Sign in

Neigborhood Commercial · Neighborhood commercial district (NC)

Sumner, WA · SMC 18.16 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Multifamily dwellings——
Home✓1 ADU—
Home✓1 ADU—
—
Senior apartments——
Home✓2 ADU—
Home✓2 ADU—
—
Retirement home——
Home✓2 ADU—
Home✓2 ADU—
—
Multifamily residential infill dwellings (MRI)——
Home✓3 ADU—
Home✓3 ADU—
—
Continuing care or life care communities———
Home✓2 ADU—
—
Senior housing———
HomeH4 ADU—
—
Affordable multifamily housing on properties owned by a religious organization———
HomeH5 ADU—
—
Group home, large————
Home✓ ADU—
Co-living housing————
Home✓1 ADU—
Assisted living facilities————
Home✓ ADU—
Board and care homes————
Home✓ ADU—
Hospice————
Home✓ ADU—
Nursing home, convalescent home————
Home✓ ADU—
Permanent supportive housing————
HomeH6 ADU—
Transitional housing————
HomeH6 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size4,500 sq ft SMC 18.16.070(1)
Minimum lot width50 ft SMC 18.16.070(2)
Minimum lot depth100 ft SMC 18.16.070(3)
Minimum frontage35 ft SMC 18.16.070(9)
Maximum density25 units per acre, on the net lot area SMC 18.16.040(C)
1.5 × 25 units per acre, on the net lot area SMC 18.16.040(F)(1)(c); 18.16.040(C)
for Multifamily residential infill dwellings (MRI) (3, 4+ units)3
50 units per acre SMC 18.24.060(D)(2)(c)
for Senior housing (4+ units)4; Affordable multifamily housing on properties owned by a religious organization (4+ units)5
Not set SMC 18.16.070
for Group home, large (group living); Co-living housing (group living)1; Assisted living facilities (group living); Board and care homes (group living); Hospice (group living); Nursing home, convalescent home (group living)
Minimum development sizeNot set SMC 18.16.070
21,780 sq ft SMC 18.24.060(A)(4)
for Affordable multifamily housing on properties owned by a religious organization (4+ units)5
Maximum residentsNot set SMC 18.16.070
Comply with the maximum residential density and mixed use requirements for the zone as specified in SMC § 18.16.040 and occupancy limits set by the city fire code; and SMC 18.16.080(X)(2)
for Permanent supportive housing (group living)6; Transitional housing (group living)6
Maximum sleeping unitsNot set SMC 18.16.070
4 × ((25 × lot area minus critical areas and buffers) ÷ 43,560, rounded down) sleeping units SMC 18.16.040(C); 18.14.080(Q)(4)
for Co-living housing (group living)1

3. Building standards

StandardValueExceptions
Front setback0 ft SMC 18.16.070(4)
Maximum front setback25 ft SMC 18.16.070(4)
Side setback
  • 10 ft7 SMC 18.16.070(6)(a)
  • 0 ft8 SMC 18.16.070(6)(b)
Street side setback
  • 10 ft7 SMC 18.16.070(7)(a)
  • 0 ft8 SMC 18.16.070(7)(b)
Rear setback20 ft SMC 18.16.070(5)
Maximum height35 ft SMC 18.16.070(11)
50 ft SMC 18.24.060(E)(3)
for Senior housing (4+ units)4; Affordable multifamily housing on properties owned by a religious organization (4+ units)5
Maximum lot coverage75% SMC 18.16.070(10)
Minimum parkingIn the case of a use not specifically mentioned in this chapter the requirements for off-street parking facilities shall be determined by the director. SMC 18.42.090
  • 1 + (1 ÷ 5) spaces per unit9 SMC 18.42.040(B)(1)
  • 1.5 + (1 ÷ 5) spaces per unit10 SMC 18.42.040(B)(1)
  • 2 + (1 ÷ 5) spaces per unit11 SMC 18.42.040(B)(1)
for Multifamily dwellings (3, 4+ units)1; Continuing care or life care communities (4+ units)2; Affordable multifamily housing on properties owned by a religious organization (4+ units)5
main dwelling units on the lot + (main dwelling units on the lot ÷ 7) + employees on the largest shift spaces SMC 18.42.040(B)(2)
for Senior apartments (3, 4+ units)2; Retirement home (3, 4+ units)2; Senior housing (4+ units)4
0 spaces per unit SMC 18.16.040(F)(2)(a)
for Multifamily residential infill dwellings (MRI) (3, 4+ units)3
  • 1 ÷ 4 spaces per sleeping unit12 SMC 18.42.040(B)(3)
  • 0 spaces per sleeping unit13 SMC 18.42.040(V)
for Co-living housing (group living)1
(beds in the project ÷ 6) + employees on the largest shift spaces SMC 18.42.040(E)
for Nursing home, convalescent home (group living)
Maximum unit sizeNot set SMC 18.16.070
300 sq ft SMC 18.14.080(Q)(1)(a)
for Co-living housing (group living)1
Minimum open spaceNot set SMC 18.16.070
20% SMC 18.24.060(F)(3)
for Senior housing (4+ units)4; Affordable multifamily housing on properties owned by a religious organization (4+ units)5

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Lot line adjustment SMC 17.08.040(C); 18.56.030(B)(3) ✓
Maximum lots
the relocation does not result in the creation of any additional lot or lots SMC 17.04.060
—
Minimum lot size
4,500 sq ft SMC 18.16.070(1)
Minimum lot width
50 ft SMC 18.16.070(2)
Minimum lot depth
100 ft SMC 18.16.070(3)
Minimum frontage
35 ft SMC 18.16.070(9)
Subdivision, short SMC 18.56.030(D)(1); 18.56.030(G)(4) A up to 9 SMC 17.04.040(A); 17.12.030 —
Minimum lot size
4,500 sq ft SMC 18.16.070(1)
Minimum lot width
50 ft SMC 18.16.070(2)
Minimum lot depth
100 ft SMC 18.16.070(3)
Minimum frontage
35 ft SMC 18.16.070(9)
Subdivision, full SMC 18.56.030(I)(3); 17.16.040(A) H 10 or more SMC 17.04.040(A) —
Minimum lot size
4,500 sq ft SMC 18.16.070(1)
Minimum lot width
50 ft SMC 18.16.070(2)
Minimum lot depth
100 ft SMC 18.16.070(3)
Minimum frontage
35 ft SMC 18.16.070(9)
Binding site plan SMC 18.56.030(I)(4); 17.26.020(A) H
Maximum lots
Not set SMC 17.26
—
Minimum lot size
4,500 sq ft SMC 18.16.070(1)
Minimum lot width
50 ft SMC 18.16.070(2)
Minimum lot depth
100 ft SMC 18.16.070(3)
Minimum frontage
35 ft SMC 18.16.070(9)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Residential floor area is above first-story commercial uses
  2. Units are occupied by residents aged 55 or older (senior housing)
  3. All of these are true:
    • Units are located within the current building envelope of an existing commercial or mixed-use building
    • The building received a certificate of occupancy a minimum of three years prior to the MRI permit application
    None of these is true:
    • Units are located within spaces that are dedicated or required by this code for commercial development
    • Units are located within spaces that will remain dedicated or required for parking by this code
  4. All of these are true:
    • Units are occupied by residents aged 55 or older (senior housing)
    • Use is approved through a planned residential development pursuant to chapter 18.24 SMC
  5. All of these are true:
    • Property is owned by a religious organization
    • Use is approved through a planned residential development pursuant to chapter 18.24 SMC
  6. Site is not within 880 feet of any other emergency shelter, emergency housing, permanent supportive housing or transitional housing use
  7. None of these is true:
    • Lot is in the NC zone along Main Street west of Valley Avenue
  8. Lot is in the NC zone along Main Street west of Valley Avenue
  9. Bedrooms in one unit is less than 1
  10. All of these are true:
    • Bedrooms in one unit is at least 1
    • Bedrooms in one unit is at most 2
  11. Bedrooms in one unit is at least 3
  12. None of these is true:
    • Within one-half mile walking distance of a major transit stop
  13. Within one-half mile walking distance of a major transit stop