RR1/5 · Rural Residential—One Dwelling Unit per Five Acres (RR 1/5)
Thurston County, WA · TCC 20.09 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, Single-Family | — | ||||
| Supportive Housing, Permanent | — | ||||
| Dwelling, Duplex (two-family dwelling) | — | — | — | ||
| Mobile or manufactured home park | — | — | |||
| Planned residential development | — | — | |||
| Supportive Housing, Transitional | — | — | — | — | |
| Residential care facility | — | — | — | — | |
| Nursing or convalescent home | — | — | — | — | |
| Secure community transition facility | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 4 units TCC 20.09.020(2); 20.34.040(2)(a) | Not set TCC 20.09.040
for Supportive Housing, Permanent (4+ units); Mobile or manufactured home park (4+ units); Planned residential development (4+ units) |
| Minimum units | Not set TCC 20.09.020(2) | 2 units TCC 20.31.020(1)
for Mobile or manufactured home park (4+ units) 5 units TCC 20.31.020(2); 20.54.070(21.6)
for Mobile or manufactured home park (4+ units) |
| Minimum lot size |
|
for Supportive Housing, Permanent (1 unit); Supportive Housing, Transitional (group living)
for Dwelling, Duplex (two-family dwelling) (2 units); Dwelling, Duplex (two-family dwelling) (4+ units)4 Not set TCC 20.09.040
for Supportive Housing, Permanent (2, 3, 4+ units) for Mobile or manufactured home park (2, 3, 4+ units) No limit TCC 20.30.050(3)
for Planned residential development (2, 3, 4+ units) the largest of 174,240, 12,500 sq ft TCC 20.09.040(1)(a); 20.54.070(34)(d)
for Residential care facility (group living) the largest of 174,240, 12,500, 12,000 + (1,000 × (residents − 10)) sq ft TCC 20.09.040(1)(a); 20.54.070(34)(d)
for Residential care facility (group living)14 217,800 sq ft TCC 20.09.040(1)(b); 20.54.040(2)
for Nursing or convalescent home (group living); Secure community transition facility (group living)6 |
| Minimum lot width | Not set TCC 20.09.040 | No limit TCC 20.30.040(1)
for Planned residential development (2, 3, 4+ units) |
| Maximum density | 1 unit per 217,800 sq ft, on the net lot area TCC 20.09.050(1); 20.09.050(2)(a)-(c) |
1 unit per 217,800 sq ft TCC 20.30.050(3)-(4); 20.09.050(1); 20.09.050(2)(d)
for Planned residential development (2, 3, 4+ units) |
| Minimum development size | Not set TCC 20.09.040 | 871,200 sq ft TCC 20.30.050(2)(b)(i)
for Planned residential development (2, 3, 4+ units) |
| Maximum residents | Not set TCC 20.09.040 | 5 persons TCC 20.54.070(34)(a)
for Residential care facility (group living) 20 persons TCC 20.54.070(34)(c)
for Residential care facility (group living)14 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | for Mobile or manufactured home park (2, 3, 4+ units) Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (2, 3, 4+ units) | |
| Side setback | 5 ft TCC 20.09.040(3); 20.07.030(1) | 10 ft TCC 20.31.030(4)(a)(ii)
for Mobile or manufactured home park (2, 3, 4+ units) Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (2, 3, 4+ units) |
| Street side setback | 10 ft TCC 20.09.040(3); 20.07.030(1) | for Mobile or manufactured home park (2, 3, 4+ units) Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (2, 3, 4+ units) |
| Rear setback | 5 ft TCC 20.09.040(3); 20.07.030(1) | 10 ft TCC 20.31.030(4)(a)(ii)
for Mobile or manufactured home park (2, 3, 4+ units) Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (2, 3, 4+ units) |
| Building separation | Not set TCC 20.09.040 | 10 ft TCC 20.31.030(4)(b)
for Mobile or manufactured home park (2, 3, 4+ units); Planned residential development (2, 3, 4+ units) |
| Maximum height | 35 ft TCC 20.09.040(2) | The specific setback, lot size, height limits and other dimensional requirements are waived, and the regulations for PRD's shall be those indicated in Section 20.30.060. TCC 20.30.040(1)
for Planned residential development (2, 3, 4+ units) |
| Maximum impervious surface | ||
| Minimum parking | 1 space per unit TCC 20.44.030(1)(a)(i) | (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 4) spaces TCC 20.31.030(5)(a)-(b)
for Mobile or manufactured home park (2, 3, 4+ units) for Supportive Housing, Permanent (4+ units); Planned residential development (4+ units) 1 + employees on the largest shift spaces TCC 20.54.070(34)(e); 20.44.030(1)(a)(i)
0.2 spaces per bed TCC 20.44.030(1)(b)(v)
for Nursing or convalescent home (group living) The off-street parking requirements for uses not specifically mentioned in this section shall be the same as the use most similar from the standpoint of parking needs TCC 20.44.030(3)
for Secure community transition facility (group living)6 |
| Minimum open space | Not set TCC 20.09.040 | 30% TCC 20.30.060(1)
for Planned residential development (2, 3, 4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units TCC 20.34.040(1) | |
| Minimum lot size | 0 sq ft TCC 20.34.020(2)(a) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 5 ft TCC 20.34.020(3); TCC 20.09.040(3); 20.07.030(1) | |
| Rear setback | 5 ft TCC 20.34.020(3); TCC 20.09.040(3); 20.07.030(1) | |
| Maximum height | 35 ft TCC 20.34.020(3); TCC 20.09.040(2) | |
| Minimum parking | 1 space per unit TCC 20.34.050(6) | |
| Maximum unit size | 1,000 sq ft TCC 20.34.040(4)(a) | 0.5 × floor area of the main house sq ft TCC 20.34.020(4)(a)
for Dwelling, Single-Family (1 unit)1 No limit TCC 20.34.020(4)(b)
for Dwelling, Single-Family (1 unit)2 |
| Attached to the main house | Not required TCC 20.03.040(37.1)(b); 20.34.020(4)(b) | Required TCC 20.03.040(37.1)(a)
for Dwelling, Single-Family (1 unit)1 |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision TCC 18.32.010; 18.32.140(D) | A | up to 4 TCC 18.08.280; 18.32.010 | 1 unit per 217,800 sq ft, on the net lot area TCC 20.09.050(1); 20.09.050(2)(a)-(c) | Minimum lot size 174,240 sq ft TCC 20.09.040(1)(a) |
| Subdivision TCC 18.12.090; 20.60.020 Table 2 | H | 5 or more TCC 18.08.310 | 1 unit per 217,800 sq ft, on the net lot area TCC 20.09.050(1); 20.09.050(2)(a)-(c) | Minimum lot size 174,240 sq ft TCC 20.09.040(1)(a) |
