Sign in

R5-12/1 · Residential—Five to Twelve Dwelling Units per Acre (R 5-12/1)

Thurston County, WA · TCC 20.15 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, Single-Family
Home✓ ADU✓
————
Supportive Housing, Permanent
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Dwelling, Duplex (two-family dwelling)—
Home✓ ADU✓
———
Mobile or manufactured home park—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Cottage housing—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Dwelling, Triplex——
Home✓ ADU✓
——
Planned residential development———
HomeH ADU✓
—
Supportive Housing, Transitional————
Home✓ ADU✓
Residential care facility————
Home✓ ADU✓
Nursing or convalescent home————
HomeH ADU✓

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set TCC 20.15.060
4 units TCC 20.31.020(1)
for Mobile or manufactured home park (4+ units)
Minimum unitsNot set TCC 20.15.060
2 units TCC 20.31.020(1)
for Mobile or manufactured home park (4+ units); Cottage housing (4+ units)
5 units TCC 20.31.020(2); 20.54.070(21.6)
for Mobile or manufactured home park (4+ units)
Minimum lot sizeNot set TCC 20.15.060
  • 5,000 sq ft1 TCC 20.15.060(1)(a)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.2 TCC 20.56.020(2)
  • 13,000 sq ft3 TCC 20.15.060(1)(a)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.4 TCC 20.56.020(2)
  • 3,000 sq ft5 TCC 20.15.060(1)(b)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.6 TCC 20.56.020(2)
for Dwelling, Single-Family (1 unit)
  • 5,000 sq ft7 TCC 20.15.060(1)(a)
  • 13,000 sq ft8 TCC 20.15.060(1)(a)
  • 3,000 sq ft9 TCC 20.15.060(1)(b)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.10 TCC 20.56.020(2)
for Supportive Housing, Permanent (1 unit); Supportive Housing, Transitional (group living)
  • 7,000 sq ft7 TCC 20.15.060(1)(a)
  • 26,000 sq ft8 TCC 20.15.060(1)(a)
  • 3,000 sq ft9 TCC 20.15.060(1)(b)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.10 TCC 20.56.020(2)
for Dwelling, Duplex (two-family dwelling) (2 units)
  • 2,400 × main dwelling units on the lot sq ft11 TCC 20.31.030(11)(a)
  • 3,600 × main dwelling units on the lot sq ft12 TCC 20.31.030(11)(b)
  • 4,800 × main dwelling units on the lot sq ft13 TCC 20.31.030(11)(c)
for Mobile or manufactured home park (2, 3, 4+ units)
  • Not set14 TCC 20.15.060(1)
  • 3,000 sq ft9 TCC 20.15.060(1)(b)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.10 TCC 20.56.020(2)
for Dwelling, Triplex (3 units)
No limit TCC 20.30.050(3)
for Planned residential development (4+ units)
  • the largest of 5,000, 12,500 sq ft15 TCC 20.15.060(1)(a); 20.54.070(34)(d)
  • the largest of 13,000, 12,500 sq ft16 TCC 20.15.060(1)(a); 20.54.070(34)(d)
  • the largest of 3,000, 12,500 sq ft17 TCC 20.15.060(1)(b); 20.54.070(34)(d)
for Residential care facility (group living)
  • the largest of 5,000, 12,500, 12,000 + (1,000 × (residents − 10)) sq ft15 TCC 20.15.060(1)(a); 20.54.070(34)(d)
  • the largest of 13,000, 12,500, 12,000 + (1,000 × (residents − 10)) sq ft16 TCC 20.15.060(1)(a); 20.54.070(34)(d)
  • the largest of 3,000, 12,500, 12,000 + (1,000 × (residents − 10)) sq ft17 TCC 20.15.060(1)(b); 20.54.070(34)(d)
for Residential care facility (group living)18
20,000 sq ft TCC 20.15.060(1)(c); 20.54.040(2)
for Nursing or convalescent home (group living)
Minimum lot width
  • 50 ft19 TCC 20.15.060(2)(a)(i)-(ii); 20.15.060(2)(a)(iv)-(v)
  • 35 ft20 TCC 20.15.060(2)(a)(i)-(ii); 20.15.060(2)(a)(iv)-(v)
  • 20 ft21 TCC 20.15.060(2)(a)(i)-(ii); 20.15.060(2)(a)(iv)-(v)
  • 50 ft22 TCC 20.15.060(2)(a)(i)-(ii); 20.15.060(2)(a)(iv)-(v)
  • 30 ft23 TCC 20.15.060(2)(b)(i)-(ii)
  • 20 ft24 TCC 20.15.060(2)(b)(i)-(ii)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.10 TCC 20.56.020(2)
  • 50 ft25 TCC 20.15.060(2)(a)(i)-(ii); 20.15.060(2)(a)(iv)-(v)
  • 35 ft26 TCC 20.15.060(2)(a)(i)-(ii); 20.15.060(2)(a)(iv)-(v)
  • 20 ft27 TCC 20.15.060(2)(a)(i)-(ii); 20.15.060(2)(a)(iv)-(v)
  • 50 ft28 TCC 20.15.060(2)(a)(i)-(ii); 20.15.060(2)(a)(iv)-(v)
  • 30 ft29 TCC 20.15.060(2)(b)(i)-(ii)
  • 20 ft30 TCC 20.15.060(2)(b)(i)-(ii)
for Mobile or manufactured home park (2, 3, 4+ units); Residential care facility (group living); Residential care facility (group living)18; Nursing or convalescent home (group living)
No limit TCC 20.30.040(1)
for Planned residential development (4+ units)
Minimum density
  • 5 units per acre31 TCC 20.15.050(1)
  • A conversion plan must be submitted ... which demonstrates that the reserve tract can be subsequently subdivided to create sufficient lots to achieve the minimum densities32 TCC 20.15.070(1)-(2)
Maximum density12 units per acre TCC 20.15.050(2)
  • 12 units per acre33 TCC 20.15.050(2)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.34 TCC 20.56.020(2)
for Dwelling, Single-Family (1 unit)
  • 12 units per acre35 TCC 20.38.030(B); 20.15.050(2)
  • 12 × 1.5 units per acre36 TCC 20.38.030(B)(1); 20.15.050(2)
for Cottage housing (2, 3, 4+ units)
  • 12 units per acre37 TCC 20.15.050(2); 20.30.050(3)
  • 14.4 units per acre, a fraction of 0.5 or more rounds up38 TCC 20.30.050(4); 20.30.060(6)
for Planned residential development (4+ units)
Minimum development sizeNot set TCC 20.15.060
43,560 sq ft TCC 20.30.050(2)(a)(i)
for Planned residential development (4+ units)
Maximum residentsNot set TCC 20.15.060
5 persons TCC 20.54.070(34)(a)
for Residential care facility (group living)
20 persons TCC 20.54.070(34)(c)
for Residential care facility (group living)18

3. Building standards

StandardValueExceptions
Front setback
  • 25 ft39 TCC 20.15.060(5)(a); 20.07.030(1)
  • 20 ft40 TCC 20.15.060(5)(a); 20.07.030(1)
  • the largest of 60 − (width of the street right-of-way in front of the lot ÷ 2), 20 ft39 TCC 20.31.030(4)(a)(iii)-(iv)
  • the largest of 50 − (width of the street right-of-way in front of the lot ÷ 2), 20 ft40 TCC 20.31.030(4)(a)(iii)-(iv)
for Mobile or manufactured home park (2, 3, 4+ units)
10 ft TCC 20.38.030(J)(1)
for Cottage housing (2, 3, 4+ units)
Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (4+ units)
Side setback5 ft TCC 20.15.060(5)(a); 20.07.030(1)
10 ft TCC 20.31.030(4)(a)(ii)
for Mobile or manufactured home park (2, 3, 4+ units)
Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (4+ units)
Street side setback10 ft TCC 20.15.060(5)(a); 20.07.030(1)
  • the largest of 60 − (width of the street right-of-way in front of the lot ÷ 2), 20 ft39 TCC 20.31.030(4)(a)(iii)-(iv)
  • the largest of 50 − (width of the street right-of-way in front of the lot ÷ 2), 20 ft40 TCC 20.31.030(4)(a)(iii)-(iv)
for Mobile or manufactured home park (2, 3, 4+ units)
Not set TCC 20.38.030(J)
for Cottage housing (2, 3, 4+ units)
Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (4+ units)
Rear setback5 ft TCC 20.15.060(5)(a); 20.07.030(1)
