MU-O · Mixed Use – Office
University Place, WA · UPMC 19.20.030(B)(5); 19.25.110; 19.45.100 · Official code
By right: 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Live-work unit | HomeA ADU— | — | — | — | — |
| Multifamily housing | — | — | — | ||
| Single-family attached housing | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Adult family home (6 or fewer) | — | — | — | — | Home✓ ADU— |
| Level I group home | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
| Assisted living facility | — | — | — | — | Home✓ ADU— |
| Nursing home | — | — | — | — | Home✓ ADU— |
| Level II group homes | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 4,000 sq ft UPMC 19.45.100 | |
| Maximum density | 65 units per acre, on the net lot area UPMC 19.45.100; 19.45.030(A); 19.45.030(C) | |
| Maximum residents | Not set UPMC 19.25.040 | 6 persons UPMC 19.25.040(A)
for Adult family home (6 or fewer) (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | All buildings shall be oriented and built at the edge of the sidewalk except: a. Where a plaza or courtyard lies between the building and sidewalk, in which case the building shall be built to the edge of the plaza or courtyard. b. At significant corners a minimum setback of 20 feet is required between the building and sidewalk, to accommodate a plaza or courtyard. UPMC 19.50.040(A)(2) | |
| Maximum front setback | All buildings shall be oriented and built at the edge of the sidewalk except: a. Where a plaza or courtyard lies between the building and sidewalk, in which case the building shall be built to the edge of the plaza or courtyard. b. At significant corners a minimum setback of 20 feet is required between the building and sidewalk, to accommodate a plaza or courtyard. UPMC 19.50.040(A)(2) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | 45 ft UPMC 19.45.100 | |
| Minimum height | 25 ft UPMC 19.50.050(A)(3) | |
| Maximum lot coverage | 45% UPMC 19.45.100 | |
| Minimum parking | In the case of a use not specifically mentioned in this chapter, the requirements for off-street parking facilities shall be determined by the Director. UPMC 19.60.070 | for Multifamily housing (3, 4+ units)1 2 spaces per unit UPMC 19.60.050
for Single-family attached housing (3, 4+ units) employees on the largest shift + 2 spaces UPMC 19.60.050
for Adult family home (6 or fewer) (group living) 0.5 spaces per bed UPMC 19.60.050
for Level I group home (group living); Assisted living facility (group living); Level II group homes (group living) 0.25 spaces per bed UPMC 19.60.050
for Nursing home (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision UPMC 21.35.060(A) | A | up to 9 UPMC 21.10.010 | — | Minimum lot size 4,000 sq ft UPMC 19.45.100 |
| Subdivision UPMC 21.20.050(A) | H | 10 or more UPMC 21.10.010 | — | Minimum lot size 4,000 sq ft UPMC 19.45.100 |
| Unit lot subdivision UPMC 21.75.020 | A | up to 9 UPMC 21.75.020 | Minimum units 2 units UPMC 21.75.010(B) |
Minimum lot size Not set UPMC 21.75.030 |
| Unit lot subdivision UPMC 21.75.020; 21.20.050(A) | H | 10 or more UPMC 21.75.020 | Minimum units 2 units UPMC 21.75.010(B) |
Minimum lot size Not set UPMC 21.75.030 |
| Residential condominium binding site plan UPMC 21.45.040; 21.40.050(A) | A | Maximum lots Not set UPMC 21.45 |
— | Minimum lot size Not set UPMC 21.45 |
| Binding site plan UPMC 21.40.050(A) | A | Maximum lots Not set UPMC 21.40 |
— | Minimum lot size 4,000 sq ft UPMC 19.45.100 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- New multifamily is built in conjunction with other permitted commercial uses
- None of these is true:
- The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
- All of these are true:
- The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
- The subject parcel is in a transition properties overlay
- All of these are true:
- The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
- The abutting R1 or R2 parcels are part of the project site
- The subject parcel is in a transition properties overlay
- All of these are true:
- The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
- The subject parcel is in a transition properties overlay
- The abutting R1 or R2 parcels are part of the project site
- The side yard is the common lot line of attached units
- None of these is true:
- The side yard is the common lot line of attached units
- Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)
- All of these are true:
- Bedrooms in one unit is less than 2
- Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)
- All of these are true:
- Bedrooms in one unit is at least 2
- Bedrooms in one unit is at most 2
- Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)
- All of these are true:
- Bedrooms in one unit is at least 3
- Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)