MHP · Manufactured Home Development District (MH)
Vancouver, WA · VMC 20.410.120 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Manufactured Home | — | — | — | — | |
| Manufactured Home, Modular | — | — | — | — | |
| Single-Family Residential Building Type (SFB) | — | — | — | — | |
| Townhouse/Rowhouse Building Type (TRB) | — | — | |||
| Stacked Multi-Plex Building Type (SMB) | — | — | |||
| Flex-Plex Building Type (FPB) | — | — | |||
| Cottage Court Building Type (CCB) | — | — | |||
| Temporary shelter/housing (i.e., safe stays, transitional housing) | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set VMC 20.420.080(A) | 6 units VMC 20.420.100(A)
for Flex-Plex Building Type (FPB) (4+ units)2 |
| Minimum lot size | No limit VMC 20.420.070(C)(1)(a)(i) | |
| Minimum density | No limit VMC 20.410.120(C)(1) | |
| Maximum density | No limit VMC 20.410.120(C)(2) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 5 ft VMC 20.420.070(D)(1)(f)(i) | |
| Maximum front setback | 20 ft VMC 20.420.070(D)(1)(f)(i) | Not set VMC 20.450.085(C)
25 ft VMC 20.420.110(D)(1)(f)(i)
for Cottage Court Building Type (CCB) (2, 3, 4+ units)2 |
| Side setback | 5 ft VMC 20.450.085(C)(1) | |
| Street side setback | 5 ft VMC 20.420.070(D)(1)(g)(i) | |
| Rear setback | 5 ft VMC 20.450.085(C)(1)
| |
| Maximum height | ||
| Minimum height | No limit VMC 20.410.120(D)(1) | |
| Maximum impervious surface | 85% VMC 20.420.080(C)(1)(e)(i) | Not set VMC 20.450.085(C)
65% VMC 20.420.070(C)(1)(e)(i)
No limit VMC 20.420.110(C)(1)(e)(i)
for Cottage Court Building Type (CCB) (2, 3, 4+ units)2 |
| Minimum parking | 0 spaces per unit VMC 20.450.045(F)(5) | |
| Maximum unit size | Not set VMC 20.450.085(C) | 1,600 sq ft VMC 20.450.080(A)(1)
for Cottage Court Building Type (CCB) (2, 3, 4+ units)2 |
| Maximum lot size | 40,000 sq ft VMC 20.420.100(C)(1)(a)(ii) | Not set VMC 20.450.085(C)
5,000 sq ft VMC 20.420.070(C)(1)(a)(ii)
No limit VMC 20.420.090(C)(1)(a)(ii)
for Stacked Multi-Plex Building Type (SMB) (2, 3, 4+ units)2 |
| Minimum open space | 10% VMC 20.420.080(C)(1)(d)(i) | Not set VMC 20.450.085(C)(5)
20% VMC 20.420.070(C)(1)(d)(i)
for Single-Family Residential Building Type (SFB) (1 unit)2 No limit VMC 20.420.110(C)(1)(d)(i)
for Cottage Court Building Type (CCB) (2, 3, 4+ units)2 |
| Maximum units per building | Not set VMC 20.420.080(A) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not read RCW 36.70A.681; named in VMC 20.420.080(A) | |
| Minimum lot size | No limit VMC 20.420.100(C)(1)(a)(i) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 5 ft VMC 20.420.100(D)(1)(f)(i) | |
| Side setback | 5 ft VMC 20.420.100(D)(1)(h)(i) | |
| Rear setback | ||
| Maximum height | ||
| Minimum parking | 0 spaces per unit VMC 20.450.045(F)(5) | |
| Maximum unit size | 1,000 sq ft VMC 20.150.040A | |
| Attached to the main house | Not required VMC 20.150.040A | Required VMC 20.450.080(A)(6)(c)
for Cottage Court Building Type (CCB) (2, 3, 4+ units)2 |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision VMC 20.320.020(A)(1) | A | up to 9 VMC 20.320.015(A) | — | Minimum frontage 16 ft VMC 20.320.070(A)(1)(g) |
| Subdivision VMC 20.320.020(A)(1) | H | 10 or more VMC 20.320.015(B) | — | Minimum frontage 16 ft VMC 20.320.070(A)(1)(g) |
| Unit Lot Subdivision VMC 20.320.100(C); 20.320.020(A)(1) | A11 | up to 9 VMC 20.320.100(B)(2) | — | Minimum lot size Each unit lot’s area and width for purposes of subdivision may be as small as the footprint of the building situated upon it, subject to the requirements of the building and fire codes. VMC 20.320.100(D)(6) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Lot is in a manufactured home development established before the effective date of VMC 20.450.085
- All units, across all structures, are maintained as permanently affordable at or below 60 percent of area median income (AMI)
- Property is owned or controlled by a religious organization
- None of these is true:
- Property is owned or controlled by a religious organization
- None of these is true:
- The rear lot line abuts an alley
- The rear lot line abuts an alley
- None of these is true:
- Lot is within the Station Areas Overlay (Figure 20.530.020-1), within one-quarter mile of an existing or planned bus rapid or light rail transit
- Lot is within the Station Areas Overlay (Figure 20.530.020-1), within one-quarter mile of an existing or planned bus rapid or light rail transit
- Main dwelling units on the lot is at most 6
- Main dwelling units on the lot is more than 6
- The division is for residential development only, with no commercial or other nonresidential use