Commercial, General · Commercial general (CG) district
Steilacoom, WA · SMC 18.12.040(a); 18.12.050 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Permanent supportive housing | — | ||||
| Transitional Housing | — | ||||
| Multifamily dwellings in principal buildings | — | — | — | ||
| Co-living sleeping units in principal buildings | — | — | — | — | |
| group care facilities | — | — | — | — | Home✓ ADU— |
| Emergency Housing | — | — | — | — | |
| Emergency Shelters | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 10 units SMC 18.16.080(B)(3) | Not set SMC 18.20.035
for Multifamily dwellings in principal buildings (4+ units)3 |
| Minimum lot size | 7,200 sq ft SMC 18.20.030(a) | |
| Minimum lot width | 60 ft SMC 18.20.030(a) | |
| Minimum frontage | ||
| Maximum density | 18 units per acre SMC 18.16.080(B)(3) | |
| Maximum residents | Not set SMC 18.16.065 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft SMC 18.20.020(a) | |
| Side setback | ||
| Street side setback | 0 ft SMC 18.20.020(a) | |
| Rear setback | 5 ft SMC 18.20.020(a) | |
| Maximum height | 26 ft SMC 18.20.040(a) | |
| Maximum lot coverage | No limit SMC 18.20.030(a) | |
| Maximum impervious surface | No limit SMC 18.20.030(a) | |
| Minimum parking | the smallest of bedrooms in one unit, 2 spaces per unit SMC 18.20.070(c) | 0.25 × sleeping units in the project, rounded down spaces SMC 18.20.070(c)
for Co-living sleeping units in principal buildings (group living)3 0.6 spaces per bed SMC 18.20.070(c)
for group care facilities (group living) |
| Maximum unit size | Not set SMC 18.20.100 | 300 sq ft SMC 18.16.100(B)(1)(a)
for Co-living sleeping units in principal buildings (group living)3 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units SMC 18.16.020(b)(1)(C) | |
| Minimum lot size | 7,200 sq ft SMC 18.16.020(b)(1)(C); 18.20.030(a) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft SMC 18.16.020(b)(1)(B); 18.20.020(a) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | 26 ft SMC 18.20.040(a) | |
| Minimum parking | 1 space per unit SMC 18.16.020(b)(2); 18.20.070(c) | |
| Maximum unit size | 1,000 sq ft SMC 18.16.020(b)(1)(E) | |
| Attached to the main house | Not required SMC 18.16.020(b)(1)(C)(i)-(iv) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 17.24.070(c) | A | Maximum lots the smallest of 4, lot area minus critical areas and buffers ÷ 7,200, rounded down lots SMC 17.04.040(t)(3); 17.08.030 |
— | Minimum lot size 7,200 sq ft SMC 17.08.020(a); 18.20.030(a) Minimum lot width 60 ft SMC 17.08.020(b)(1); 18.20.030(a) Minimum lot depth 60 ft SMC 17.08.020(b)(2); 18.20.030(a) |
| Subdivision SMC 17.12.050(e) | H | Minimum lots 5 lots SMC 17.04.040(t) Maximum lots lot area minus critical areas and buffers ÷ 7,200, rounded down lots SMC 17.08.030 |
— | Minimum lot size 7,200 sq ft SMC 17.08.020(a); 18.20.030(a) Minimum lot width 60 ft SMC 17.08.020(b)(1); 18.20.030(a) Minimum lot depth 60 ft SMC 17.08.020(b)(2); 18.20.030(a) |
| Planned area development SMC 17.32.050 | H15 | — | 12 units per acre SMC 17.32.020(d) | Minimum lot size Lots in planned area developments, SMC Chapter 17.32, may be less than the minimum lot size of the zone district. SMC 17.08.020(a)(2) Minimum lot width Lots in planned area developments, SMC Chapter 17.32, may be exempt from lot width, depth, area and side lot line requirements. SMC 17.08.020(b)(6) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- Site is within 880 feet of other permanent supportive housing, transitional housing, emergency housing or emergency shelter
- All of these are true:
- Any of these is true:
- The lot is connected to public sewers
- An existing on-site sewage disposal system has adequate capacity to serve all ADUs and principal units on the lot without expansion
- Site is within 880 feet of other permanent supportive housing, transitional housing, emergency housing or emergency shelter
- Any of these is true:
- The dwelling or sleeping units are in a principal building
- All of these are true:
- The dwelling or sleeping units are in a principal building
- Any of these is true:
- The lot is connected to public sewers
- An existing on-site sewage disposal system has adequate capacity to serve all ADUs and principal units on the lot without expansion
- None of these is true:
- An emergency housing facility already exists in the Town
- Site is within 880 feet of other permanent supportive housing, transitional housing, emergency housing or emergency shelter
- None of these is true:
- An emergency shelter already exists in the Town
- Site is within 880 feet of other permanent supportive housing, transitional housing, emergency housing or emergency shelter
- None of these is true:
- Lot fronts on a cul-de-sac
- Lot fronts on a cul-de-sac
- Property adjoins an "R" district
- None of these is true:
- Property adjoins an "R" district
- All of these are true:
- Property adjoins an "R" district
- The lot line where the detached ADU is sited abuts a public alley
- None of these is true:
- The lot line where the detached ADU is sited abuts a public alley
- Property adjoins an "R" district
- The lot line where the detached ADU is sited abuts a public alley
- None of these is true:
- The lot line where the detached ADU is sited abuts a public alley
- Any of these is true:
- Lot area is at least 108,900 sf
- The land is in an area regulated under SMC Chapter 16.16
- None of these is true:
- The land is in an area regulated under SMC Chapter 16.16
- The land is in an area regulated under SMC Chapter 16.16