10 ft TCC 20.31.030(4)(a)(ii)
for Mobile or manufactured home park (2, 3, 4+ units)
Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (4+ units)
Building separationNot set TCC 20.15.060
10 ft TCC 20.31.030(4)(b)
for Mobile or manufactured home park (2, 3, 4+ units); Cottage housing (2, 3, 4+ units); Planned residential development (4+ units)
Maximum height35 ft TCC 20.15.060(4)
25 ft TCC 20.38.030(I)(1)
for Cottage housing (2, 3, 4+ units)
The specific setback, lot size, height limits and other dimensional requirements are waived, and the regulations for PRD's shall be those indicated in Section 20.30.060. TCC 20.30.040(1)
for Planned residential development (4+ units)
Maximum impervious surfacethe smallest of 60, (20,000 ÷ lot area) × 100% TCC 20.15.060(6)
Minimum parking1 space per unit TCC 20.44.030(1)(a)(i)
(2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 4) spaces TCC 20.31.030(5)(a)-(b)
for Mobile or manufactured home park (2, 3, 4+ units)
1.5 spaces per unit TCC 20.38.030(L)(1)
for Cottage housing (2, 3, 4+ units)
  • 1 space per unit41 TCC 20.44.030(1)(a)(i)-(ii)
  • 0 spaces per unit42 TCC 20.44.030(1)(a)(iii)
for Supportive Housing, Permanent (4+ units); Planned residential development (4+ units)
1 + employees on the largest shift spaces TCC 20.54.070(34)(e); 20.44.030(1)(a)(i)
for Residential care facility (group living); Residential care facility (group living)18
0.2 spaces per bed TCC 20.44.030(1)(b)(v)
for Nursing or convalescent home (group living)
Maximum unit sizeNot set TCC 20.15.060
1,200 sq ft TCC 20.38.030(D)
for Cottage housing (2, 3, 4+ units)
Maximum building footprintNot set TCC 20.15.060
1,000 sq ft TCC 20.38.030(D)
for Cottage housing (2, 3, 4+ units)
Minimum open spaceNot set TCC 20.15.060
  • 10%43 TCC 20.31.030(6)(a)-(b)
  • Not set44 TCC 20.31.030(6)
for Mobile or manufactured home park (2, 3, 4+ units)
20% TCC 20.38.030(G)
for Cottage housing (2, 3, 4+ units)
30% TCC 20.30.060(1)
for Planned residential development (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units TCC 20.34.040(1)
Minimum lot size0 sq ft TCC 20.34.040(2)(a)

Building

StandardValueExceptions
Front setback
  • 25 ft39 TCC 20.34.040(3); TCC 20.15.060(5)(a); 20.07.030(1)
  • 20 ft40 TCC 20.34.040(3); TCC 20.15.060(5)(a); 20.07.030(1)
Side setback5 ft TCC 20.34.040(3); TCC 20.15.060(5)(a); 20.07.030(1)
Rear setback5 ft TCC 20.34.040(3); TCC 20.15.060(5)(a); 20.07.030(1)
Maximum height35 ft TCC 20.34.040(3); TCC 20.15.060(4)
Minimum parking1 space per unit TCC 20.34.050(6)
Maximum unit size1,000 sq ft TCC 20.34.040(4)(a)
Attached to the main houseNot required TCC 20.34.040(1)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision TCC 18.32.010; 18.32.140(D) A up to 4 TCC 18.08.280; 18.32.010 12 units per acre TCC 20.15.050(2)
Minimum density
5 units per acre TCC 20.15.050(1)
Minimum lot size
  • 5,000 sq ft45 TCC 20.15.060(1)(a)
  • 13,000 sq ft46 TCC 20.15.060(1)(a)
Minimum lot width
50 ft TCC 20.15.060(2)(a)(i)
Subdivision TCC 18.12.090; 20.60.020 Table 2 H 5 or more TCC 18.08.310 12 units per acre TCC 20.15.050(2)
Minimum density
5 units per acre TCC 20.15.050(1)
Minimum lot size
  • 5,000 sq ft45 TCC 20.15.060(1)(a)
  • 13,000 sq ft46 TCC 20.15.060(1)(a)
Minimum lot width
50 ft TCC 20.15.060(2)(a)(i)
Cluster subdivision TCC 20.03.040(20); 18.32.010; 18.32.140(D) A up to 4 TCC 18.08.280; 18.32.010 12 units per acre TCC 20.15.050(2)
