C-3 · Commercial 3 (C3) zone
Tenino, WA · TMC 106.40.030 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Attached Single-Family Unit | HomeA ADU— | HomeA ADU— | — | ||
| Group Home | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot width | 20 ft TMC 106.40.030(D)(1)(a) | |
| Minimum lot depth | 55 ft TMC 106.40.030(D)(1)(b) | |
| Maximum density |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | 5 ft TMC 106.40.030(B)(1)
for Group Home (group living) | |
| Street side setback | 5 ft TMC 106.40.030(B)(1); 108.30.040(B)-(C) | |
| Rear setback | 10 ft TMC 106.40.030(B)(1) | |
| Maximum height | 35 ft TMC 106.40.030(B)(6); 108.30.040(N)(1) | |
| Maximum impervious surface | 90% TMC 106.40.030(B)(2) | |
| Minimum parking | 1.5 spaces per unit TMC 106.40.030(C)(2); 108.50.020(A) | 0.5 spaces per bed TMC 106.40.030(C)(2); 108.50.020(A)
for Group Home (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision TMC 114.60.010; 100.40.070 | A | up to 4 TMC 114.10.040 | — | Minimum lot size Not set TMC 106.40.030(D)(1) Minimum lot width 20 ft TMC 106.40.030(D)(1)(a) Minimum lot depth 55 ft TMC 106.40.030(D)(1)(b) Minimum frontage Not set TMC 106.40.030(D)(1); 108.30.040(E) |
| Subdivision TMC 114.40.020; 114.40.030; 100.40.110 | H | 5 or more TMC 114.10.040 | — | Minimum lot size Not set TMC 106.40.030(D)(1) Minimum lot width 20 ft TMC 106.40.030(D)(1)(a) Minimum lot depth 55 ft TMC 106.40.030(D)(1)(b) Minimum frontage Not set TMC 106.40.030(D)(1); 108.30.040(E) |
| Residential condominium binding site plan TMC 114.90.010; 114.90.050; 114.90.060Only for: Attached Single-Family Unit | A | Maximum lots Not set TMC 114.90.040 |
Maximum units Not set TMC 114.90.040(A)(1) |
Minimum lot size Not set TMC 114.90 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The building also has nonresidential units, so each dwelling unit is connected by common walls to at least two other dwelling or nonresidential units
- Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is individual_water_and_septic
- Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is public_water_and_individual_septic
- Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is public_water_and_sewer
- None of these is true:
- A principal building on an adjacent lot stands within the required front yard, and that lot did not get its reduced setback through a discretionary land use approval
- A principal building on an adjacent lot stands within the required front yard, and that lot did not get its reduced setback through a discretionary land use approval
- A row of townhouses or other attached dwelling units is built on different lots as part of the same development
- None of these is true:
- A row of townhouses or other attached dwelling units is built on different lots as part of the same development