Sign in

MHP · Manufactured Home Development District (MH)

Vancouver, WA · VMC 20.410.120 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Manufactured Home
Home✓1 ADU—
————
Manufactured Home, Modular
Home✓1 ADU—
————
Single-Family Residential Building Type (SFB)
Home✓2 ADU✓2
————
Townhouse/Rowhouse Building Type (TRB)—
Home✓2 ADU✓2
Home✓2 ADU✓2
Home✓2 ADU✓2
—
Stacked Multi-Plex Building Type (SMB)—
Home✓2 ADU✓2
Home✓2 ADU✓2
Home✓2 ADU✓2
—
Flex-Plex Building Type (FPB)—
Home✓2 ADU✓2
Home✓2 ADU✓2
Home✓2 ADU✓2
—
Cottage Court Building Type (CCB)—
Home✓2 ADU✓2
Home✓2 ADU✓2
Home✓2 ADU✓2
—
Temporary shelter/housing (i.e., safe stays, transitional housing)————
Home✓3 H4 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set VMC 20.420.080(A)
6 units VMC 20.420.100(A)
for Flex-Plex Building Type (FPB) (4+ units)2
Minimum lot sizeNo limit VMC 20.420.070(C)(1)(a)(i)
Not set VMC 20.450.085(C)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)4; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)3
Minimum densityNo limit VMC 20.410.120(C)(1)
Not set VMC 20.450.085(B)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1
Maximum densityNo limit VMC 20.410.120(C)(2)
Not set VMC 20.450.085(B)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1

3. Building standards

StandardValueExceptions
Front setback5 ft VMC 20.420.070(D)(1)(f)(i)
10 ft VMC 20.450.085(C)(1)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1
Not set VMC 20.410.120
for Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)4; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)3
Maximum front setback20 ft VMC 20.420.070(D)(1)(f)(i)
Not set VMC 20.450.085(C)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)4; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)3
25 ft VMC 20.420.110(D)(1)(f)(i)
for Cottage Court Building Type (CCB) (2, 3, 4+ units)2
Side setback5 ft VMC 20.450.085(C)(1)
Not set VMC 20.410.120
for Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)4; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)3
Street side setback5 ft VMC 20.420.070(D)(1)(g)(i)
10 ft VMC 20.450.085(C)(1)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1
Not set VMC 20.410.120
for Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)4; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)3
Rear setback
  • 5 ft5 VMC 20.420.080(D)(1)(i)(i)
  • 0 ft6 VMC 20.420.080(D)(1)(i)(ii)
5 ft VMC 20.450.085(C)(1)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1; Single-Family Residential Building Type (SFB) (1 unit)2
Not set VMC 20.410.120
for Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)4; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)3
Maximum height
  • 45 ft7 VMC 20.410.120(D)(2)
  • No limit8 VMC 20.530.040(A); VMC 20.420.070(G)(3)
Not set VMC 20.450.085(B)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1
Minimum heightNo limit VMC 20.410.120(D)(1)
Not set VMC 20.450.085(B)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1
Maximum impervious surface85% VMC 20.420.080(C)(1)(e)(i)
Not set VMC 20.450.085(C)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)4; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)3
65% VMC 20.420.070(C)(1)(e)(i)
for Single-Family Residential Building Type (SFB) (1 unit)2; Flex-Plex Building Type (FPB) (2, 3 units)2
No limit VMC 20.420.110(C)(1)(e)(i)
for Cottage Court Building Type (CCB) (2, 3, 4+ units)2
  • 75%9 VMC 20.420.100(C)(1)(e)(ii)
  • 85%10 VMC 20.420.100(C)(1)(e)(iii)
for Flex-Plex Building Type (FPB) (4+ units)2
Minimum parking0 spaces per unit VMC 20.450.045(F)(5)
0 spaces per resident VMC 20.450.045(F)(5)
for Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)4; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)3
Maximum unit sizeNot set VMC 20.450.085(C)
1,600 sq ft VMC 20.450.080(A)(1)
for Cottage Court Building Type (CCB) (2, 3, 4+ units)2
Maximum lot size40,000 sq ft VMC 20.420.100(C)(1)(a)(ii)
Not set VMC 20.450.085(C)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)4; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)3
5,000 sq ft VMC 20.420.070(C)(1)(a)(ii)
for Single-Family Residential Building Type (SFB) (1 unit)2; Townhouse/Rowhouse Building Type (TRB) (2, 3, 4+ units)2
No limit VMC 20.420.090(C)(1)(a)(ii)
for Stacked Multi-Plex Building Type (SMB) (2, 3, 4+ units)2
Minimum open space10% VMC 20.420.080(C)(1)(d)(i)
Not set VMC 20.450.085(C)(5)
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)4; Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)3
20% VMC 20.420.070(C)(1)(d)(i)
for Single-Family Residential Building Type (SFB) (1 unit)2
No limit VMC 20.420.110(C)(1)(d)(i)
for Cottage Court Building Type (CCB) (2, 3, 4+ units)2
Maximum units per buildingNot set VMC 20.420.080(A)
1 unit VMC 20.150.040D
for Manufactured Home (1 unit)1; Manufactured Home, Modular (1 unit)1; Single-Family Residential Building Type (SFB) (1 unit)2

