Sign in

High Density Residential · High Density Residential (HDR) Zone

Sultan, WA · SMC 16.12.030 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family detached dwellings
Home✓ ADU✓
————
Manufactured homes
Home✓ ADU✓
————
Duplexes/two-family dwellings—
Home✓ ADU✓
———
Townhouses—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Cottage housing—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Apartments/multifamily dwellings———
Home✓ ADU✓
—
Group homes————
Home✓ ADU✓
Boarding houses————
Home✓ ADU✓
Residential care facilities————
Home✓ ADU✓
Co-living housing————
Home✓ ADU✓
Transitional housing————
Home✓1 ✓2 ✓3 ADU✓1 ✓2 ✓3
Permanent supportive housing————
Home✓1 ✓2 ✓3 ADU✓1 ✓2 ✓3

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum unitsNot set SMC 16.12.030(E); 16.36.090(A)
5 units SMC 16.04.040.29
for Apartments/multifamily dwellings (4+ units)
Minimum lot size2,000 × main dwelling units on the lot sq ft SMC 16.12.030(E); 16.36.090(A)
  • 3,000 sq ft4 SMC 16.12.030(E); 16.36.060(A)
  • No limit5 SMC 16.12.005(B)
for Single-family detached dwellings (1 unit); Manufactured homes (1 unit); Group homes (group living)
1,500 × main dwelling units on the lot sq ft SMC 16.12.030(E); 16.36.200(A)
for Cottage housing (2, 3, 4+ units)
8,000 + (1,000 × (the largest of main dwelling units on the lot − 4, 0)) sq ft SMC 16.12.030(E); 16.36.120(A)
for Apartments/multifamily dwellings (4+ units); Transitional housing (group living)3; Permanent supportive housing (group living)3
  • 10,000 sq ft4 SMC 16.12.030(E)
  • No limit5 SMC 16.12.005(B)
for Boarding houses (group living); Residential care facilities (group living)
8,000 + (250 × (the largest of sleeping units in the project − 24, 0)) sq ft SMC 16.12.030(E)
for Co-living housing (group living)
3,000 × main dwelling units on the lot sq ft SMC 16.12.030(E); 16.36.060(A)
for Transitional housing (group living)1; Permanent supportive housing (group living)1
Minimum lot width20 ft SMC 16.12.030(E); 16.36.090(A)
40 ft SMC 16.12.030(E); 16.36.060(A)
for Single-family detached dwellings (1 unit); Manufactured homes (1 unit); Group homes (group living); Transitional housing (group living)1; Permanent supportive housing (group living)1
Not set SMC 16.12.030(E); 16.36.200(A)
for Cottage housing (2, 3, 4+ units)
60 ft SMC 16.12.030(E); 16.36.120(A)
for Apartments/multifamily dwellings (4+ units); Residential care facilities (group living); Co-living housing (group living); Transitional housing (group living)3; Permanent supportive housing (group living)3
50 ft SMC 16.12.030(E)
for Boarding houses (group living)
Minimum lot depth80 ft SMC 16.12.030(E); 16.36.060(A)
Not set SMC 16.12.030(E); 16.36.200(A)
for Cottage housing (2, 3, 4+ units)
100 ft SMC 16.12.030(E)
for Boarding houses (group living); Residential care facilities (group living)
Minimum frontage20 ft SMC 16.04.010.3
Maximum density24 units per acre SMC 16.12.030(B)
No limit SMC 16.12.030(B)
for Cottage housing (2, 3, 4+ units); Co-living housing (group living)
Maximum residentsNot set SMC 16.12.030(E); 16.36.060(A)
20 persons SMC 16.04.020.18
for Boarding houses (group living)
Maximum sleeping unitsNot set SMC 16.12.030(E); 16.36.060(A)
10 sleeping units SMC 16.12.030(F)(4)
for Boarding houses (group living); Residential care facilities (group living)
No limit SMC 16.12.030(B)
for Co-living housing (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 15 ft6 SMC 16.12.030(E); 16.36.060(A)
