C-1 · Commercial 1 (C1) zone
Tenino, WA · TMC 106.40.010 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Attached Single-Family Unit | — | ||||
| Group Home | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot width | 20 ft TMC 106.40.010(D)(1)(a) | |
| Minimum lot depth | 24 ft TMC 106.40.010(D)(1)(b) | |
| Minimum frontage |
|
|
| Maximum density |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft TMC 106.40.010(B)(1) | |
| Side setback | 0 ft TMC 106.40.010(B)(1) | |
| Street side setback | 0 ft TMC 106.40.010(B)(1); 108.30.040(B)-(C) | |
| Rear setback | 0 ft TMC 106.40.010(B)(1) | |
| Maximum height | 35 ft TMC 106.40.010(B)(6); 108.30.040(N)(1) | |
| Minimum stories | 2 stories TMC 106.40.010(F)(1) | |
| Maximum impervious surface | 100% TMC 106.40.010(B)(2) | |
| Minimum parking | 1.5 spaces per unit TMC 106.40.010(C)(2); 108.50.020(A) | 0.5 spaces per bed TMC 106.40.010(C)(2); 108.50.020(A)
for Group Home (group living)2 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision TMC 114.60.010; 100.40.070 | A | up to 4 TMC 114.10.040 | — | Minimum lot size Not set TMC 106.40.010(D)(1) Minimum lot width 20 ft TMC 106.40.010(D)(1)(a) Minimum lot depth 24 ft TMC 106.40.010(D)(1)(b) Minimum frontage
|
| Subdivision TMC 114.40.020; 114.40.030; 100.40.110 | H | 5 or more TMC 114.10.040 | — | Minimum lot size Not set TMC 106.40.010(D)(1) Minimum lot width 20 ft TMC 106.40.010(D)(1)(a) Minimum lot depth 24 ft TMC 106.40.010(D)(1)(b) Minimum frontage
|
| Residential condominium binding site plan TMC 114.90.010; 114.90.050; 114.90.060Only for: Attached Single-Family Unit | A | Maximum lots Not set TMC 114.90.040 |
Maximum units Not set TMC 114.90.040(A)(1) |
Minimum lot size Not set TMC 114.90 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The building also has nonresidential units, so each dwelling unit is connected by common walls to at least two other dwelling or nonresidential units
- The housing is part of a mixed-use development
- The dwelling units are not located on the ground floor
- All of these are true:
- The housing is part of a mixed-use development
- The dwelling units are not located on the ground floor
- The lot is a pipestem or flag lot
- None of these is true:
- The lot is a pipestem or flag lot
- Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is individual_water_and_septic
- Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is public_water_and_individual_septic
- Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is public_water_and_sewer