SR7.0 · SR (single-family residential) 7.0 zoning district
Stanwood, WA · SMC 17.30.060; 17.60.020 · Official code
By right: 1 unit, 2 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, Single-Family | Home✓ ADU✓ | — | — | — | — |
| Manufactured/Mobile Home | Home✓ ADU✓ | — | — | — | — |
| Dwelling, Duplex | — | Home✓ ADU— | — | — | — |
| Dwelling, Townhouse | — | — | |||
| Manufactured home park | — | — | — | Home✓ ADU— | — |
| Dwelling, Cottage | — | — | — | HomeH ADU— | — |
| Adult Family Home | — | — | — | — | Home✓ ADU✓ |
| Enhanced Service Facility Conversion Category 3 – Existing Adult Family Home Conversion of Up to a 6-Bed Facility | — | — | — | — | |
| Group Home | — | — | — | — | |
| Permanent Supportive Housing | — | — | — | — | Home✓ ADU— |
| Transitional Housing | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | Not set SMC 17.30.060 | 6 units SMC 17.95.395(1)
for Manufactured home park (4+ units) 4 units SMC 18.402.130(3)(g)
for Dwelling, Cottage (4+ units) |
| Minimum lot size | 5,000 sq ft SMC 18.402.040(1) | 1,500 × main dwelling units on the lot sq ft SMC 18.402.040(1)
for Dwelling, Townhouse (2, 3, 4+ units)1 130,680 sq ft SMC 17.95.415(2)(a); 17.30.060 note 13
for Manufactured home park (4+ units) |
| Minimum lot width | 25 ft SMC 18.402.040(1) | |
| Minimum lot depth | 50 ft SMC 18.402.040(1) | |
| Minimum frontage | 20 ft SMC 17.20.020 | 35 ft SMC 18.402.130(3)(d)
for Dwelling, Cottage (4+ units) |
| Maximum density | 8 units per acre SMC 18.402.040(1) | 10 units per acre SMC 18.402.130(3)(a)
for Dwelling, Cottage (4+ units) Not set SMC 18.402.040(1)
|
| Maximum residents | Not set SMC 18.402.040(1)
for Permanent Supportive Housing (group living); Transitional Housing (group living) | |
| Maximum beds | Not set SMC 18.402.040(1) | 6 beds SMC 17.30.060
for Enhanced Service Facility Conversion Category 3 – Existing Adult Family Home Conversion of Up to a 6-Bed Facility (group living)2 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft SMC 17.60.020(1) | |
| Side setback | 5 + (5 × (the largest of building stories − 2, 0)) ft SMC 17.60.020(1); 17.25.100(6) | |
| Street side setback | 15 ft SMC 17.60.020(1) | 10 ft SMC 17.60.020(3)
|
| Rear setback | 15 ft SMC 17.60.020(1) | |
| Building separation | More than one structure containing a permitted or permissible principal use may be erected on a single lot in conformance with the provisions of this code; provided, that required yard area, setbacks, lot area and other requirements of this code shall be met for each structure as though it were on an individual lot or as may be otherwise specified in this code. SMC 17.25.070 | 15 ft SMC 17.95.415(2)(c)
for Manufactured home park (4+ units) |
| Maximum height | 30 ft SMC 17.60.020(1) | |
| Maximum lot coverage | 40% SMC 17.60.020(1) | 80% SMC 17.60.020(3)
60% SMC 17.60.020(3)
for Dwelling, Cottage (4+ units) |
| Minimum parking | 2 spaces per unit SMC 17.105.140
for Dwelling, Single-Family (1 unit); Manufactured/Mobile Home (1 unit); Dwelling, Cottage (4+ units) 2 + (1 ÷ 5) spaces per unit SMC 17.105.140
for Manufactured home park (4+ units) Requirements for any use not specifically mentioned shall be the same as the use most similar to the one sought. In these instances, the planning director shall make this determination. SMC 17.105.140
for Adult Family Home (group living); Enhanced Service Facility Conversion Category 3 – Existing Adult Family Home Conversion of Up to a 6-Bed Facility (group living)2; Permanent Supportive Housing (group living); Transitional Housing (group living) 1.5 spaces per bed SMC 17.105.140
for Group Home (group living)3 | |
| Maximum building floor area | Not set SMC 17.60.020(1) | 1,500 sq ft SMC 17.60.020(3); 18.402.130(3)(b)
for Dwelling, Cottage (4+ units) |
| Minimum open space | Not set SMC 17.60.020(1) | |
| Maximum units per building | Not set SMC 17.60.020(1) | 4 units SMC 17.30.060 note 23
for Dwelling, Townhouse (2, 3, 4+ units)1 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units SMC 17.95.480(1) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft SMC 17.60.020(3); 17.60.020(1) | |
| Side setback | 5 + (5 × (the largest of building stories − 2, 0)) ft SMC 17.60.020(3); 17.25.100(6) | |
| Rear setback | ||
| Maximum height | 24 ft SMC 17.95.480(4) | |
| Minimum parking | 1 space per unit SMC 17.95.480(6); 17.105.140 | |
| Maximum unit size | ||
| Attached to the main house | Not required SMC 17.95.480(2) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Lot split SMC 18.406.020(2); 18.230.020(2) | ✓19 | up to 2 SMC 18.402.110(3)(b); 18.406.010(1) | 8 units per acre SMC 18.402.040(1) Minimum parent area 2 × 5,000 sq ft SMC 18.402.110(3)(c); 18.402.040(1) |
