Sign in

Urban Center · Urban Center (UC) Zone

Sultan, WA · SMC 16.12.050 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Live/work dwelling units
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Apartments accessory to commercial uses
Home✓1 ADU✓1
————
Duplexes/two-family dwellings—
Home✓ ADU✓
———
Townhouses—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Apartments/multifamily dwellings———
Home✓ ADU✓
—
Boarding houses————
Home✓ ADU✓
Residential care facilities————
Home✓ ADU✓
Co-living housing————
Home✓ ADU✓
Emergency shelters————
Home✓ ADU✓
Emergency housing————
Home✓ ADU✓
Transitional housing————
Home✓2 ✓3 ✓4 ADU✓2 ✓3 ✓4
Permanent supportive housing————
Home✓2 ✓3 ✓4 ADU✓2 ✓3 ✓4

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum unitsNot set SMC 16.12.050(F); 16.36.090(A)
5 units SMC 16.04.040.29
for Apartments/multifamily dwellings (4+ units)
Minimum lot size1,800 × main dwelling units on the lot sq ft SMC 16.12.050(F); 16.36.090(A)
  • 2,500 sq ft5 SMC 16.12.050(F); 16.36.060(A)
  • No limit6 SMC 16.12.005(B)
for Live/work dwelling units (1 unit)
Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1
8,000 + (1,000 × (the largest of main dwelling units on the lot − 5, 0)) sq ft SMC 16.12.050(F); 16.36.120(A)
for Apartments/multifamily dwellings (4+ units); Transitional housing (group living)4; Permanent supportive housing (group living)4
  • 10,000 sq ft5 SMC 16.12.050(F)
  • No limit6 SMC 16.12.005(B)
for Boarding houses (group living); Residential care facilities (group living)
8,000 + (250 × (the largest of sleeping units in the project − 24, 0)) sq ft SMC 16.12.050(F)
for Co-living housing (group living)
  • 8,000 sq ft5 SMC 16.12.050(F)
  • No limit6 SMC 16.12.005(B)
for Emergency shelters (group living); Emergency housing (group living)
2,500 × main dwelling units on the lot sq ft SMC 16.12.050(F); 16.36.060(A)
for Transitional housing (group living)2; Permanent supportive housing (group living)2
Minimum frontage20 ft SMC 16.04.010.3
Maximum density30 units per acre SMC 16.12.050(B)
No limit SMC 16.12.050(B)
for Co-living housing (group living); Emergency shelters (group living); Emergency housing (group living)
Maximum residentsNot set SMC 16.12.050(F)
20 persons SMC 16.04.020.18
for Boarding houses (group living)
Maximum bedsNot set SMC 16.12.050(F)
30 beds SMC 16.12.050(G)(6)
for Emergency shelters (group living); Emergency housing (group living)
Maximum sleeping unitsNot set SMC 16.12.050(F); 16.36.060(A)
12 sleeping units SMC 16.12.050(G)(10)
for Boarding houses (group living); Residential care facilities (group living)
No limit SMC 16.12.050(B)
for Co-living housing (group living)
30 sleeping units SMC 16.12.050(G)(6)
for Emergency shelters (group living); Emergency housing (group living)

3. Building standards

StandardValueExceptions
Front setback10 ft SMC 16.12.050(F); 16.36.090(A)
15 ft SMC 16.12.050(F); 16.36.060(A)
for Live/work dwelling units (1 unit); Transitional housing (group living)2; Permanent supportive housing (group living)2
Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1
20 ft SMC 16.12.050(F)
for Boarding houses (group living); Residential care facilities (group living); Co-living housing (group living); Emergency shelters (group living); Emergency housing (group living)
Side setback5 ft SMC 16.12.050(F); 16.36.090(A)
3 ft SMC 16.12.050(F); 16.12.050(G)(4)
for Live/work dwelling units (1 unit); Transitional housing (group living)2; Permanent supportive housing (group living)2
Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1
10 ft SMC 16.12.050(F); 16.36.120(A)
for Apartments/multifamily dwellings (4+ units); Boarding houses (group living); Residential care facilities (group living); Co-living housing (group living); Emergency shelters (group living); Emergency housing (group living); Transitional housing (group living)4; Permanent supportive housing (group living)4
Street side setback5 ft SMC 16.12.005(D)(2)(a); 16.12.050(F); 16.36.090(A)
7.5 ft SMC 16.12.005(D)(2)(a); 16.12.050(F); 16.36.060(A)
for Live/work dwelling units (1 unit); Transitional housing (group living)2; Permanent supportive housing (group living)2
Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1
10 ft SMC 16.12.005(D)(2)(a); 16.12.050(F); 16.36.120(A)
for Apartments/multifamily dwellings (4+ units); Boarding houses (group living); Residential care facilities (group living); Co-living housing (group living); Emergency shelters (group living); Emergency housing (group living); Transitional housing (group living)4; Permanent supportive housing (group living)4
Rear setback10 ft SMC 16.12.050(F); 16.36.060(A)
Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1
20 ft SMC 16.12.050(F)
for Residential care facilities (group living)
Maximum height35 ft SMC 16.12.050(F); 16.36.060(A)
Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1
Maximum stories3 stories SMC 16.12.050(F); 16.36.060(A)
Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1
Maximum lot coverage80% SMC 16.12.050(F); 16.36.060(A)
Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1
Minimum parking
  • 1 space per unit7 SMC 16.54.140
  • 2 spaces per unit8 SMC 16.54.140
1.25 spaces per unit SMC 16.54.140
for Live/work dwelling units (1, 2, 3, 4+ units)
1 × bedrooms in the whole project spaces SMC 16.54.140
for Boarding houses (group living)
1 space per bed SMC 16.54.140
for Residential care facilities (group living)
0.25 spaces per sleeping unit SMC 16.54.140
for Co-living housing (group living)
0 spaces per bed SMC 16.54.140; 16.68.020(C)(4)(a)-(c)
for Emergency shelters (group living); Emergency housing (group living)
1.25 × employees on the largest shift spaces SMC 16.54.140; 16.68.010(C)(3)(a)-(c)
for Transitional housing (group living)2; Transitional housing (group living)3; Transitional housing (group living)4; Permanent supportive housing (group living)2; Permanent supportive housing (group living)3; Permanent supportive housing (group living)4

