1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, Single-Family | Home✓ ADU✓ | — | — | — | — |
| Manufactured/Mobile Home | Home✓ ADU✓ | — | — | — | — |
| Dwelling, Duplex | — | Home✓ ADU— | — | — | — |
| Dwelling, Townhouse | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Dwelling, Multifamily | — | — | Home✓ ADU— | — | |
| Dwelling, Cottage | — | — | — | HomeH ADU— | — |
| Adult Family Home | — | — | — | — | Home✓ ADU✓ |
| Enhanced Service Facility Conversion Category 3 – Existing Adult Family Home Conversion of Up to a 6-Bed Facility | — | — | — | — | |
| Group Home | — | — | — | — | |
| Permanent Supportive Housing | — | — | — | — | Home✓ ADU— |
| Transitional Housing | — | — | — | — | HomeA ADU— |
| Assisted Living/Independent Living | — | — | — | — | HomeA ADU— |
| Co-living Housing | — | — | — | — | |
| Congregate Care Facility | — | — | — | — | HomeH ADU— |
| Enhanced Service Facility Conversion Category 1 – Existing Nursing Home Conversion of Up to a 16-Bed Facility | — | — | — | — | |
| Enhanced Service Facility Conversion Category 2 – Existing Assisted Living Conversion of Up to a 16-Bed Facility | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | Not set SMC 17.30.060 | 4 units SMC 18.402.130(3)(g)
for Dwelling, Cottage (4+ units) |
| Minimum lot size | 3,000 sq ft SMC 18.402.040(1) | 1,500 × main dwelling units on the lot sq ft SMC 18.402.040(1)
for Dwelling, Townhouse (2, 3, 4+ units) |
| Minimum lot width | 25 ft SMC 18.402.040(1) | |
| Minimum lot depth | 50 ft SMC 18.402.040(1) | |
| Minimum frontage | 20 ft SMC 17.20.020 | 35 ft SMC 18.402.130(3)(d)
for Dwelling, Cottage (4+ units) |
| Maximum density | 20 units per acre SMC 18.402.040(1) | Not set SMC 18.402.040(1)
for Adult Family Home (group living); Enhanced Service Facility Conversion Category 3 – Existing Adult Family Home Conversion of Up to a 6-Bed Facility (group living)4; Group Home (group living)5; Permanent Supportive Housing (group living); Transitional Housing (group living); Assisted Living/Independent Living (group living); Co-living Housing (group living)6; Congregate Care Facility (group living); Enhanced Service Facility Conversion Category 1 – Existing Nursing Home Conversion of Up to a 16-Bed Facility (group living)7; Enhanced Service Facility Conversion Category 2 – Existing Assisted Living Conversion of Up to a 16-Bed Facility (group living)8 |
| Maximum residents | Not set SMC 18.402.040(1) | for Enhanced Service Facility Conversion Category 3 – Existing Adult Family Home Conversion of Up to a 6-Bed Facility (group living)4; Group Home (group living)5; Enhanced Service Facility Conversion Category 1 – Existing Nursing Home Conversion of Up to a 16-Bed Facility (group living)7; Enhanced Service Facility Conversion Category 2 – Existing Assisted Living Conversion of Up to a 16-Bed Facility (group living)8 |
| Maximum beds | Not set SMC 18.402.040(1) | 6 beds SMC 17.30.060
for Enhanced Service Facility Conversion Category 3 – Existing Adult Family Home Conversion of Up to a 6-Bed Facility (group living)4 |
| Maximum sleeping units | Not set SMC 18.402.040(1) | 4 × ((20 × lot area) ÷ 43,560, rounded down) sleeping units SMC 18.402.040(1); 17.95.570(3)
for Co-living Housing (group living)6 Limited to 30 rooms/increment of minimum land area. SMC 17.30.060 note 6
for Congregate Care Facility (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft SMC 17.60.020(1) | |
| Side setback | for Dwelling, Duplex (2 units); Dwelling, Townhouse (2, 3, 4+ units) 5 + (5 × (the largest of building stories − 2, 0)) ft SMC 17.60.020(3); 17.25.100(6)
for Dwelling, Cottage (4+ units) | |
| Street side setback | 10 ft SMC 17.60.020(3)
for Dwelling, Duplex (2 units); Dwelling, Townhouse (2, 3, 4+ units); Dwelling, Cottage (4+ units) | |
| Rear setback | 5 ft SMC 17.60.020(1) | for Dwelling, Duplex (2 units); Dwelling, Townhouse (2, 3, 4+ units) |