Minimum lot size 5,000 sq ft SMC 18.402.110(3)(c); 18.402.040(1) Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 20 ft SMC 17.20.020 |
| Short subdivision SMC 18.400.020(1)(b); 18.230.020(5) | A | 2 to 9 SMC 18.102.200; SMC 18.400.020(1)(b) | 8 units per acre SMC 18.402.040(1) | Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 20 ft SMC 17.20.020 |
| Long subdivision SMC 18.400.020(1)(c); 18.230.020(5) | H | 10 or more SMC 18.400.020(1)(c) | 8 units per acre SMC 18.402.040(1) | Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 20 ft SMC 17.20.020 |
| Unit lot subdivision SMC 18.402.100; 18.400.020(1)(b); 18.230.020(5) | A | — | 8 units per acre SMC 18.402.040(1) Maximum units 3 units SMC 18.402.100(3)(a) |
Minimum lot size Within a unit lot subdivision, individual unit lots do not need to conform to minimum lot area requirements, minimum density, or other applicable dimensional and development standards for the zone, but the parent lot must comply with all applicable regulations. SMC 18.402.100(3)(b) |
| Cottage subdivision SMC 18.402.130; 18.400.020(1)(b); 18.230.020(5)Only for: Dwelling, Cottage | A | up to 9 SMC 18.400.020(1)(b) | 10 units per acre SMC 18.402.130(3)(a) Minimum units 4 units SMC 18.402.130(3)(g) |
Minimum lot size 5,000 sq ft SMC 18.402.040(1) Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 35 ft SMC 18.402.130(3)(d) |
| Cottage subdivision SMC 18.402.130; 18.400.020(1)(c); 18.230.020(5)Only for: Dwelling, Cottage | H | 10 or more SMC 18.400.020(1)(c) | 10 units per acre SMC 18.402.130(3)(a) Minimum units 4 units SMC 18.402.130(3)(g) |
Minimum lot size 5,000 sq ft SMC 18.402.040(1) Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 35 ft SMC 18.402.130(3)(d) |
| Zero lot line subdivision SMC 18.402.140(2); 18.400.020(1)(b); 18.230.020(5)Only for: Dwelling, Duplex, Dwelling, Townhouse | A | up to 9 SMC 18.400.020(1)(b) | 8 units per acre SMC 18.402.040(1) | Minimum lot size 1,500 sq ft SMC 18.402.040(1) Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 20 ft SMC 17.20.020 |
| Zero lot line subdivision SMC 18.402.140(2); 18.400.020(1)(c); 18.230.020(5)Only for: Dwelling, Duplex, Dwelling, Townhouse | H | 10 or more SMC 18.400.020(1)(c) | 8 units per acre SMC 18.402.040(1) | Minimum lot size 1,500 sq ft SMC 18.402.040(1) Minimum lot width 25 ft SMC 18.402.040(1) Minimum lot depth 50 ft SMC 18.402.040(1) Minimum frontage 20 ft SMC 17.20.020 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Any of these is true:
- Lot is on a minor arterial or collector identified in the comprehensive plan
- Corner lot created within a new subdivision
- All of these are true:
- The building is a currently licensed adult family home (Chapter 70.128 RCW) being converted
- The site is within 1,200 feet, measured from property lines, of another special residential facility
- None of these is true:
- The site is within 1,200 feet, measured from property lines, of another special residential facility
- The home is on a local residential street
- None of these is true:
- The home is on a local residential street
- The Department of Social and Health Services approves services for up to eight adults under RCW 70.128.066
- None of these is true:
- The Department of Social and Health Services approves services for up to eight adults under RCW 70.128.066
- The side lot line is an internal lot line between attached units in a zero lot line subdivision or unit lot subdivision
- None of these is true:
- The side lot line is an internal lot line between attached units in a zero lot line subdivision or unit lot subdivision
- The rear lot line abuts an alley
- None of these is true:
- The rear lot line abuts an alley
- Bedrooms in one unit is at most 1
- Bedrooms in one unit is more than 1
- Main dwelling units on the lot is at most 9
- Main dwelling units on the lot is at least 10
- The ADU is located entirely within an existing primary structure (interior ADU or garage conversion)
- All of these are true:
- Lot area is less than 12,400 sf
- The ADU is located entirely within an existing primary structure (interior ADU or garage conversion)
- All of these are true:
- Lot area is at least 12,400 sf
- The ADU is located entirely within an existing primary structure (interior ADU or garage conversion)
- None of these is true:
- The lot was created by a lot split
- The new lot is for an attached residential unit
- None of these is true:
- The new lot is for an attached residential unit