TC-WV · TC-WV town center west village
Washougal, WA · WMC 18.35 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached Single-Family | Home✓ ADU✓ | — | — | — | — |
| Manufactured Homes | Home✓ ADU✓ | — | — | — | — |
| Duplexes | — | Home✓ ADU— | — | — | — |
| Multiple-family | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Townhouses | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Cottage Housing | — | — | — | — | |
| Adult Family Homes | — | — | — | — | Home✓ ADU— |
| Rooming and boarding houses | — | — | — | — | Home✓ ADU— |
| Institutionalized Residential Living Facilities | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set WMC 18.35.040 | 12 units WMC 18.45.030
for Cottage Housing (4+ units)1 |
| Minimum units | Not set WMC 18.35.040 | 4 units WMC 18.45.030
for Cottage Housing (4+ units)1 |
| Minimum lot size | Not set WMC 18.35.090(2)(d) | 2,000 sq ft WMC 18.46.200
for Townhouses (3, 4+ units) No limit WMC 18.45.030
for Cottage Housing (4+ units)1 |
| Minimum lot width | Not set WMC 18.35.040 | 18 ft WMC 18.46.200
for Townhouses (3, 4+ units) No limit WMC 18.45.030
for Cottage Housing (4+ units)1 |
| Minimum lot depth | Not set WMC 18.35.040 | No limit WMC 18.45.030
for Cottage Housing (4+ units)1 |
| Minimum frontage | Not set WMC 18.35.040 | 18 ft WMC 18.46.200
for Townhouses (3, 4+ units) No limit WMC 18.45.030
for Cottage Housing (4+ units)1 |
| Maximum residents | Not set WMC 18.35.040 | 6 persons WMC 18.06.060
for Adult Family Homes (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | Not set WMC 18.35.040 | 10 ft WMC 18.35.090(2)(d); 18.14.030 Table 18.14-2
|
| Maximum front setback | ||
| Side setback | Not set WMC 18.35.040 | 5 ft WMC 18.35.090(2)(d); 18.14.030 Table 18.14-2
|
| Street side setback | Not set WMC 18.35.040 | 10 ft WMC 18.35.090(2)(d); 18.14.030 Table 18.14-2
|
| Rear setback | Not set WMC 18.35.040 | 10 ft WMC 18.35.090(2)(d); 18.14.030 Table 18.14-2
for Detached Single-Family (1 unit); Manufactured Homes (1 unit) 5 ft WMC 18.45.070(5)(a)
for Cottage Housing (4+ units)1 |
| Building separation | Not set WMC 18.35.040 | 10 ft WMC 18.45.070(6)(a)
for Cottage Housing (4+ units)1 |
| Maximum height | 18 ft WMC 18.45.070(1)(a)
for Cottage Housing (4+ units)1 | |
| Maximum stories | Not set WMC 18.35.040 | Structures in cottage housing developments shall be designed to be single-story or single-story plus a loft. WMC 18.45.070(1)
for Cottage Housing (4+ units)1 |
| Maximum lot coverage | Not set WMC 18.35.040 | No limit WMC 18.46.200
for Townhouses (3, 4+ units) |
| Maximum impervious surface | Not set WMC 18.35.040 | 60% WMC 18.45.110(3)
for Cottage Housing (4+ units)1 |
| Maximum floor area ratio | 0.6 WMC 18.35.040(1)(a) | |
| Minimum parking | for Cottage Housing (4+ units)1 Parking requirements for uses not listed shall be determined by a study of parking demand for that use. WMC 18.35.040(3)(a)(i)
for Adult Family Homes (group living); Rooming and boarding houses (group living); Institutionalized Residential Living Facilities (group living) | |
| Maximum unit size | Not set WMC 18.35.040 | 1,200 sq ft WMC 18.45.040
for Cottage Housing (4+ units)1 |
| Maximum lot size | Not set WMC 18.35.040 | |
| Minimum open space | Not set WMC 18.35.040 | 20% WMC 18.45.080(2)
for Cottage Housing (4+ units)1 |
| Maximum units per building | Not set WMC 18.35.040 | 6 units WMC 18.46.200
for Townhouses (3, 4+ units) 1 unit WMC 18.06.335(1)-(2)
for Cottage Housing (4+ units)1 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit WMC 18.46.020(1)(b) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft WMC 18.46.020(1)(f); WMC 18.35.090(2)(d); 18.14.030 Table 18.14-2 | |
| Side setback | 5 ft WMC 18.46.020(1)(f); WMC 18.35.090(2)(d); 18.14.030 Table 18.14-2 | |
| Rear setback | 10 ft WMC 18.46.020(1)(f); WMC 18.35.090(2)(d); 18.14.030 Table 18.14-2 | |
| Maximum height | 35 ft WMC 18.46.020(1)(c); WMC 18.35.040(2) | |
| Minimum parking | 1 space per unit WMC 18.46.020(1)(h) | |
| Maximum unit size | the largest of 300, the smallest of 0.4 × floor area of the main house, 800 sq ft WMC 18.46.020(1)(d)-(e) | |
| Attached to the main house | Not required WMC 18.46.020(1)(a) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision WMC 17.12.020(1); Table 18.94-1Only for: Detached Single-Family, Manufactured Homes | A | up to 9 WMC 17.44.040(11) | — | Minimum lot size 5,000 sq ft WMC 18.35.090(2)(d); 18.14.030 Table 18.14-2 |
| Short subdivision WMC 17.12.020(1); Table 18.94-1Only for: Townhouses | A | up to 9 WMC 17.44.040(11) | — | Minimum lot size 2,000 sq ft WMC 18.46.200 Minimum lot width 18 ft WMC 18.46.200 Minimum frontage 18 ft WMC 18.46.200 |
| Short subdivision WMC 17.12.020(1); Table 18.94-1Only for: Duplexes, Multiple-family, Cottage Housing, Adult Family Homes, Rooming and boarding houses, Institutionalized Residential Living Facilities | A | up to 9 WMC 17.44.040(11) | — | Minimum lot size Not set WMC 18.35.040; 18.35.090(2)(c) |
| Subdivision WMC 17.12.030(1); Table 18.94-1Only for: Detached Single-Family, Manufactured Homes | H | 10 or more WMC 17.44.040(12) | — | Minimum lot size 5,000 sq ft WMC 18.35.090(2)(d); 18.14.030 Table 18.14-2 |
| Subdivision WMC 17.12.030(1); Table 18.94-1Only for: Townhouses | H | 10 or more WMC 17.44.040(12) | — | Minimum lot size 2,000 sq ft WMC 18.46.200 Minimum lot width 18 ft WMC 18.46.200 Minimum frontage 18 ft WMC 18.46.200 |
| Subdivision WMC 17.12.030(1); Table 18.94-1Only for: Duplexes, Multiple-family, Cottage Housing, Adult Family Homes, Rooming and boarding houses, Institutionalized Residential Living Facilities | H | 10 or more WMC 17.44.040(12) | — | Minimum lot size Not set WMC 18.35.040; 18.35.090(2)(c) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Lot area is at most 108,900 sf
- The building is along a pedestrian-oriented street
- None of these is true:
- The building is along a pedestrian-oriented street
- None of these is true:
- The top of the building is designed as a nonhabitable architectural element
- The top of the building is designed as a nonhabitable architectural element
- Bedrooms in one unit is 0
- Bedrooms in one unit is 1
- Bedrooms in one unit is at least 2
- Floor area of one unit is at most 800
- Floor area of one unit is more than 800
- None of these is true:
- The cottage housing development is condominiumized (one commonly owned property)
- The cottage housing development is condominiumized (one commonly owned property)