| Building separation | More than one structure containing a permitted or permissible principal use may be erected on a single lot in conformance with the provisions of this code; provided, that required yard area, setbacks, lot area and other requirements of this code shall be met for each structure as though it were on an individual lot or as may be otherwise specified in this code. SMC 17.25.070 | |
| Maximum height | 40 ft SMC 17.60.020(1) | |
| Maximum stories | 3 stories SMC 17.60.020(1) | |
| Maximum lot coverage | 40% SMC 17.60.020(1) | 80% SMC 17.60.020(3)
for Dwelling, Duplex (2 units); Dwelling, Townhouse (2, 3, 4+ units) 60% SMC 17.60.020(3)
for Dwelling, Cottage (4+ units) |
| Minimum parking | Requirements for any use not specifically mentioned shall be the same as the use most similar to the one sought. In these instances, the planning director shall make this determination. SMC 17.105.140 | 2 spaces per unit SMC 17.105.140
for Dwelling, Single-Family (1 unit); Manufactured/Mobile Home (1 unit); Dwelling, Cottage (4+ units) for Dwelling, Duplex (2 units); Dwelling, Townhouse (2, 3, 4+ units) 1.5 spaces per bed SMC 17.105.140
for Group Home (group living)5 0.75 spaces per sleeping unit SMC 17.105.140
for Assisted Living/Independent Living (group living) for Co-living Housing (group living)6 (beds in the project ÷ 2) + (0.75 × employees on the largest shift) spaces SMC 17.105.140
for Congregate Care Facility (group living) |
| Maximum building floor area | Not set SMC 17.60.020(1) | 1,500 sq ft SMC 17.60.020(3); 18.402.130(3)(b)
for Dwelling, Cottage (4+ units) |
| Minimum open space | Not set SMC 17.60.020(1) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units SMC 17.95.480(1) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft SMC 17.60.020(3); 17.60.020(1) | |
| Side setback | 5 + (5 × (the largest of building stories − 2, 0)) ft SMC 17.60.020(3); 17.25.100(6) | |
| Rear setback | ||
| Maximum height | 24 ft SMC 17.95.480(4) | |
| Minimum parking | 1 space per unit SMC 17.95.480(6); 17.105.140 | |
| Maximum unit size | ||
| Attached to the main house | Not required SMC 17.95.480(2) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Lot split SMC 18.406.020(2); 18.230.020(2) | ✓29 | up to 2 SMC 18.402.110(3)(b); 18.406.010(1) | 20 units per acre SMC 18.402.040(1) Minimum parent area 2 × 3,000 sq ft SMC 18.402.110(3)(c); 18.402.040(1) |
Minimum lot size 3,000 sq ft SMC 18.402.110(3)(c); 18.402.040(1) Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 20 ft SMC 17.20.020 |
| Short subdivision SMC 18.400.020(1)(b); 18.230.020(5) | A | 2 to 9 SMC 18.102.200; SMC 18.400.020(1)(b) | 20 units per acre SMC 18.402.040(1) | Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 20 ft SMC 17.20.020 |
| Long subdivision SMC 18.400.020(1)(c); 18.230.020(5) | H | 10 or more SMC 18.400.020(1)(c) | 20 units per acre SMC 18.402.040(1) | Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 20 ft SMC 17.20.020 |
| Unit lot subdivision SMC 18.402.100; 18.400.020(1)(b); 18.230.020(5) | A | — | 20 units per acre SMC 18.402.040(1) Maximum units 3 units SMC 18.402.100(3)(a) |
Minimum lot size Within a unit lot subdivision, individual unit lots do not need to conform to minimum lot area requirements, minimum density, or other applicable dimensional and development standards for the zone, but the parent lot must comply with all applicable regulations. SMC 18.402.100(3)(b) |
| Cottage subdivision SMC 18.402.130; 18.400.020(1)(b); 18.230.020(5)Only for: Dwelling, Cottage | A | up to 9 SMC 18.400.020(1)(b) | 20 units per acre SMC 18.402.040(1) Minimum units 4 units SMC 18.402.130(3)(g) |
Minimum lot size 3,000 sq ft SMC 18.402.040(1) Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 35 ft SMC 18.402.130(3)(d) |
| Cottage subdivision SMC 18.402.130; 18.400.020(1)(c); 18.230.020(5)Only for: Dwelling, Cottage | H | 10 or more SMC 18.400.020(1)(c) | 20 units per acre SMC 18.402.040(1) Minimum units 4 units SMC 18.402.130(3)(g) |
