Sign in

High Density Residential · High density residential district (HDR)

Sumner, WA · SMC 18.14 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Zero lot line detached dwelling
Home✓ ADU—
————
Duplex—
Home✓ ADU—
———
Townhouse—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Zero lot line dwelling—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Multiplex——
Home✓ ADU—
Home✓ ADU—
—
Apartments——
Home✓ ADU—
Home✓ ADU—
—
Cottage houses or housing———
Home✓ ADU—
—
Manufactured home park———
HomeH ADU—
—
Senior housing———
HomeH1 ADU—
—
Affordable multifamily housing on properties owned by a religious organization———
HomeH2 ADU—
—
Group home, small————
Home✓ ADU—
Group home, large————
Home✓ ADU—
Co-living housing————
Home✓ ADU—
Home for the aged————
HomeH ADU—
Assisted living facilities————
HomeH ADU—
Board and care homes————
HomeH ADU—
Hospice————
HomeH ADU—
Nursing home, convalescent home————
HomeH ADU—
Lodging houses————
HomeH ADU—
Permanent supportive housing————
HomeH3 ADU—
Transitional housing————
HomeH3 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set SMC 18.14.070
4 units SMC 18.14.020(O); 18.04.0725
for Multiplex (4+ units)
lot area ÷ 4,800, rounded down units SMC 18.34.050(C); 18.34.060(A)
for Manufactured home park (4+ units)
Minimum unitsNot set SMC 18.14.070
3 units SMC 18.04.0725
for Multiplex (4+ units)
4 units SMC 18.04.0303
for Cottage houses or housing (4+ units)
Minimum lot size5,000 sq ft SMC 18.14.070(A)
3,000 sq ft SMC 18.14.070(A)
for Zero lot line detached dwelling (1 unit)
Minimum lot area for zero lot line dwellings (per dwelling) | N/A3 SMC 18.14.070(A)
for Zero lot line dwelling (2, 3, 4+ units)
Minimum lot width50 ft SMC 18.14.070(D)
30 ft SMC 18.14.070(D)
for Zero lot line detached dwelling (1 unit)
For zero lot line lots, the lot width and frontage may be as wide as the minimum required unit width, provided that the unit complies with building code, landscaping and open space requirements. SMC 18.14.070(fn3)
for Zero lot line dwelling (2, 3, 4+ units)
Minimum frontage30 ft SMC 18.14.070(L)
For zero lot line lots, the lot width and frontage may be as wide as the minimum required unit width, provided that the unit complies with building code, landscaping and open space requirements. SMC 18.14.070(fn3)
for Zero lot line dwelling (2, 3, 4+ units)
Maximum density25 units per acre, on the net lot area SMC 18.14.070(C)
1 unit per 4,800 sq ft SMC 18.34.050(C)
for Manufactured home park (4+ units)
50 units per acre SMC 18.24.060(D)(2)(b)
for Senior housing (4+ units)1; Affordable multifamily housing on properties owned by a religious organization (4+ units)2
Minimum development sizeNot set SMC 18.14.070
21,780 sq ft SMC 18.24.060(A)(4)
for Affordable multifamily housing on properties owned by a religious organization (4+ units)2
Maximum residentsNot set SMC 18.14.070
8 persons SMC 18.04.0455
for Group home, small (group living)
Comply with the maximum housing density for the zone and occupancy limits set by the city fire code; and SMC 18.14.080(P)(2)
for Permanent supportive housing (group living)3; Transitional housing (group living)3
Maximum sleeping unitsNot set SMC 18.14.070
4 × ((25 × lot area minus critical areas and buffers) ÷ 43,560, rounded down) sleeping units SMC 18.14.070(C); 18.14.080(Q)(4)
for Co-living housing (group living)

