Sign in

STT · Seaport Transition - Transit Oriented Development District

Tacoma, WA · TMC 13.06.060 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Work/Live
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Multiplex———
Home✓ ADU—
—
Retirement home———
Home✓ ADU—
—
Group housing————
HomeA ADU—
Special needs housing————
HomeA ADU—
Permanent shelter————
Home✓ ADU—
Temporary Worker Housing————
Home✓ ADU—
Temporary shelter————
Home✓1 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set TMC 13.06.060E.6
20 units TMC 13.06.060E.6
for Work/Live (4+ units)
Minimum unitsNot set TMC 13.06.060E.6
7 units TMC 13.01.060
for Multiplex (4+ units)
Maximum residentsNot set TMC 13.06.060F
the smallest of 100, lot area ÷ 150, rounded down persons TMC 13.06.080N.3.d(1); 13.06.080N.3.d(2)
for Temporary shelter (group living)1

3. Building standards

StandardValueExceptions
Front setback
  • 0 ft2 TMC 13.06.060H.2; 13.06.040F.1.e
  • 10 ft3 TMC 13.06.060H.2; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.060H.2; 13.06.040F.1.e
Maximum front setback
  • 20 ft5 TMC 13.06.060H.2; 13.06.040H
  • Not set6 TMC 13.06.060H.2; 13.06.040H
Side setback
  • 0 ft7 TMC 13.06.060H.2; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.060H.2; 13.06.040F.1.e
Rear setback
  • 0 ft7 TMC 13.06.060H.2; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side4 TMC 13.06.060H.2; 13.06.040F.1.e
Building separation
  • 6 ft8 TMC 13.06.010H.4.a(2)
  • 10 ft9 TMC 13.06.010H.4.a(2)
  • 10 + (building stories − 6, rounded up) ft10 TMC 13.06.010H.4.a(3)
  • 10 + (2 × (building stories − 6, rounded up)) ft11 TMC 13.06.010H.4.a(3)
Maximum height100 ft TMC 13.06.060F.7
Maximum lot coverage85% TMC 13.06.060F.3
Minimum parking0 spaces per unit TMC 13.06.090C.3 Table 2 note 20
Minimum open space10% TMC 13.06.060G.8; 13.06.090B.4.d(2)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision TMC 13.05.070H Table H; 13.04.090A A 2 to 9 TMC 13.05.070H Table H; TMC 13.01.040 —
Minimum lot size
Not set TMC 13.06.060F.1
Subdivision TMC 13.05.110B; 13.05.070H Table H H 10 or more TMC 13.01.040 —
Minimum lot size
Not set TMC 13.06.060F.1
Binding site plan TMC 13.05.070H Table H; 13.04.088BOnly for: Multiplex, Retirement home, Work/Live A
Minimum lots
Not set TMC 13.04.088
—
Minimum lot size
Not set TMC 13.04.088

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The site is in a critical area or its buffer
  2. None of these is true:
    • The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
    • The X District property is across a non-designated Pedestrian Street from UR-1, UR-2 or UR-3 District property
  3. All of these are true:
    • The X District property is across a non-designated Pedestrian Street from UR-1, UR-2 or UR-3 District property
    None of these is true:
    • The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
  4. The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
  5. The lot abuts a designated pedestrian street (TMC 13.06.010D)
  6. None of these is true:
    • The lot abuts a designated pedestrian street (TMC 13.06.010D)
  7. None of these is true:
    • The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
  8. All of these are true:
    • Building height is at most 25
    • Building stories is at most 6
  9. All of these are true:
    • Building height is more than 25
    • Building stories is at most 6
  10. All of these are true:
    • Building stories is more than 6
    None of these is true:
    • Another building on the same site, adjacent to this one, also exceeds six stories
  11. All of these are true:
    • Building stories is more than 6
    • Another building on the same site, adjacent to this one, also exceeds six stories