MGSA · McAllister Springs Geologically Sensitive Area Residential District
Thurston County, WA · TCC 21.10 · Official code
By right: 1 unit · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family | Home✓ ADU✓ | — | — | — | — |
| Manufactured home | — | — | — | — | |
| Mobile home | — | — | — | — | |
| Duplex | — | — | — | — | |
| Townhouse | — | — | |||
| Triplex (three family unit) | — | — | — | — | |
| Condominiums | — | — | — | — | |
| Planned residential development | — | — | — | HomeH ADU— | — |
| Mobile or manufactured home park | — | — | — | HomeH ADU— | — |
| Housing for people with functional disabilities | — | — | — | — | Home✓ ADU— |
| Nursing homes, convalescent care facilities | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set TCC 21.61.050(A) | 4 units TCC 21.61.050(A)
for Townhouse (4+ units)4 |
| Minimum units | Not set TCC 21.61.050(A) | 5 units TCC 21.61.050(A)
for Townhouse (4+ units)4 |
| Minimum lot size | Not set TCC 21.10.050 | for Single-family (1 unit); Manufactured home (1 unit)1; Housing for people with functional disabilities (group living) 1,600 × main dwelling units on the lot sq ft TCC 21.61.040(C)
for Townhouse (2, 3, 4+ units)4 No limit TCC 21.60.100
for Planned residential development (4+ units) 4,000 × main dwelling units on the lot sq ft TCC 21.63.120(A)
for Mobile or manufactured home park (4+ units) |
| Minimum lot width | Not set TCC 21.10.050 | for Single-family (1 unit); Manufactured home (1 unit)1; Housing for people with functional disabilities (group living) 40 ft TCC 21.63.070(B)
20 ft TCC 21.61.040(C)
for Townhouse (2, 3, 4+ units)4 No limit TCC 21.60.050(A)
for Planned residential development (4+ units) |
| Minimum lot depth | Not set TCC 21.10.050 | No limit TCC 21.60.050(A)
for Planned residential development (4+ units) 80 ft TCC 21.63.120(C)
for Mobile or manufactured home park (4+ units) |
| Minimum frontage | Not set TCC 21.10.050 | No limit TCC 21.60.050(A)
for Planned residential development (4+ units) |
| Minimum density |
|
No limit TCC 21.03.055
Not set TCC 21.10.050
for Nursing homes, convalescent care facilities (group living) |
| Maximum density |
|
Not set TCC 21.10.050
for Nursing homes, convalescent care facilities (group living) |
| Minimum development size | Not set TCC 21.10.050 | 87,120 sq ft TCC 21.60.080
for Planned residential development (4+ units) 130,680 sq ft TCC 21.63.030(B); 21.63.110
for Mobile or manufactured home park (4+ units) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft TCC 21.61.040(F)
for Townhouse (2, 3, 4+ units)4 Lots intended for attached single-family development or condominiums shall be served by sewer and reviewed and approved through a subdivision, townhouse, or PRD process where the concept is identified and reviewed and approved subject to design requirements of Chapter 21.70. TCC 21.10.050(B)
for Condominiums (4+ units)4 20 ft TCC 21.60.110(A)
for Planned residential development (4+ units) | |
| Side setback | 5 ft TCC 21.63.070(D)(1) | for Single-family (1 unit); Manufactured home (1 unit)1; Housing for people with functional disabilities (group living); Nursing homes, convalescent care facilities (group living) Lots intended for attached single-family development or condominiums shall be served by sewer and reviewed and approved through a subdivision, townhouse, or PRD process where the concept is identified and reviewed and approved subject to design requirements of Chapter 21.70. TCC 21.10.050(B)
for Condominiums (4+ units)4 20 ft TCC 21.60.110(A)
for Planned residential development (4+ units) |
| Total side setbacks | Not set TCC 21.10.050 | for Single-family (1 unit); Manufactured home (1 unit)1; Housing for people with functional disabilities (group living); Nursing homes, convalescent care facilities (group living) |
| Street side setback | Not set TCC 21.10.050 | 10 ft TCC 21.10.050(A)(3)(c)
for Single-family (1 unit); Manufactured home (1 unit)1; Housing for people with functional disabilities (group living); Nursing homes, convalescent care facilities (group living) 20 ft TCC 21.60.110(A)
for Planned residential development (4+ units) |
| Rear setback | 15 ft TCC 21.10.050(A)(5); 21.10.050(D)(7) | Lots intended for attached single-family development or condominiums shall be served by sewer and reviewed and approved through a subdivision, townhouse, or PRD process where the concept is identified and reviewed and approved subject to design requirements of Chapter 21.70. TCC 21.10.050(B)
for Condominiums (4+ units)4 20 ft TCC 21.60.110(A)
for Planned residential development (4+ units) |
| Building separation | Not set TCC 21.10.050 | 10 ft TCC 21.61.040(J)
|
| Maximum height | 35 ft TCC 21.10.050(C)(3)(i) | No limit TCC 21.60.050(A)
for Planned residential development (4+ units) |
| Maximum lot coverage | 60% TCC 21.10.050(C)(1) | |
| Maximum impervious surface | 75% TCC 21.10.050(C)(2) | No limit TCC 21.60.050(A)
for Planned residential development (4+ units) 50% TCC 21.63.120(E); 21.63.150(A)
for Mobile or manufactured home park (4+ units) |
| Minimum parking | 2 spaces per unit TCC 21.10.060; 21.72.030(C); Table 21T-13 | 1.5 spaces per unit TCC 21.10.060; 21.72.030(C); Table 21T-13
Off-street parking shall be provided in a PRD in the same ratios for types of buildings and uses as required for the underlying zoning district, and as described in Chapter 21.72 of this title. TCC 21.60.120
for Planned residential development (4+ units) The parking requirements for any use not listed herein shall be those of the listed use most similar to the unlisted use, as determined by the approval authority. TCC 21.10.060; 21.72.030(A)
