Sign in

CC · CC community commercial

Washougal, WA · WMC 18.32 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Mixed commercial and residential use, including professional offices
Home✓1 ADU—
Home✓1 ADU—
———
High density multifamily residential within a mixed use development——
Home✓1 ADU—
Home✓1 ADU—
—
Rooming and boarding houses————
Home✓ ADU—
Residential and congregate care facilities————
Home✓ ADU—
Sanitarium, convalescent and rest homes————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size5,000 sq ft WMC 18.32.030 Table 18.32-2; WMC 18.32.030 Table 18.32-2 note (A)
Minimum frontage30 ft WMC 18.32.030 Table 18.32-2
Minimum densityNot set WMC 18.32.020 Table 18.32-1 row A.4; WMC 18.32.030 Table 18.32-2
10 units per acre WMC 18.32.020 Table 18.32-1 row A.3
for High density multifamily residential within a mixed use development (3, 4+ units)1
Maximum density16 units per acre WMC 18.32.030 Table 18.32-2
  • 16 units per acre2 WMC 18.32.020 Table 18.32-1 row A.3; WMC 18.32.030 Table 18.32-2
  • 30 units per acre3 WMC 18.32.020 Table 18.32-1 row A.3
for High density multifamily residential within a mixed use development (3, 4+ units)1

3. Building standards

StandardValueExceptions
Front setback0 ft WMC 18.32.030 Table 18.32-2
Maximum front setbackCommercial buildings shall be set as close as possible to the sidewalk. WMC 18.32.040(2)(c)(i)
Side setback0 ft WMC 18.32.030 Table 18.32-2
Rear setback0 ft WMC 18.32.030 Table 18.32-2
Maximum height75 ft WMC 18.32.030 Table 18.32-2
Maximum lot coverageNo limit WMC 18.32.030 Table 18.32-2
Minimum parking2 spaces per unit WMC 18.52.040 Table 18.52-1
1.5 spaces per unit WMC 18.52.040 Table 18.52-1
for High density multifamily residential within a mixed use development (3, 4+ units)1
2 + sleeping units in the project spaces WMC 18.52.040 Table 18.52-1
for Rooming and boarding houses (group living)
(beds in the project ÷ 3) + employees on the largest shift spaces WMC 18.52.040 Table 18.52-1
for Residential and congregate care facilities (group living); Sanitarium, convalescent and rest homes (group living)
Maximum units per buildingNot set WMC 18.32.020 Table 18.32-1 row A.4
  • 6 units4 WMC 18.32.020 Table 18.32-1 row A.3; WMC 18.46.200
  • Not set5 WMC 18.32.020 Table 18.32-1 row A.3
for High density multifamily residential within a mixed use development (3, 4+ units)1

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision WMC 17.12.020(1); Table 18.94-1 A up to 9 WMC 17.44.040(11) —
Minimum lot size
5,000 sq ft WMC 17.44.150(1); WMC 18.32.030 Table 18.32-2; WMC 18.32.030 Table 18.32-2 note (A)
Minimum frontage
30 ft WMC 17.44.150(1); WMC 18.32.030 Table 18.32-2
Subdivision WMC 17.12.030(1); Table 18.94-1 H 10 or more WMC 17.44.040(12) —
Minimum lot size
5,000 sq ft WMC 17.44.150(1); WMC 18.32.030 Table 18.32-2; WMC 18.32.030 Table 18.32-2 note (A)
Minimum frontage
30 ft WMC 17.44.150(1); WMC 18.32.030 Table 18.32-2
Binding site plan WMC 17.48.020(1); Table 18.94-1 A —
  • 16 units per acre2 WMC 18.32.020 Table 18.32-1 row A.3; WMC 18.32.030 Table 18.32-2
  • 30 units per acre3 WMC 18.32.020 Table 18.32-1 row A.3
Minimum lot size
Not set WMC 17.48.010(2); 17.48.030

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The housing is part of a mixed use development with commercial use
  2. None of these is true:
    • The building has retail or commercial on the first floor and residential above
  3. The building has retail or commercial on the first floor and residential above
  4. The multifamily units are built as townhouses, each on its own lot
  5. None of these is true:
    • The multifamily units are built as townhouses, each on its own lot