3. Building standards

StandardValueExceptions
Front setback10 ft SMC 18.14.070(E)(1)
Not read SMC 18.40.040
for Townhouse (2, 3, 4+ units); Multiplex (3, 4+ units); Apartments (3, 4+ units); Cottage houses or housing (4+ units)
Side setback5 ft SMC 18.14.070(E)(3)
0 ft SMC 18.14.070(E)(4)
for Zero lot line detached dwelling (1 unit); Zero lot line dwelling (2, 3, 4+ units)
Not read SMC 18.40.040
for Townhouse (2, 3, 4+ units); Multiplex (3, 4+ units); Apartments (3, 4+ units); Cottage houses or housing (4+ units)
Street side setback10 ft SMC 18.14.070(G)
Rear setback20 ft SMC 18.14.070(E)(2)
Not read SMC 18.40.040
for Townhouse (2, 3, 4+ units); Multiplex (3, 4+ units); Apartments (3, 4+ units); Cottage houses or housing (4+ units)
15 ft SMC 18.14.070(H)(2)
for Zero lot line dwelling (2, 3, 4+ units)
Maximum height35 ft SMC 18.14.070(I)
50 ft SMC 18.24.060(E)(2)
for Senior housing (4+ units)1; Affordable multifamily housing on properties owned by a religious organization (4+ units)2
Maximum storiesNot set SMC 18.14.070
3 stories SMC 18.14.020(N)
for Apartments (3, 4+ units)
Maximum lot coverage45% SMC 18.14.070(J)
Minimum parkingIn the case of a use not specifically mentioned in this chapter the requirements for off-street parking facilities shall be determined by the director. SMC 18.42.090
2 + (1 ÷ 4) spaces per unit SMC 17.28.340(E)(1); 17.28.340(E)(3); 18.14.060(B)
for Zero lot line detached dwelling (1 unit); Zero lot line dwelling (2, 3, 4+ units)
  • 1 + (1 ÷ 5) spaces per unit4 SMC 18.42.040(B)(1)
  • 1.5 + (1 ÷ 5) spaces per unit5 SMC 18.42.040(B)(1)
  • 2 + (1 ÷ 5) spaces per unit6 SMC 18.42.040(B)(1)
for Townhouse (2, 3, 4+ units); Multiplex (3, 4+ units); Apartments (3, 4+ units); Cottage houses or housing (4+ units); Affordable multifamily housing on properties owned by a religious organization (4+ units)2
(2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5) spaces SMC 18.42.040(S)
for Manufactured home park (4+ units)
main dwelling units on the lot + (main dwelling units on the lot ÷ 7) + employees on the largest shift spaces SMC 18.42.040(B)(2)
for Senior housing (4+ units)1
  • 1 ÷ 4 spaces per sleeping unit7 SMC 18.42.040(B)(3)
  • 0 spaces per sleeping unit8 SMC 18.42.040(V)
for Co-living housing (group living)
(beds in the project ÷ 6) + employees on the largest shift spaces SMC 18.42.040(E)
for Nursing home, convalescent home (group living)
Maximum unit sizeNot set SMC 18.14.070
300 sq ft SMC 18.14.080(Q)(1)(a)
for Co-living housing (group living)
Maximum lot sizeNot set SMC 18.14.070
6,000 sq ft SMC 18.14.070(B)
for Zero lot line detached dwelling (1 unit)
Minimum open spaceNot set SMC 18.14.070
20% SMC 18.24.060(F)(3)
for Senior housing (4+ units)1; Affordable multifamily housing on properties owned by a religious organization (4+ units)2
Maximum units per buildingNot set SMC 18.14.070
6 units SMC 18.14.070(O)
for Zero lot line dwelling (2, 3, 4+ units)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Lot line adjustment SMC 17.08.040(C); 18.56.030(B)(3) ✓
Maximum lots
the relocation does not result in the creation of any additional lot or lots SMC 17.04.060
—
Minimum lot size
5,000 sq ft SMC 18.14.070(A)
Minimum lot width
50 ft SMC 18.14.070(D)
Minimum frontage
30 ft SMC 18.14.070(L)
Planned residential development (PRD) SMC 18.56.030(I)(6); 18.24.020(A) H —
Minimum parent area
Not set SMC 18.24.060(A)
Minimum lot size
The minimum lot size, lot coverage and yard requirements of other sections of this title may be adjusted or waived within the planned residential development SMC 18.24.060(B)
Subdivision, short SMC 18.56.030(D)(1); 18.56.030(G)(4) A up to 9 SMC 17.04.040(A); 17.12.030 —
Minimum lot size
5,000 sq ft SMC 18.14.070(A)
Minimum lot width
50 ft SMC 18.14.070(D)
Minimum frontage
30 ft SMC 18.14.070(L)
Subdivision, full SMC 18.56.030(I)(3); 17.16.040(A) H 10 or more SMC 17.04.040(A) —
Minimum lot size
5,000 sq ft SMC 18.14.070(A)
Minimum lot width
50 ft SMC 18.14.070(D)
Minimum frontage
30 ft SMC 18.14.070(L)
Zero lot line subdivision SMC 17.28.340(A); 18.56.030(I)(3)Only for: Zero lot line dwelling, Zero lot line detached dwelling H 10 or more SMC 17.04.040(A) —
Minimum lot size
Zero lot line lot area and lot width per lot for purposes of subdivision may be as small as the minimum lot area and lot width specified in SMC § 18.14.070 plus any required private open space. SMC 17.28.340(C)
Maximum units per lot
1 unit SMC 17.28.340(B)
Zero lot line short subdivision SMC 17.28.340(A); 18.56.030(D)(1); 18.56.030(G)(4)Only for: Zero lot line dwelling, Zero lot line detached dwelling A up to 9 SMC 17.04.040(A); 17.12.030 —
Minimum lot size
Zero lot line lot area and lot width per lot for purposes of subdivision may be as small as the minimum lot area and lot width specified in SMC § 18.14.070 plus any required private open space. SMC 17.28.340(C)
Maximum units per lot
1 unit SMC 17.28.340(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Use is approved through a planned residential development pursuant to chapter 18.24 SMC
  2. All of these are true:
    • Property is owned by a religious organization
    • Use is approved through a planned residential development pursuant to chapter 18.24 SMC
  3. Site is not within 880 feet of any other emergency shelter, emergency housing, permanent supportive housing or transitional housing use
  4. Bedrooms in one unit is less than 1
  5. All of these are true:
    • Bedrooms in one unit is at least 1
    • Bedrooms in one unit is at most 2
  6. Bedrooms in one unit is at least 3
  7. None of these is true:
    • Within one-half mile walking distance of a major transit stop
  8. Within one-half mile walking distance of a major transit stop