| Large lot subdivision TCC 18.28.010; 18.28.030(B); 20.60.020 Table 2 | A | 2 or more TCC 18.08.183; 18.28.010 | 1 unit per 217,800 sq ft, on the net lot area TCC 20.09.050(1); 20.09.050(2)(a)-(c) | Minimum lot size 217,800 sq ft TCC 18.08.183 |
| Subdivisions within the Nisqually subarea TCC 20.09.045; 18.32.010; 18.32.140(D) | A27 | up to 4 TCC 18.08.280; 18.32.010 | 0.24 units per acre, on the net lot area TCC 20.09.045(3); 20.09.050(1) Minimum parent area 871,200 sq ft TCC 20.09.045 |
Minimum lot size 21,780 sq ft TCC 20.09.045(4) |
| Subdivisions within the Nisqually subarea TCC 20.09.045; 18.12.090; 20.60.020 Table 2 | H27 | 5 or more TCC 18.08.310 | 0.24 units per acre, on the net lot area TCC 20.09.045(3); 20.09.050(1) Minimum parent area 871,200 sq ft TCC 20.09.045 |
Minimum lot size 21,780 sq ft TCC 20.09.045(4) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is adu_attached
- The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
- All of these are true:
- Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is adu_conversion
- The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
- All of these are true:
- Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is adu_detached
- A detached ADU on the lot is consistent with historical rural density patterns, as calculated by the department
- The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
- The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
- All of these are true:
- The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
- The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
- All of these are true:
- Any of these is true:
- None of these is true:
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a school (public or private) or a school site owned by a school district or private school and planned for school development in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a licensed pre-school in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a licensed child care home or day care center in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a sports field, playground or public park in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a church, synagogue, temple or mosque in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a recreational or community center in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a school bus stop in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a public library in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a publicly dedicated trail in existence when the site is applied for
- Waterbodies, bluffs, freeways or a similar barrier effectively preclude access from the site to the separated uses
- Following a public hearing, the hearing examiner reduces the separation standards of subsection (b) on the applicant's request, because no site is available that meets them
- None of these is true:
- Any of these is true:
- None of these is true:
- The site is within five hundred feet of a residence or a vacant residential lot
- The applicant obtains development rights or easements that preclude the siting of a residence within five hundred feet of the facility
- Waterbodies, bluffs, freeways or a similar barrier effectively preclude access from the site to the separated uses
- Following a public hearing, the hearing examiner reduces the separation standards of subsection (b) on the applicant's request, because no site is available that meets them
- None of these is true:
- Any of these is true:
- No site is available in any district with a higher siting preference (in order: long-term forestry, military reservation, industrial, commercial) than the district of the proposed site
- The proposed site would pose less of a public safety risk than alternative sites
- Any of these is true:
- The proposed site would pose less of a public safety risk than alternative sites
- No site meeting the secure community transition facility requirements is available in other zoning districts
- Any of these is true:
- Not all of these are true:
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 174,240 sf
- All of these are true:
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 174,240 sf
- None of these is true:
- The lot is a legal lot under TCC 18.04.045
- The lot is a legal lot under TCC 18.04.045
- Width class of the mobile/manufactured homes placed in the park is single_wide
- Width class of the mobile/manufactured homes placed in the park is double_wide
- Width class of the mobile/manufactured homes placed in the park is triple_wide
- Residents is more than 5
- Not all of these are true:
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 217,800 sf
- All of these are true:
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 217,800 sf
- Not all of these are true:
- The state requires the county to accommodate additional committed sex offenders
- The hearing examiner authorizes up to a total of six offenders in the secure community transition facility, on a request processed under Chapter 20.54
- All of these are true:
- The state requires the county to accommodate additional committed sex offenders
- The hearing examiner authorizes up to a total of six offenders in the secure community transition facility, on a request processed under Chapter 20.54
- The front yard faces an arterial, state highway or railroad right-of-way (not a collector, local or private road)
- None of these is true:
- The front yard faces an arterial, state highway or railroad right-of-way (not a collector, local or private road)
- Lot area is at least 108,900 sf
- Lot area is less than 108,900 sf
- Main dwelling units on the lot is at most 4
- Main dwelling units on the lot is more than 4
- None of these is true:
- One transferable development right is purchased from the Long-Term Agriculture District under Chapter 20.62
- One transferable development right is purchased from the Long-Term Agriculture District under Chapter 20.62
- All of these are true:
- The parcel is within the Nisqually subarea
- Lot area is at least 871,200 sf