ft5 SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot depth
40 ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum frontage
  • 15 ft4 SMC 17C.111.200(F); Table 17C.111.205-1
  • 36 ft5 SMC 17C.111.200(F); Table 17C.111.205-1
Unit Lot Subdivisions SMC 17G.080.065(C); Table 17G.061.010-1 A23 up to 9 SMC 17G.080.065(C)
  • No limit6 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 20 units per acre, rounded up7 SMC Table 17C.111.205-1; 17C.111.210(G)
Maximum parent area
87,120 sq ft SMC Table 17C.111.205-1; 17G.080.065(B)(1)
Minimum density
10 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2)
Minimum lot size
No limit SMC Table 17C.111.205-1; 17G.080.065(D)(5)
Minimum lot depth
No limit SMC Table 17C.111.205-1
Unit Lot Subdivisions SMC 17G.080.065(C); Table 17G.061.010-1 H23 10 or more SMC 17G.080.065(C)
  • No limit6 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 20 units per acre, rounded up7 SMC Table 17C.111.205-1; 17C.111.210(G)
Maximum parent area
87,120 sq ft SMC Table 17C.111.205-1; 17G.080.065(B)(1)
Minimum density
10 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2)
Minimum lot size
No limit SMC Table 17C.111.205-1; 17G.080.065(D)(5)
Minimum lot depth
No limit SMC Table 17C.111.205-1

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The manufactured home is a new unit not previously titled to a retail purchaser
    None of these is true:
    • The lot is in a designated historic district
  2. Residents is at most 12
  3. Residents is more than 12
  4. None of these is true:
    • Lot is within an Airfield Overlay Zone
  5. Lot is within an Airfield Overlay Zone
  6. Lot area minus critical areas and buffers is at most 87,120 sf
  7. Lot area minus critical areas and buffers is more than 87,120 sf
  8. Lot width is at most 40 ft
  9. Lot width is more than 40 ft
  10. Lot was established as of May 27, 1929
  11. None of these is true:
    • Lot was established as of May 27, 1929
  12. Any of these is true:
    • The property is within one half mile of a major transit stop
    • The property is within one half mile of a Center & Corridor zone
    • All of these are true:
      • The property is owned by a Religious Organization
      • The development meets the affordability standards of SMC 17C.111.225(D) (e.g. 25% of units affordable to low-income households)
    • The development meets the affordability standards of SMC 17C.111.225(D) (e.g. 25% of units affordable to low-income households)
  13. None of these is true:
    • The property is within one half mile of a major transit stop
    • The property is within one half mile of a Center & Corridor zone
    • All of these are true:
      • The property is owned by a Religious Organization
      • The development meets the affordability standards of SMC 17C.111.225(D) (e.g. 25% of units affordable to low-income households)
    • The development meets the affordability standards of SMC 17C.111.225(D) (e.g. 25% of units affordable to low-income households)
  14. The application includes an engineer's stormwater drainage plan
  15. None of these is true:
    • The application includes an engineer's stormwater drainage plan
    • The site is in an Area of Drainage Concern
  16. All of these are true:
    • The site is in an Area of Drainage Concern
    None of these is true:
    • The application includes an engineer's stormwater drainage plan
  17. Lot area is at most 7,000 sf
  18. Lot area is more than 7,000 sf
  19. The lot has an alley at the rear
  20. None of these is true:
    • The lot has an alley at the rear
  21. The lot with the ADU also has a Short-Term Rental
  22. None of these is true:
    • The lot with the ADU also has a Short-Term Rental
  23. Main dwelling units on the lot is at least 2