4. ADU standards

Lot

StandardValueExceptions
Maximum unitsNot read RCW 36.70A.681; named in VMC 20.420.080(A)
2 units VMC 20.420.100(A)
for Single-Family Residential Building Type (SFB) (1 unit)2; Flex-Plex Building Type (FPB) (2, 3, 4+ units)2
Minimum lot sizeNo limit VMC 20.420.100(C)(1)(a)(i)

Building

StandardValueExceptions
Front setback5 ft VMC 20.420.100(D)(1)(f)(i)
Side setback5 ft VMC 20.420.100(D)(1)(h)(i)
Rear setback
  • 5 ft5 VMC 20.420.100(D)(1)(i)(i)
  • 0 ft6 VMC 20.420.100(D)(1)(i)(ii)
Maximum height
  • 45 ft7 VMC 20.410.120(D)(2)
  • No limit8 VMC 20.530.040(A); VMC 20.420.100(G)(3)
Minimum parking0 spaces per unit VMC 20.450.045(F)(5)
Maximum unit size1,000 sq ft VMC 20.150.040A
Attached to the main houseNot required VMC 20.150.040A
Required VMC 20.450.080(A)(6)(c)
for Cottage Court Building Type (CCB) (2, 3, 4+ units)2

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision VMC 20.320.020(A)(1) A up to 9 VMC 20.320.015(A) —
Minimum frontage
16 ft VMC 20.320.070(A)(1)(g)
Subdivision VMC 20.320.020(A)(1) H 10 or more VMC 20.320.015(B) —
Minimum frontage
16 ft VMC 20.320.070(A)(1)(g)
Unit Lot Subdivision VMC 20.320.100(C); 20.320.020(A)(1) A11 up to 9 VMC 20.320.100(B)(2) —
Minimum lot size
Each unit lot’s area and width for purposes of subdivision may be as small as the footprint of the building situated upon it, subject to the requirements of the building and fire codes. VMC 20.320.100(D)(6)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Lot is in a manufactured home development established before the effective date of VMC 20.450.085
  2. All units, across all structures, are maintained as permanently affordable at or below 60 percent of area median income (AMI)
  3. Property is owned or controlled by a religious organization
  4. None of these is true:
    • Property is owned or controlled by a religious organization
  5. None of these is true:
    • The rear lot line abuts an alley
  6. The rear lot line abuts an alley
  7. None of these is true:
    • Lot is within the Station Areas Overlay (Figure 20.530.020-1), within one-quarter mile of an existing or planned bus rapid or light rail transit
  8. Lot is within the Station Areas Overlay (Figure 20.530.020-1), within one-quarter mile of an existing or planned bus rapid or light rail transit
  9. Main dwelling units on the lot is at most 6
  10. Main dwelling units on the lot is more than 6
  11. The division is for residential development only, with no commercial or other nonresidential use