Sign in

RA · Residential Agricultural

Spokane, WA · SMC 17C.111 · Official code

By right: 1 unit · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-Unit Residential Building
Home✓ ADU✓
————
Manufactured Home
Home✓1 ADU✓1
————
Mobile Home Parks———
HomeH ADU✓
—
Group Living————
Home✓2 H3 ADU✓2 ✓3
Alternative or Post Incarceration Facilities————
HomeH ADU✓

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNot set SMC 17C.111.200(C)(1)
435,600 sq ft SMC 17C.345.120(B)
for Mobile Home Parks (4+ units)
Minimum frontage40 ft SMC 17C.111.200(F); Table 17C.111.205-1
Minimum densityNot set SMC 17C.111.210(K)(1)
4 units per acre SMC 17C.345.120(E)
for Mobile Home Parks (4+ units)
Maximum densityNot set SMC 17C.330.120(A)
  • No limit4 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 10 units per acre, rounded up5 SMC Table 17C.111.205-1; 17C.111.210(G)
for Single-Unit Residential Building (1 unit); Manufactured Home (1 unit)1
10 units per acre SMC 17C.345.120(E)
for Mobile Home Parks (4+ units)
Maximum residents1.5 × (lot area ÷ 1,000) persons SMC 17C.330.120(A)(3); Table 17C.330.120-1; 17C.111.110(A)(1)(a)

3. Building standards

StandardValueExceptions
Front setback15 ft SMC Table 17C.111.205-2; 17C.111.235(C)
20 ft SMC 17C.345.120(C)(1)(a)-(b)
for Mobile Home Parks (4+ units)
Side setback
  • 3 ft6 SMC Table 17C.111.205-2
  • 5 ft7 SMC Table 17C.111.205-2
20 ft SMC 17C.345.120(C)(1)(a)
for Mobile Home Parks (4+ units)
Street side setback5 ft SMC Table 17C.111.205-2
20 ft SMC 17C.345.120(C)(1)(b)
for Mobile Home Parks (4+ units)
Rear setback
  • The rear yard of a lot established as of May 27, 1929, may be reduced to provide a building depth of thirty (30) feet.8 SMC 17C.111.235(D)(1)
  • 25 ft9 SMC Table 17C.111.205-2; 17C.111.235(C)
20 ft SMC 17C.345.120(C)(1)(a)
for Mobile Home Parks (4+ units)
Building separationNot read SMC 17C.111.235(B)(1)
10 ft SMC 17C.345.120(C)(1)(d)
for Mobile Home Parks (4+ units)
Maximum height35 ft SMC Table 17C.111.205-2; 17C.111.230(B)
Maximum lot coverage50% SMC Table 17C.111.205-1; 17C.111.220(B)
Maximum impervious surface
  • No limit10 SMC 17C.111.220(B)(2); Table 17C.111.205-1 note 8
  • 50%11 SMC Table 17C.111.205-1; 17C.111.220(B)(3)
  • 40%12 SMC Table 17C.111.205-1; 17C.111.220(B)(3)
Minimum parking0 spaces per resident SMC 17C.230.110(A); Table 17C.230.020-1; 17C.330.120(D)
0 spaces per unit SMC 17C.230.110(A); Table 17C.230.020-1; 17C.111.255(C)
for Single-Unit Residential Building (1 unit); Manufactured Home (1 unit)1
1.5 spaces per unit SMC 17C.345.120(I)
for Mobile Home Parks (4+ units)
Minimum open spaceNot set SMC Table 17C.111.205-2
15% SMC 17C.345.120(D)
for Mobile Home Parks (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SMC 17C.300.100(B)

