P-B · Professional Business
Sunnyside, WA · SMC 17.36 · Official code
By right: 1 unit, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, one-family | — | — | — | — | |
| Zero lot line development | Home✓ ADU— | — | — | — | — |
| Dwelling, two-family | — | — | — | — | |
| Dwelling, multiple | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Apartment house | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Group residential facility | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 4,300 sq ft SMC 17.36.030(A); 17.16.030(A) | |
| Minimum lot width | 50 ft SMC 17.36.030(A); 17.16.030(B) | |
| Minimum density | Not set SMC 17.36.030 | 1 units per acre SMC 17.36.020(J); 17.16.010
for Dwelling, multiple (3, 4+ units); Apartment house (3, 4+ units) |
| Maximum density | Not set SMC 17.36.030 | 16 units per acre SMC 17.36.020(J); 17.16.010; 17.16.020(A)(2)
for Dwelling, multiple (3, 4+ units); Apartment house (3, 4+ units) |
| Maximum residents | 8 persons SMC 17.04.030 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft SMC 17.36.040(A); 17.16.040(A) | |
| Side setback | 5 ft SMC 17.36.040(A); 17.16.040(B) | |
| Street side setback | 20 ft SMC 17.36.040(A); 17.16.040(B) | |
| Rear setback | 15 ft SMC 17.36.040(A); 17.16.040(C) | |
| Maximum height | 35 ft SMC 17.36.030(A); 17.16.030(C) | |
| Maximum stories | 2 stories SMC 17.36.030(A); 17.16.030(C) | |
| Maximum lot coverage | 55% SMC 17.36.030(A); 17.16.030(D) | |
| Minimum parking | 2 spaces per unit SMC 17.64.040(T) | 1 space per unit SMC 17.64.040(A)
for Dwelling, multiple (4+ units); Apartment house (4+ units) Parking requirements for any specific occupancy or use not listed in this section will be determined in accordance with the use most closely related to such proposed use as determined by City staff. SMC 17.64.040
for Group residential facility (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit SMC 17.64.015(B)(6) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | 35 ft SMC 17.36.030(A); 17.16.030(C) | |
| Maximum stories | 2 stories SMC 17.36.030(A); 17.16.030(C) | |
| Minimum parking | 1 space per unit SMC 17.64.040(V); 17.64.015(B)(2) | |
| Maximum unit size | 1,000 sq ft SMC 17.64.015(B)(3) | |
| Attached to the main house | Not required SMC 17.64.015(B)(1) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 16.04.030(A); 16.04.090 | A | up to 9 SMC 16.24.300; 16.04.010(K) | — | Minimum lot size Each lot within a subdivision shall comply with the lot size and width requirements of the zoning ordinance. SMC 16.32.030 Minimum lot width Each lot within a subdivision shall comply with the lot size and width requirements of the zoning ordinance. SMC 16.32.030 Minimum lot depth Not set SMC 16.32.040 Minimum frontage Minimum street frontage shall comply with the lot size and width requirements of the zoning code, except for lots located within the arc of a curve or where unusual topography exists a minimum frontage of 40 feet is allowed. SMC 16.32.040(B) Maximum units per lot Not set SMC 16.32 |
| Subdivision SMC 16.28.070; 16.28.110; 16.28.120 | H | 10 or more SMC 16.24.330; 16.24.300 | — | Minimum lot size Each lot within a subdivision shall comply with the lot size and width requirements of the zoning ordinance. SMC 16.32.030 Minimum lot width Each lot within a subdivision shall comply with the lot size and width requirements of the zoning ordinance. SMC 16.32.030 Minimum lot depth Not set SMC 16.32.040 Minimum frontage Minimum street frontage shall comply with the lot size and width requirements of the zoning code, except for lots located within the arc of a curve or where unusual topography exists a minimum frontage of 40 feet is allowed. SMC 16.32.040(B) Maximum units per lot Not set SMC 16.32 |
| Binding site plan SMC 16.06.070 | A | Maximum lots Not set SMC 16.06 |
— | Minimum lot size The lot(s) meet the minimum lot size in the zoning district. SMC 16.06.100(C) Minimum lot width Not set SMC 16.06 Minimum lot depth Not set SMC 16.06 Minimum frontage Not set SMC 16.06 Maximum units per lot Not set SMC 16.06 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The lot is an existing lot
- Lot area is at most 11,000 sf
- The lot line is the line of a lot not approved for zero lot line development
- All of these are true:
- The side lot line is the zero lot line shown on the plat
- The lot line is the line of a lot not approved for zero lot line development
- None of these is true:
- The lot line is the line of a lot not approved for zero lot line development
- The side lot line is the zero lot line shown on the plat
- None of these is true:
- The ADU is attached to or built above a detached garage, or is a stand-alone structure (not attached to the primary structure)
- The ADU is attached to or built above a detached garage, or is a stand-alone structure (not attached to the primary structure)