for Housing for people with functional disabilities (group living) 0.5 spaces per bed TCC 21.72.030(B); Table 21T-13
for Nursing homes, convalescent care facilities (group living) |
| Maximum lot size | Not set TCC 21.10.050 | 871,200 sq ft TCC 21.63.030(B); 21.63.110
for Mobile or manufactured home park (4+ units) |
| Minimum open space | Not set TCC 21.10.050 | 30% TCC 21.60.140(A)(1)
for Planned residential development (4+ units) 10% TCC 21.63.140
for Mobile or manufactured home park (4+ units) |
| Maximum units per building | Not set TCC 21.10.050 | 6 units TCC 21.61.020
for Townhouse (2, 3, 4+ units)4 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not read TCC 21.06.055 | |
| Minimum lot size | Not read TCC 21.06.055 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | 15 ft TCC 21.10.050(A)(5); 21.10.050(D)(7) | |
| Maximum height | 35 ft TCC 21.10.050(C)(3)(i) | |
| Maximum stories | Not read TCC 21.06.055 | |
| Minimum parking | 1 space per unit TCC 21.10.060; 21.72.030(C); Table 21T-13 | |
| Maximum unit size | Not read TCC 21.06.055 | |
| Attached to the main house | Not read TCC 21.06.055 | |
| Owner lives on site | Not read TCC 21.06.055 |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision TCC 18.32.235(A); 18.32.010 | A | up to 4 TCC 18.08.280; 18.32.010 |
Minimum density
|
|
| Subdivision TCC 18.12.090; 21.81.040 | H | 5 or more TCC 18.08.310 |
Minimum density
|
|
| Short subdivision TCC 21.61.050(A); 21.81.040Only for: Townhouse | A | up to 4 TCC 18.08.280; 18.32.010 |
Minimum density
|
Minimum lot size 1,600 sq ft TCC 21.61.040(C) Minimum lot width 20 ft TCC 21.61.040(C) Maximum units per lot 1 unit TCC 21.61.020; 21.61.050(B) |
| Subdivision TCC 21.61.050(A); 21.81.040; 18.12.090Only for: Townhouse | H | 5 or more TCC 18.08.310 |
Minimum density
|
Minimum lot size 1,600 sq ft TCC 21.61.040(C) Minimum lot width 20 ft TCC 21.61.040(C) Maximum units per lot 1 unit TCC 21.61.020; 21.61.050(B) |
| Mobile or manufactured home subdivision TCC 21.63.030(A); 21.63.050(B); 21.81.040(C)Only for: Manufactured home, Mobile home | H | — |
Minimum parent area 217,800 sq ft TCC 21.63.060 Maximum parent area 1,742,400 sq ft TCC 21.63.060 Minimum density
|
Minimum lot size 4,500 sq ft TCC 21.63.070(A) Minimum lot width 40 ft TCC 21.63.070(B) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Not all of these are true:
- The lot is in a preliminary plat submitted after September 1, 1996
- None of these is true:
- The lot is in an approved mobile or manufactured home subdivision
- The lot is in an approved mobile or manufactured home subdivision
- All of these are true:
- The two- or three-family units are within the up to five percent of total lots allowed for them
- The lot is served by public sewer
- The lot is served by public sewer
- All of these are true:
- The lot is served by public sewer
- Alleys are utilized for access to the lot
- Not all of these are true:
- The lot is served by public sewer
- Alleys are utilized for access to the lot
- All of these are true:
- The lot is served by public sewer
- Alleys are utilized for access to the lot
- None of these is true:
- The lot is served by public sewer
- None of these is true:
- The property contains wetlands or wetland buffers as defined in the Thurston County Critical Areas Ordinance TCC Title 24
- The property contains wetlands or wetland buffers as defined in the Thurston County Critical Areas Ordinance TCC Title 24
- All of these are true:
- The lot is served by public sewer
- The property contains wetlands or wetland buffers as defined in the Thurston County Critical Areas Ordinance TCC Title 24
- None of these is true:
- The lot is served by public sewer
- The property contains wetlands or wetland buffers as defined in the Thurston County Critical Areas Ordinance TCC Title 24
- All of these are true:
- A ten-foot planter strip is provided between the street and the sidewalk
- Alleys are utilized for access to the lot
- Not all of these are true:
- A ten-foot planter strip is provided between the street and the sidewalk
- Alleys are utilized for access to the lot
- The property fronts on a major street
- All of these are true:
- A ten-foot planter strip is provided between the street and the sidewalk
- Alleys are utilized for access to the lot
- The property fronts on a major street
- All of these are true:
- Not all of these are true:
- A ten-foot planter strip is provided between the street and the sidewalk
- Alleys are utilized for access to the lot
- The property fronts on a major street
- Not all of these are true:
- All of these are true:
- Any of these is true:
- The site is part of a subdivision
- The site is part of a planned residential development (PRD)
- A zero lot line concept has been approved for the subdivision or PRD the site is part of
- The site has undergone (or will undergo) design review as part of the approval process
- The site utilizes alleys with the majority of units using alleys for access
- Any of these is true:
- Not all of these are true:
- Any of these is true:
- The site is part of a subdivision
- The site is part of a planned residential development (PRD)
- A zero lot line concept has been approved for the subdivision or PRD the site is part of
- The site has undergone (or will undergo) design review as part of the approval process
- The site utilizes alleys with the majority of units using alleys for access
- Any of these is true: