Sign in

Residential - 9.6 · R-9.6 residential zoning district

Steilacoom, WA · SMC 18.12.020(B); 18.12.030 · Official code

By right: 1 unit, 2 units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
single family homes
Home✓ ADU✓1
————
Permanent supportive housing
Home✓2 ADU✓3
————
Transitional Housing
Home✓2 ADU✓3
————
duplexes—
Home✓ ADU✓1
———
cottage housing—
Home✓ ADU✓1
———
stacked flats—
Home✓ ADU✓1
———
courtyard apartments—
Home✓ ADU✓1
———
townhouses in PADs——
HomeH4 ADU✓5
HomeH4 ADU✓5
—
foster homes————
Home✓ ADU✓1
Adult Family Homes————
Home✓ ADU✓1
group care facilities————
Home✓6 H7 ADU—
assisted living facilities————
HomeH ADU—
class I boarding houses————
HomeA ADU—
class II boarding houses————
HomeH ADU—
halfway houses————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsThe number of townhouses within a PAD shall not exceed one-half of the permitted dwelling units allowed in the area subject to the PAD, multiplied by 1.43. SMC 17.32.020(b)
Minimum units3 units SMC 18.08.900
Minimum lot size9,600 sq ft SMC 18.20.030(a)
Lots in planned area developments, SMC Chapter 17.32, may be less than the minimum lot size of the zone district. SMC 17.08.020(a)(2)
for townhouses in PADs (3, 4+ units)4
Minimum lot width80 ft SMC 18.20.030(a)
Lots in planned area developments, SMC Chapter 17.32, may be exempt from lot width, depth, area and side lot line requirements. SMC 17.08.020(b)(6)
for townhouses in PADs (3, 4+ units)4
Minimum frontage
  • 80 ft8 SMC 17.08.020(b)(4)
  • 40 ft9 SMC 17.08.020(b)(4)
Maximum densityNot set SMC 18.20.035
The number of townhouses within a PAD shall not exceed one-half of the permitted dwelling units allowed in the area subject to the PAD, multiplied by 1.43. SMC 17.32.020(b)
for townhouses in PADs (3, 4+ units)4
Minimum development sizeNot set SMC 18.20.030
108,900 sq ft SMC 17.32.020
for townhouses in PADs (3, 4+ units)4
Maximum residentsNot set SMC 18.16.065
2 persons SMC 18.08.060
for class I boarding houses (group living)
5 persons SMC 18.08.065
for class II boarding houses (group living)
Maximum bedsNot set SMC 18.16.065
lot area ÷ 1,000, rounded down beds SMC 18.16.065(G)(2)
for assisted living facilities (group living)

3. Building standards

StandardValueExceptions
Front setback20 ft SMC 18.20.020(a)
Side setback5 ft SMC 18.20.020(a)
20 ft SMC 18.16.065(G)(3)
for assisted living facilities (group living)
Total side setbacks
  • 20 ft10 SMC 18.20.020(a)
  • 5 ft11 SMC 18.20.020(f)
Not set SMC 18.16.065(G)
for assisted living facilities (group living)
Street side setback20 ft SMC 18.20.020(f)
Rear setback20 ft SMC 18.20.020(a)
Maximum height26 ft SMC 18.20.040(a)
Maximum storiesNot set SMC 18.20.040
3 stories SMC 18.08.858
for stacked flats (2 units)
Maximum lot coverage30% SMC 18.20.030(a)
Maximum impervious surface50% SMC 18.20.030(a)
Minimum parking2 spaces per unit SMC 18.20.070(c)
0.6 spaces per bed SMC 18.20.070(c)
for foster homes (group living); group care facilities (group living)6; group care facilities (group living)7; assisted living facilities (group living)
2, rounded spaces SMC 18.16.065(F)(2)
for Adult Family Homes (group living)
2 + bedrooms in the whole project spaces SMC 18.16.060(C)(7); 18.20.070(c)
for class I boarding houses (group living); class II boarding houses (group living)
Any uses not listed in the "Parking Regulations" set forth in SMC 18.20.070(c) will be evaluated by the most similar listed use as determined by the Town of Steilacoom. SMC 18.20.070(b)(4)
for halfway houses (group living)
Maximum unit sizeNot set SMC 18.20.100
1,600 sq ft SMC 18.20.100(d)(1)
for cottage housing (2 units)
Minimum open spaceNot set SMC 18.20.030
20% SMC 18.20.100(d)(2)
for cottage housing (2 units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SMC 18.16.020(b)(1)(C)
Minimum lot size9,600 sq ft SMC 18.16.020(b)(1)(C); 18.20.030(a)

