Sign in

HMX · Hospital Medical Mixed-Use District

Tacoma, WA · TMC 13.06.040 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, single-unit detached
Home✓ ADU✓
————
Dwelling, townhouse
Home✓ ADU✓
————
Live/Work
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Work/Live
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Dwelling, two-unit—
Home✓ ADU✓
———
Dwelling, three-unit——
Home✓ ADU✓
——
Dwelling, multi-unit———
Home✓ ADU✓
—
Retirement home———
Home✓ ADU✓
—
Group housing————
Home✓ ADU✓
Special needs housing————
Home✓ ADU✓
Permanent shelter————
Home✓ ADU✓
Confidential shelter————
Home✓ ADU✓
Temporary shelter————
Home✓1 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set TMC 13.06.040E.3
20 units TMC 13.06.040E.3
for Live/Work (4+ units); Work/Live (4+ units)
Minimum unitsNot set TMC 13.06.040E.3
4 units TMC 13.01.060
for Dwelling, multi-unit (4+ units)
Minimum lot size0 sq ft TMC 13.06.040F.1.c
Minimum lot width0 ft TMC 13.06.040F.1.d
Minimum densityNo limit TMC 13.06.040F.5.c
Maximum residentsNot set TMC 13.06.040E.3
the smallest of 100, lot area ÷ 150, rounded down persons TMC 13.06.080N.3.d(1); 13.06.080N.3.d(2)
for Temporary shelter (group living)1

3. Building standards

StandardValueExceptions
Front setback
  • 0 ft2 TMC 13.06.040F.1.e
  • 10 ft3 TMC 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.040F.1.e
Maximum front setback
  • 20 ft5 TMC 13.06.040H
  • Not set6 TMC 13.06.040H
Side setback
  • 0 ft7 TMC 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.040F.1.e
  • 5 ft7 TMC 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.040F.1.e
for Dwelling, townhouse (1 unit)
Rear setback
  • 0 ft7 TMC 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.040F.1.e
  • 5 ft7 TMC 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.040F.1.e
for Dwelling, townhouse (1 unit)
Building separation
  • 6 ft8 TMC 13.06.010H.4.a(2)
  • 10 ft9 TMC 13.06.010H.4.a(2)
  • 10 + (building stories − 6, rounded up) ft10 TMC 13.06.010H.4.a(3)
  • 10 + (2 × (building stories − 6, rounded up)) ft11 TMC 13.06.010H.4.a(3)
Maximum height150 ft TMC 13.06.040F.2.c
Minimum parking
  • 0 spaces per unit12 TMC 13.06.090C.4.a(4)
  • 1 space per unit13 TMC 13.06.090C.3.l(2)
0 spaces per sleeping unit TMC 13.06.090C.3.l(3)(d)
for Group housing (group living)
0.7 × ((0.1 × beds in the project) + employees on the largest shift) spaces TMC 13.06.090C.3.l(2); 13.06.090C.3 Table 1
for Special needs housing (group living); Permanent shelter (group living); Confidential shelter (group living); Temporary shelter (group living)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units TMC 13.06.080A.4.a
Minimum lot sizeNo limit TMC 13.06.080A.5.a

Building

StandardValueExceptions
Front setback
  • 0 ft2 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • 10 ft3 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.080A.5.d; 13.06.040F.1.e
Side setback
  • 0 ft7 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • 5 ft7 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.080A.5.d; 13.06.040F.1.e
for Dwelling, townhouse (1 unit)
Rear setback
  • 0 ft7 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • 5 ft7 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.080A.5.d; 13.06.040F.1.e
for Dwelling, townhouse (1 unit)
Maximum height150 ft TMC 13.06.080A.5.c; 13.06.040F.2.c
Minimum parking0 spaces per unit TMC 13.06.080A.4.d
Maximum unit size1,000 sq ft TMC 13.06.080A.5.b(1)
Attached to the main houseNot required TMC 13.06.080A.5.a

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision TMC 13.05.070H Table H; 13.04.090A A 2 to 9 TMC 13.05.070H Table H; TMC 13.01.040 —
Minimum lot size
0 sq ft TMC 13.06.040F.1.c
Minimum lot width
0 ft TMC 13.06.040F.1.d
Subdivision TMC 13.05.110B; 13.05.070H Table H H 10 or more TMC 13.01.040 —
Minimum lot size
0 sq ft TMC 13.06.040F.1.c
Minimum lot width
0 ft TMC 13.06.040F.1.d
Binding site plan TMC 13.05.070H Table H; 13.04.088BOnly for: Dwelling, multi-unit A
Minimum lots
Not set TMC 13.04.088
—
Minimum lot size
Not set TMC 13.04.088

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The site is in a critical area or its buffer
  2. None of these is true:
    • The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
    • The X District property is across a non-designated Pedestrian Street from UR-1, UR-2 or UR-3 District property
  3. All of these are true:
    • The X District property is across a non-designated Pedestrian Street from UR-1, UR-2 or UR-3 District property
    None of these is true:
    • The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
  4. The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
  5. The lot abuts a designated pedestrian street (TMC 13.06.010D)
  6. None of these is true:
    • The lot abuts a designated pedestrian street (TMC 13.06.010D)
  7. None of these is true:
    • The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
  8. All of these are true:
    • Building height is at most 25
    • Building stories is at most 6
  9. All of these are true:
    • Building height is more than 25
    • Building stories is at most 6
  10. All of these are true:
    • Building stories is more than 6
    None of these is true:
    • Another building on the same site, adjacent to this one, also exceeds six stories
  11. All of these are true:
    • Building stories is more than 6
    • Another building on the same site, adjacent to this one, also exceeds six stories
  12. The project is mixed-use with at least 50 percent of the floor area designed for commercial or institutional use
  13. It is not true that the project is mixed-use with at least 50 percent of the floor area designed for commercial or institutional use