Building

StandardValueExceptions
Front setback15 ft SMC 17C.111.235(B)(1); Table 17C.111.205-2
Side setback
  • 3 ft6 SMC Table 17C.111.205-2; 17C.300.130(B)(1)
  • 5 ft7 SMC Table 17C.111.205-2; 17C.300.130(B)(1)
Rear setback
  • 0 ft13 SMC Table 17C.111.205-2; 17C.300.130(B)(1)
  • 5 ft14 SMC Table 17C.111.205-2; 17C.300.130(B)(1)
Maximum height25 ft SMC Table 17C.111.205-2; 17C.300.130(B)(2); 17C.111.230(E)
Minimum parking0 spaces per unit SMC 17C.300.130(A)(3); 17C.230.110(A)
Maximum unit size1,000 sq ft SMC 17C.300.110(A)(1)(a); 17C.300.110(A)(2)(b)
Attached to the main houseNot required SMC 17C.300.100(A)
Owner lives on site
  • Required15 SMC 17C.300.110(B)
  • Not required16 SMC 17C.300.110(B)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short Subdivision SMC 17G.080.040; Table 17G.061.010-1 A up to 9 SMC 17A.020.190
  • No limit4 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 10 units per acre, rounded up5 SMC Table 17C.111.205-1; 17C.111.210(G)
Minimum density
4 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2)
Minimum lot size
7,200 sq ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot width
40 ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot depth
80 ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum frontage
40 ft SMC 17C.111.200(F); Table 17C.111.205-1
Subdivision SMC 17G.080.050(D)-(E); Table 17G.061.010-1 H 10 or more SMC 17A.020.190
  • No limit4 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 10 units per acre, rounded up5 SMC Table 17C.111.205-1; 17C.111.210(G)
Minimum density
4 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2)
Minimum lot size
7,200 sq ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot width
40 ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot depth
80 ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum frontage
40 ft SMC 17C.111.200(F); Table 17C.111.205-1
Binding Site Plan SMC 17G.080.060(C)(1); 17G.080.060(E); Table 17G.061.010-1 A —
  • No limit4 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 10 units per acre, rounded up5 SMC Table 17C.111.205-1; 17C.111.210(G)
Minimum density
4 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2)
Minimum lot size
7,200 sq ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot width
40 ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum lot depth
80 ft SMC 17C.111.200(C)(1); Table 17C.111.205-1
Minimum frontage
40 ft SMC 17C.111.200(F); Table 17C.111.205-1
Unit Lot Subdivisions SMC 17G.080.065(C); Table 17G.061.010-1 A17 up to 9 SMC 17G.080.065(C)
  • No limit4 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 10 units per acre, rounded up5 SMC Table 17C.111.205-1; 17C.111.210(G)
Maximum parent area
87,120 sq ft SMC Table 17C.111.205-1; 17G.080.065(B)(1)
Minimum density
4 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2)
Minimum lot size
No limit SMC Table 17C.111.205-1; 17G.080.065(D)(5)
Minimum lot depth
No limit SMC Table 17C.111.205-1
Unit Lot Subdivisions SMC 17G.080.065(C); Table 17G.061.010-1 H17 10 or more SMC 17G.080.065(C)
  • No limit4 SMC 17C.111.210(J)(1); Table 17C.111.205-1
  • 10 units per acre, rounded up5 SMC Table 17C.111.205-1; 17C.111.210(G)
Maximum parent area
87,120 sq ft SMC Table 17C.111.205-1; 17G.080.065(B)(1)
Minimum density
4 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2)
Minimum lot size
No limit SMC Table 17C.111.205-1; 17G.080.065(D)(5)
Minimum lot depth
No limit SMC Table 17C.111.205-1

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The manufactured home is a new unit not previously titled to a retail purchaser
    None of these is true:
    • The lot is in a designated historic district
  2. Residents is at most 6
  3. Residents is more than 6
  4. Lot area minus critical areas and buffers is at most 87,120 sf
  5. Lot area minus critical areas and buffers is more than 87,120 sf
  6. Lot width is at most 40 ft
  7. Lot width is more than 40 ft
  8. Lot was established as of May 27, 1929
  9. None of these is true:
    • Lot was established as of May 27, 1929
  10. The application includes an engineer's stormwater drainage plan
  11. None of these is true:
    • The application includes an engineer's stormwater drainage plan
    • The site is in an Area of Drainage Concern
  12. All of these are true:
    • The site is in an Area of Drainage Concern
    None of these is true:
    • The application includes an engineer's stormwater drainage plan
  13. The lot has an alley at the rear
  14. None of these is true:
    • The lot has an alley at the rear
  15. The lot with the ADU also has a Short-Term Rental
  16. None of these is true:
    • The lot with the ADU also has a Short-Term Rental
  17. Main dwelling units on the lot is at least 2