Building

StandardValueExceptions
Front setback20 ft SMC 18.16.020(b)(1)(B); 18.20.020(a)
Side setback
  • 5 ft12 SMC 18.20.020(a)
  • 0 ft13 SMC 18.16.020(b)(1)(B)(i)
Rear setback
  • 20 ft12 SMC 18.16.020(b)(1)(B); 18.20.020(a)
  • 0 ft13 SMC 18.16.020(b)(1)(B)(i)
Maximum height26 ft SMC 18.20.040(a)
Minimum parking1 space per unit SMC 18.16.020(b)(2); 18.20.070(c)
Maximum unit size1,000 sq ft SMC 18.16.020(b)(1)(E)
Attached to the main houseNot required SMC 18.16.020(b)(1)(C)(i)-(iv)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 17.24.070(c) A
Maximum lots
the smallest of 4, lot area minus critical areas and buffers ÷ 9,600, rounded down lots SMC 17.04.040(t)(3); 17.08.030
—
Minimum lot size
9,600 sq ft SMC 17.08.020(a); 18.20.030(a)
Minimum lot width
80 ft SMC 17.08.020(b)(1); 18.20.030(a)
Minimum lot depth
80 ft SMC 17.08.020(b)(2); 18.20.030(a)
Minimum frontage
  • 80 ft8 SMC 17.08.020(b)(4)
  • 40 ft9 SMC 17.08.020(b)(4)
Subdivision SMC 17.12.050(e) H
Minimum lots
5 lots SMC 17.04.040(t)
Maximum lots
lot area minus critical areas and buffers ÷ 9,600, rounded down lots SMC 17.08.030
—
Minimum lot size
9,600 sq ft SMC 17.08.020(a); 18.20.030(a)
Minimum lot width
80 ft SMC 17.08.020(b)(1); 18.20.030(a)
Minimum lot depth
80 ft SMC 17.08.020(b)(2); 18.20.030(a)
Minimum frontage
  • 80 ft8 SMC 17.08.020(b)(4)
  • 40 ft9 SMC 17.08.020(b)(4)
Unit lot subdivision SMC 17.24.100(a)(1); 17.24.070(c)Only for: single family homes, duplexes, cottage housing, stacked flats, courtyard apartments, townhouses in PADs A up to 4 SMC 17.24.100(a)(1); 17.04.040(t)(3)
Maximum units
2 units SMC 18.20.035(a)
Minimum lot size
Development as a whole on the parent lot, rather than individual unit lots, must comply with applicable design and development standards. SMC 17.24.100(a)(3)
Maximum units per lot
1 unit SMC 17.04.040(m)(ii)
Unit lot subdivision SMC 17.24.100(a)(1); 17.12.050(e)Only for: single family homes, duplexes, cottage housing, stacked flats, courtyard apartments, townhouses in PADs H 5 or more SMC 17.24.100(a)(1); 17.04.040(t)
Maximum units
2 units SMC 18.20.035(a)
Minimum lot size
Development as a whole on the parent lot, rather than individual unit lots, must comply with applicable design and development standards. SMC 17.24.100(a)(3)
Maximum units per lot
1 unit SMC 17.04.040(m)(ii)
Planned area development SMC 17.32.050 H14 —
Minimum parent area
  • 108,900 sq ft15 SMC 17.32.020
  • In areas regulated under SMC Chapter 16.16, PADs may be located on any size parcel that meets zoning requirements.16 SMC 17.32.020
Minimum lot size
Lots in planned area developments, SMC Chapter 17.32, may be less than the minimum lot size of the zone district. SMC 17.08.020(a)(2)
Minimum lot width
Lots in planned area developments, SMC Chapter 17.32, may be exempt from lot width, depth, area and side lot line requirements. SMC 17.08.020(b)(6)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Any of these is true:
    • The lot is connected to public sewers
    • An existing on-site sewage disposal system has adequate capacity to serve all ADUs and principal units on the lot without expansion
  2. None of these is true:
    • Site is within 880 feet of other permanent supportive housing, transitional housing, emergency housing or emergency shelter
  3. All of these are true:
    • Any of these is true:
      • The lot is connected to public sewers
      • An existing on-site sewage disposal system has adequate capacity to serve all ADUs and principal units on the lot without expansion
    None of these is true:
    • Site is within 880 feet of other permanent supportive housing, transitional housing, emergency housing or emergency shelter
  4. All of these are true:
    • The project is developed as a planned area development (PAD) under SMC Chapter 17.32
    • Any of these is true:
      • Lot area is at least 108,900 sf
      • The land is in an area regulated under SMC Chapter 16.16
  5. All of these are true:
    • The project is developed as a planned area development (PAD) under SMC Chapter 17.32
    • Any of these is true:
      • Lot area is at least 108,900 sf
      • The land is in an area regulated under SMC Chapter 16.16
    • Any of these is true:
      • The lot is connected to public sewers
      • An existing on-site sewage disposal system has adequate capacity to serve all ADUs and principal units on the lot without expansion
  6. None of these is true:
    • Another group care facility is already on the same residential block
  7. Another group care facility is already on the same residential block
  8. None of these is true:
    • Lot fronts on a cul-de-sac
  9. Lot fronts on a cul-de-sac
  10. None of these is true:
    • Residential corner lot (frontage on two or more streets where the streets meet)
  11. Residential corner lot (frontage on two or more streets where the streets meet)
  12. None of these is true:
    • The lot line where the detached ADU is sited abuts a public alley
  13. The lot line where the detached ADU is sited abuts a public alley
  14. Any of these is true:
    • Lot area is at least 108,900 sf
    • The land is in an area regulated under SMC Chapter 16.16
  15. None of these is true:
    • The land is in an area regulated under SMC Chapter 16.16
  16. The land is in an area regulated under SMC Chapter 16.16