  • 15 ft7 SMC 16.12.030(E); 16.36.060(A)
  • 15 ft8 SMC 16.12.030(E); 16.36.060(A)
  • 25 ft6 SMC 16.12.030(E)
  • 25 ft7 SMC 16.12.030(E)
  • 25 ft8 SMC 16.12.030(E)
for Boarding houses (group living); Residential care facilities (group living)
Side setback
  • 5 ft6 SMC 16.12.030(E); 16.36.060(A)
  • 10 ft7 SMC 16.12.030(E); 16.36.060(A); 16.12.030(F)(2)
  • 15 ft8 SMC 16.12.030(E); 16.36.060(A); 16.12.030(F)(2)
  • 10 ft6 SMC 16.12.030(E)
  • 10 ft7 SMC 16.12.030(E)
  • 15 ft8 SMC 16.12.030(E); 16.12.030(F)(2)
for Boarding houses (group living); Residential care facilities (group living)
Street side setback
  • 7.5 ft6 SMC 16.12.005(D)(2)(a); 16.12.030(E); 16.36.060(A)
  • 10 ft7 SMC 16.12.005(D)(2)(a); 16.12.030(E); 16.36.060(A); 16.12.030(F)(2)
  • 15 ft8 SMC 16.12.005(D)(2)(a); 16.12.030(E); 16.36.060(A); 16.12.030(F)(2)
  • 12.5 ft6 SMC 16.12.005(D)(2)(a); 16.12.030(E)
  • 12.5 ft7 SMC 16.12.005(D)(2)(a); 16.12.030(E)
  • 15 ft8 SMC 16.12.005(D)(2)(a); 16.12.030(E); 16.12.030(F)(2)
for Boarding houses (group living); Residential care facilities (group living)
Rear setback
  • 10 ft6 SMC 16.12.030(E); 16.36.060(A)
  • 10 ft7 SMC 16.12.030(E); 16.36.060(A)
  • 15 ft8 SMC 16.12.030(E); 16.36.060(A); 16.12.030(F)(2)
  • 15 ft6 SMC 16.12.030(E); 16.36.120(A)
  • 15 ft7 SMC 16.12.030(E); 16.36.120(A)
  • 15 ft8 SMC 16.12.030(E); 16.36.120(A)
for Apartments/multifamily dwellings (4+ units); Co-living housing (group living); Transitional housing (group living)3; Permanent supportive housing (group living)3
Building separationNot set SMC 16.12.030(E); 16.36.060(A)
10 ft SMC 16.36.200(A)
for Cottage housing (2, 3, 4+ units)
Maximum height30 ft SMC 16.12.030(E); 16.36.060(A)
24 ft SMC 16.12.030(E)
for Cottage housing (2, 3, 4+ units)
Maximum storiesNot set SMC 16.12.030(E); 16.36.060(A)
  • 1.5 stories9 SMC 16.36.200(B)
  • 2 stories10 SMC 16.36.200(B)
for Cottage housing (2, 3, 4+ units)
Maximum lot coverage60% SMC 16.12.030(E); 16.36.060(A)
Minimum parking
  • 1 space per unit11 SMC 16.54.140
  • 2 spaces per unit12 SMC 16.54.140
1 space per unit SMC 16.54.140
for Cottage housing (2, 3, 4+ units)
2 spaces per unit SMC 16.54.140
for Group homes (group living)
1 × bedrooms in the whole project spaces SMC 16.54.140
for Boarding houses (group living)
1 space per bed SMC 16.54.140
for Residential care facilities (group living)
0.25 spaces per sleeping unit SMC 16.54.140
for Co-living housing (group living)
1.25 × employees on the largest shift spaces SMC 16.54.140; 16.68.010(C)(3)(a)-(c)
for Transitional housing (group living)1; Transitional housing (group living)2; Transitional housing (group living)3; Permanent supportive housing (group living)1; Permanent supportive housing (group living)2; Permanent supportive housing (group living)3
Maximum building floor areaNot set SMC 16.12.030(E); 16.36.060(A)
  • Not set9 SMC 16.36.200(B)
  • 1,400 sq ft10 SMC 16.36.200(B)
for Cottage housing (2, 3, 4+ units)
Maximum building footprintNot set SMC 16.12.030(E); 16.36.060(A)
  • 800 sq ft9 SMC 16.36.200(B)
  • Not set10 SMC 16.36.200(B)
for Cottage housing (2, 3, 4+ units)
Minimum open space30% SMC 16.32.070(A); 16.32.100(A)(2)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SMC 16.12.005(F)(1)(a)-(b); 16.36.150
1 unit SMC 16.12.005(F)(1)(a)-(b); 16.36.150
for Duplexes/two-family dwellings (2 units)