Minimum density
5 units per acre TCC 20.15.050(1)
Minimum lot size
3,000 sq ft TCC 20.15.060(1)(b)
Cluster subdivision TCC 20.03.040(20); 18.12.090; 20.60.020 Table 2 H 5 or more TCC 18.08.310 12 units per acre TCC 20.15.050(2)
Minimum density
5 units per acre TCC 20.15.050(1)
Minimum lot size
3,000 sq ft TCC 20.15.060(1)(b)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The lot is served by public sewer
    • Not all of these are true:
      • The lot is a legal lot under TCC 18.04.045
      • Lot area is less than 5,000 sf
    None of these is true:
    • The lot is (or will be) a lot in a cluster subdivision
  2. All of these are true:
    • The lot is served by public sewer
    • The lot is a legal lot under TCC 18.04.045
    • Lot area is less than 5,000 sf
    None of these is true:
    • The lot is (or will be) a lot in a cluster subdivision
  3. All of these are true:
    • Not all of these are true:
      • The lot is a legal lot under TCC 18.04.045
      • Lot area is less than 13,000 sf
    None of these is true:
    • The lot is (or will be) a lot in a cluster subdivision
    • The lot is served by public sewer
  4. All of these are true:
    • The lot is a legal lot under TCC 18.04.045
    • Lot area is less than 13,000 sf
    None of these is true:
    • The lot is (or will be) a lot in a cluster subdivision
    • The lot is served by public sewer
  5. All of these are true:
    • The lot is (or will be) a lot in a cluster subdivision
    • Not all of these are true:
      • The lot is a legal lot under TCC 18.04.045
      • Lot area is less than 3,000 sf
  6. All of these are true:
    • The lot is (or will be) a lot in a cluster subdivision
    • The lot is a legal lot under TCC 18.04.045
    • Lot area is less than 3,000 sf
  7. All of these are true:
    • The lot is served by public sewer
    None of these is true:
    • The lot is a legal lot under TCC 18.04.045
    • The lot is (or will be) a lot in a cluster subdivision
  8. None of these is true:
    • The lot is a legal lot under TCC 18.04.045
    • The lot is (or will be) a lot in a cluster subdivision
    • The lot is served by public sewer
  9. All of these are true:
    • The lot is (or will be) a lot in a cluster subdivision
    None of these is true:
    • The lot is a legal lot under TCC 18.04.045
  10. The lot is a legal lot under TCC 18.04.045
  11. Width class of the mobile/manufactured homes placed in the park is single_wide
  12. Width class of the mobile/manufactured homes placed in the park is double_wide
  13. Width class of the mobile/manufactured homes placed in the park is triple_wide
  14. None of these is true:
    • The lot is a legal lot under TCC 18.04.045
    • The lot is (or will be) a lot in a cluster subdivision
  15. All of these are true:
    • The lot is served by public sewer
    None of these is true:
    • The lot is (or will be) a lot in a cluster subdivision
  16. None of these is true:
    • The lot is (or will be) a lot in a cluster subdivision
    • The lot is served by public sewer
  17. The lot is (or will be) a lot in a cluster subdivision
  18. Residents is more than 5
  19. All of these are true:
    • Corner lot
    None of these is true:
    • The lot is a legal lot under TCC 18.04.045
    • The lot is (or will be) a lot in a cluster subdivision
  20. All of these are true:
    • Lot fronting a cul-de-sac
    None of these is true:
    • The lot is a legal lot under TCC 18.04.045
    • The lot is (or will be) a lot in a cluster subdivision
    • Corner lot
  21. All of these are true:
    • Flag lot
    None of these is true:
    • The lot is a legal lot under TCC 18.04.045
    • The lot is (or will be) a lot in a cluster subdivision
    • Corner lot
    • Lot fronting a cul-de-sac
  22. None of these is true:
    • The lot is a legal lot under TCC 18.04.045
    • The lot is (or will be) a lot in a cluster subdivision
    • Corner lot
    • Lot fronting a cul-de-sac
    • Flag lot
  23. All of these are true:
    • The lot is (or will be) a lot in a cluster subdivision
    • Corner lot
    None of these is true:
    • The lot is a legal lot under TCC 18.04.045
  24. All of these are true:
    • The lot is (or will be) a lot in a cluster subdivision
    None of these is true:
    • The lot is a legal lot under TCC 18.04.045
    • Corner lot
  25. All of these are true:
    • Corner lot
    None of these is true:
    • The lot is (or will be) a lot in a cluster subdivision
  26. All of these are true:
    • Lot fronting a cul-de-sac
    None of these is true:
    • The lot is (or will be) a lot in a cluster subdivision
    • Corner lot
  27. All of these are true:
    • Flag lot
    None of these is true:
    • The lot is (or will be) a lot in a cluster subdivision
    • Corner lot
    • Lot fronting a cul-de-sac
  28. None of these is true:
    • The lot is (or will be) a lot in a cluster subdivision
    • Corner lot
    • Lot fronting a cul-de-sac
    • Flag lot
  29. All of these are true:
    • The lot is (or will be) a lot in a cluster subdivision
    • Corner lot
  30. All of these are true:
    • The lot is (or will be) a lot in a cluster subdivision
    None of these is true:
    • Corner lot
  31. None of these is true:
    • Lot area is more than 43,560 sf
    • None of these is true:
      • The lot is served by public sewer
  32. Any of these is true:
    • Lot area is more than 43,560 sf
    • None of these is true:
      • The lot is served by public sewer
  33. Not all of these are true:
    • The lot is a legal lot under TCC 18.04.045
    • Lot area is less than 3,630 sf
  34. All of these are true:
    • The lot is a legal lot under TCC 18.04.045
    • Lot area is less than 3,630 sf
  35. None of these is true:
    • All cottages are built under a green building certificate program (LEED, Passive House, Four Star Built Green)
  36. All cottages are built under a green building certificate program (LEED, Passive House, Four Star Built Green)
  37. None of these is true:
    • The PRD provides the open space amenities that qualify for the density bonus
  38. The PRD provides the open space amenities that qualify for the density bonus
  39. The front yard faces an arterial, state highway or railroad right-of-way (not a collector, local or private road)
  40. None of these is true:
    • The front yard faces an arterial, state highway or railroad right-of-way (not a collector, local or private road)
  41. Main dwelling units on the lot is at most 4
  42. Main dwelling units on the lot is more than 4
  43. Lot area is at least 435,600 sf
  44. Lot area is less than 435,600 sf
  45. The lot is served by public sewer
  46. None of these is true:
    • The lot is served by public sewer