R-2 · Medium Density Residential
Sunnyside, WA · SMC 17.16 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, one-family | Home✓ ADU✓ | — | — | — | — |
| Zero lot line development | Home✓ ADU— | — | — | — | — |
| Manufactured home | — | — | — | — | |
| Dwelling, two-family | — | Home✓ ADU— | — | — | — |
| Dwelling, multiple | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Apartment house | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Group residential facility | — | — | — | — | HomeH ADU— |
| Convalescent, nursing, retirement homes | — | — | — | — | HomeH ADU— |
| Charitable institutions and orphanages | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 4,300 sq ft SMC 17.16.030(A) | |
| Minimum lot width | 50 ft SMC 17.16.030(B) | |
| Minimum density | 1 units per acre SMC 17.16.010 | Not set SMC 17.16.030
for Group residential facility (group living); Convalescent, nursing, retirement homes (group living); Charitable institutions and orphanages (group living) |
| Maximum density | 9 units per acre SMC 17.16.010 | 16 units per acre SMC 17.16.010
for Dwelling, multiple (3, 4+ units); Apartment house (3, 4+ units) Not set SMC 17.16.030
for Group residential facility (group living); Convalescent, nursing, retirement homes (group living); Charitable institutions and orphanages (group living) |
| Maximum residents | Not set SMC 17.64.020(B) | 8 persons SMC 17.04.030
for Group residential facility (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft SMC 17.16.040(A) | |
| Side setback | 5 ft SMC 17.16.040(B) | |
| Street side setback | 20 ft SMC 17.16.040(B) | |
| Rear setback | 15 ft SMC 17.16.040(C) | |
| Maximum height | 35 ft SMC 17.16.030(C) | |
| Maximum stories | 2 stories SMC 17.16.030(C) | |
| Maximum lot coverage | 55% SMC 17.16.030(D) | |
| Minimum parking | 2 spaces per unit SMC 17.64.040(T) | 1 space per unit SMC 17.64.040(A)
for Dwelling, multiple (4+ units); Apartment house (4+ units) Parking requirements for any specific occupancy or use not listed in this section will be determined in accordance with the use most closely related to such proposed use as determined by City staff. SMC 17.64.040
for Group residential facility (group living); Charitable institutions and orphanages (group living) the largest of 2, (beds in the project ÷ 5) + (employees on the largest shift ÷ 2) spaces SMC 17.64.040(E)
for Convalescent, nursing, retirement homes (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit SMC 17.64.015(B)(6) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | 35 ft SMC 17.16.030(C) | |
| Maximum stories | 2 stories SMC 17.16.030(C) | |
| Minimum parking | 1 space per unit SMC 17.64.040(V); 17.64.015(B)(2) | |
| Maximum unit size | 1,000 sq ft SMC 17.64.015(B)(3) | |
| Attached to the main house | Not required SMC 17.64.015(B)(1) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 16.04.030(A); 16.04.090 | A | up to 9 SMC 16.24.300; 16.04.010(K) | — | Minimum lot size 4,300 sq ft SMC 17.16.030(A) Minimum lot width 50 ft SMC 17.16.030(B) Minimum lot depth Not set SMC 16.32.040 Maximum units per lot Not set SMC 16.32 |
| Subdivision SMC 16.28.070; 16.28.110; 16.28.120 | H | 10 or more SMC 16.24.330; 16.24.300 | — | Minimum lot size 4,300 sq ft SMC 17.16.030(A) Minimum lot width 50 ft SMC 17.16.030(B) Minimum lot depth Not set SMC 16.32.040 Maximum units per lot Not set SMC 16.32 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The manufactured home is placed permanently on a lot with a foundation built to conventional construction requirements
- The manufactured home is designated as real property and taxed as real property
- Floor area of the main house is at least 950
- The manufactured home is built to federal manufactured home construction and safety standards, with an affixed certification label (24 CFR 3280.8)
- The manufactured home meets any other requirements to be eligible for FHA mortgage insurance (Title II)
- The manufactured home is new or not previously occupied
- The lot line is the line of a lot not approved for zero lot line development
- All of these are true:
- The side lot line is the zero lot line shown on the plat
- The lot line is the line of a lot not approved for zero lot line development
- None of these is true:
- The lot line is the line of a lot not approved for zero lot line development
- The side lot line is the zero lot line shown on the plat
- None of these is true:
- The ADU is attached to or built above a detached garage, or is a stand-alone structure (not attached to the primary structure)
- The ADU is attached to or built above a detached garage, or is a stand-alone structure (not attached to the primary structure)
- The lot is within the arc of a curve or has unusual topography
- None of these is true:
- The lot is within the arc of a curve or has unusual topography