Minimum lot size 3,000 sq ft SMC 18.402.040(1) Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 35 ft SMC 18.402.130(3)(d) |
| Zero lot line subdivision SMC 18.402.140(2); 18.400.020(1)(b); 18.230.020(5)Only for: Dwelling, Duplex, Dwelling, Townhouse | A | up to 9 SMC 18.400.020(1)(b) | 20 units per acre SMC 18.402.040(1) | Minimum lot size 1,500 sq ft SMC 18.402.040(1) Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 20 ft SMC 17.20.020 |
| Zero lot line subdivision SMC 18.402.140(2); 18.400.020(1)(c); 18.230.020(5)Only for: Dwelling, Duplex, Dwelling, Townhouse | H | 10 or more SMC 18.400.020(1)(c) | 20 units per acre SMC 18.402.040(1) | Minimum lot size 1,500 sq ft SMC 18.402.040(1) Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 20 ft SMC 17.20.020 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Main dwelling units on the lot is at most 9
- All of these are true:
- Main dwelling units on the lot is at least 10
- Main dwelling units on the lot is at most 60
- Main dwelling units on the lot is more than 60
- All of these are true:
- The building is a currently licensed adult family home (Chapter 70.128 RCW) being converted
- The site is within 1,200 feet, measured from property lines, of another special residential facility
- None of these is true:
- The site is within 1,200 feet, measured from property lines, of another special residential facility
- Lot area is at least 13,068 sf
- All of these are true:
- The building is a currently licensed nursing home (Chapter 18.51 RCW) being converted
- The site is within 1,200 feet, measured from property lines, of another special residential facility
- All of these are true:
- The building is a currently licensed assisted living facility (Chapter 18.20 RCW) being converted
- The site is within 1,200 feet, measured from property lines, of another special residential facility
- The Department of Social and Health Services approves services for up to eight adults under RCW 70.128.066
- None of these is true:
- The Department of Social and Health Services approves services for up to eight adults under RCW 70.128.066
- The home is on a local residential street
- None of these is true:
- The home is on a local residential street
- All of these are true:
- Existing lot (not a lot created by the proposed land division)
- Lot area is less than 10,100 sf
- Not all of these are true:
- Existing lot (not a lot created by the proposed land division)
- Lot area is less than 10,100 sf
- The side lot line is an internal lot line between attached units in a zero lot line subdivision or unit lot subdivision
- None of these is true:
- The side lot line is an internal lot line between attached units in a zero lot line subdivision or unit lot subdivision
- The rear lot line abuts an alley
- None of these is true:
- The rear lot line abuts an alley
- Bedrooms in one unit is at most 1
- Bedrooms in one unit is more than 1
- All of these are true:
- Bedrooms in one unit is at least 2
- Bedrooms in one unit is less than 3
- Bedrooms in one unit is at least 3
- Within one-half mile walking distance of a major transit stop
- None of these is true:
- Within one-half mile walking distance of a major transit stop
- Main dwelling units on the lot is at least 10
- The ADU is located entirely within an existing primary structure (interior ADU or garage conversion)
- All of these are true:
- Lot area is less than 12,400 sf
- The ADU is located entirely within an existing primary structure (interior ADU or garage conversion)
- All of these are true:
- Lot area is at least 12,400 sf
- The ADU is located entirely within an existing primary structure (interior ADU or garage conversion)
- None of these is true:
- The lot was created by a lot split
- The new lot is for an attached residential unit
- None of these is true:
- The new lot is for an attached residential unit