Building

StandardValueExceptions
Front setbackFront yard setbacks for accessory dwelling units are 10 feet behind the primary structure unless a conversion of existing structure or a vertical addition to an existing garage that does not add to the existing footprint of the primary unit or its garage. SMC 16.12.005(F)(1)(d); 16.36.160(A)
Side setback
  • 5 ft6 SMC 16.36.160(A)
  • 10 ft7 SMC 16.36.160(A); 16.12.030(F)(2)
  • 15 ft8 SMC 16.36.160(A); 16.12.030(F)(2)
Rear setback
  • 5 ft6 SMC 16.36.160(A)
  • 10 ft7 SMC 16.36.160(A); 16.12.030(F)(2)
  • 15 ft8 SMC 16.36.160(A); 16.12.030(F)(2)
Maximum height24 ft SMC 16.36.160(A); 16.12.030(E)
Minimum parking1 space per unit SMC 16.54.140
Maximum unit size1,000 sq ft SMC 16.12.005(F)(1)(c); 16.36.160(A)
Attached to the main houseNot required SMC 16.36.150

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 19.12.050; 19.24.020(B) A up to 9 SMC 19.12.010; 19.04.020(A)(44) —
Minimum lot size
Not set SMC 19.14.050(A)
Minimum lot width
Not set SMC 19.14.050(A)
Minimum frontage
20 ft SMC 16.04.010.3
Subdivision SMC 19.06.060(A); 19.08.030; 19.26.020 H 10 or more SMC 19.06.020; 19.04.020(A)(49) —
Minimum lot size
Not set SMC 19.08.080(A)(2)
Minimum lot width
Not set SMC 19.08.080(A)(2)
Minimum frontage
20 ft SMC 16.04.010.3
Unit lot subdivision SMC 19.12.010; 19.14.110(A)(2); 19.24.020(B)Only for: Single-family detached dwellings, Manufactured homes, Duplexes/two-family dwellings, Townhouses, Cottage housing, Apartments/multifamily dwellings A 2 to 9 SMC 19.04.020(A)(51); SMC 19.14.110(A)(3) —
Minimum lot size
A unit lot may be as small as the footprint of the structure it contains, provided it meets applicable building, fire, and utility code requirements. SMC 19.14.110(B)(5)
Minimum lot width
Not set SMC 19.14.110(B)
Minimum frontage
Not set SMC 19.14.110(B)(3)
Lot size averaging SMC 19.44.020(A); 19.44.030(A); 19.04.020(A)(36); 19.12.050; 19.24.020(B)Only for: Single-family detached dwellings, Manufactured homes, Duplexes/two-family dwellings, Townhouses, Cottage housing A up to 9 SMC 19.12.010
Minimum average lot size
3,000 sq ft SMC 19.44.010(B); 19.44.040(A)(1)-(3); 16.12.030(E)
Minimum lot size
the largest of 0.8 × 3,000, 3,000 sq ft SMC 19.44.030(C)
Minimum lot width
40 ft SMC 19.44.030(D)
Minimum frontage
20 ft SMC 16.04.010.3
Lot size averaging SMC 19.44.020(A); 19.44.030(A); 19.04.020(A)(36); 19.06.060(A); 19.26.020Only for: Single-family detached dwellings, Manufactured homes, Duplexes/two-family dwellings, Townhouses, Cottage housing H 10 or more SMC 19.06.020
Minimum average lot size
3,000 sq ft SMC 19.44.010(B); 19.44.040(A)(1)-(3); 16.12.030(E)
Minimum lot size
the largest of 0.8 × 3,000, 3,000 sq ft SMC 19.44.030(C)
Minimum lot width
40 ft SMC 19.44.030(D)
Minimum frontage
20 ft SMC 16.04.010.3

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is detached
  2. The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is attached
  3. The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is stacked
  4. None of these is true:
    • The lot is an existing lot, not a lot created by a new division
  5. The lot is an existing lot, not a lot created by a new division
  6. Building height is at most 10
  7. All of these are true:
    • Building height is more than 10
    • Building height is at most 20
  8. Building height is more than 20
  9. The cottage is built to the Type A (1.5 stories, 800 sq ft footprint) or Type B (2 stories, 1,400 sq ft floor area) standards is type_a
  10. The cottage is built to the Type A (1.5 stories, 800 sq ft footprint) or Type B (2 stories, 1,400 sq ft floor area) standards is type_b
  11. Bedrooms in one unit is at most 1
  12. Bedrooms in one unit is more than 1