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SMC 16.12.005(F)(1)(a)-(b); 16.36.150
1 unit SMC 16.12.005(F)(1)(a)-(b); 16.36.150
for Duplexes/two-family dwellings (2 units)

Building

StandardValueExceptions
Front setbackFront yard setbacks for accessory dwelling units are 10 feet behind the primary structure unless a conversion of existing structure or a vertical addition to an existing garage that does not add to the existing footprint of the primary unit or its garage. SMC 16.12.005(F)(1)(d); 16.36.160(A)
Side setback10 ft SMC 16.36.160(A)
Rear setback5 ft SMC 16.36.160(A)
Maximum height24 ft SMC 16.36.160(A); 16.12.050(F)
Minimum parking1 space per unit SMC 16.54.140
Maximum unit size1,000 sq ft SMC 16.12.005(F)(1)(c); 16.36.160(A)
Attached to the main houseNot required SMC 16.36.150

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 19.12.050; 19.24.020(B) A up to 9 SMC 19.12.010; 19.04.020(A)(44) —
Minimum lot size
Not set SMC 19.14.050(A)
Minimum lot width
Not set SMC 19.14.050(A)
Minimum frontage
20 ft SMC 16.04.010.3
Subdivision SMC 19.06.060(A); 19.08.030; 19.26.020 H 10 or more SMC 19.06.020; 19.04.020(A)(49) —
Minimum lot size
Not set SMC 19.08.080(A)(2)
Minimum lot width
Not set SMC 19.08.080(A)(2)
Minimum frontage
20 ft SMC 16.04.010.3
Unit lot subdivision SMC 19.12.010; 19.14.110(A)(2); 19.24.020(B)Only for: Duplexes/two-family dwellings, Townhouses, Apartments/multifamily dwellings A 2 to 9 SMC 19.04.020(A)(51); SMC 19.14.110(A)(3) —
Minimum lot size
A unit lot may be as small as the footprint of the structure it contains, provided it meets applicable building, fire, and utility code requirements. SMC 19.14.110(B)(5)
Minimum lot width
Not set SMC 19.14.110(B)
Minimum frontage
Not set SMC 19.14.110(B)(3)
Binding site plan, small-scale SMC 19.18.020; 19.18.040; 19.24.020(A) A 2 to 9 SMC 19.18.010; SMC 19.04.020(A)(6) —
Minimum lot size
Not set SMC 19.18.110; 19.18.020
Minimum lot width
Not set SMC 19.18.110; 19.18.020
Minimum frontage
Not set SMC 19.18.110; 19.18.020
Binding site plan, large-scale SMC 19.18.020; 19.18.050 H 10 or more SMC 19.04.020(A)(7) —
Minimum lot size
Not set SMC 19.18.110; 19.18.020
Minimum lot width
Not set SMC 19.18.110; 19.18.020
Minimum frontage
Not set SMC 19.18.110; 19.18.020

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The residential space has a significant, physical connection to the commercial building it is accessory to
    • The apartment connects to public water and sewer service
    • It is the only accessory apartment for an established business on the site (one apartment per established business, so long as the site does not exceed the maximum density)
    • The building is approved by the building official as a legal, permanent structure
  2. The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is detached
  3. The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is attached
  4. The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is stacked
  5. None of these is true:
    • The lot is an existing lot, not a lot created by a new division
  6. The lot is an existing lot, not a lot created by a new division
  7. Bedrooms in one unit is at most 1
  8. Bedrooms in one unit is more than 1