Sign in

C · C commercial district

Wilkeson, WA · WMC 17.03.040 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwellings
Home✓ ADU—
————
Duplexes—
Home✓ ADU—
———
Multifamily dwellings, including apartments and townhouses——
Home✓ ADU—
Home✓ ADU—
—
Transitional housing facilities————
Home✓ ADU—
Rest homes————
Home✓ ADU—
Retirement homes————
HomeH ADU—
Convalescent homes————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size2,500 sq ft WMC 17.03.040(E)(1)
8,500 + (2,500 × (the largest of main dwelling units on the lot − 2, 0)) sq ft WMC 17.03.040(A)(3)(e)(ii); WMC 17.03.030(G)(2)(a)
for Multifamily dwellings, including apartments and townhouses (3, 4+ units)
Minimum lot width30 ft WMC 17.03.040(E)(3)
Minimum frontage30 ft WMC 16.05.070
Maximum densityNot set WMC 17.03.040
16 units per acre WMC 17.03.040(A)(3)(e)(ii); WMC 17.03.030(G)(2)(c)
for Multifamily dwellings, including apartments and townhouses (3, 4+ units)
Maximum residentsNot set WMC 17.03.040
20 persons WMC 17.03.040(A)(3)(d)
for Transitional housing facilities (group living)

3. Building standards

StandardValueExceptions
Front setback0 ft WMC 17.03.040(E)(4)(a)
Side setback0 ft WMC 17.03.040(E)(4)(b)
Street side setback10 ft WMC 17.07.130
Rear setback0 ft WMC 17.03.040(E)(4)(c)
Maximum height40 ft WMC 17.03.040(E)(5)
Maximum stories3 stories WMC 17.03.040(E)(5)
Maximum lot coverage100% WMC 17.03.040(E)(2)
Minimum parking0 spaces per bed WMC 17.04.060
0 spaces per unit WMC 17.04.060
for Single-family dwellings (1 unit); Duplexes (2 units)
1 space per unit WMC 17.04.060
for Multifamily dwellings, including apartments and townhouses (3, 4+ units)
0 spaces per resident WMC 17.04.060
for Transitional housing facilities (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short plats WMC 16.03.030 A
Maximum lots
Not set WMC 16.03
—
Minimum lot size
2,500 sq ft WMC 17.03.040(E)(1)
Minimum lot width
30 ft WMC 17.03.040(E)(3)
Minimum frontage
30 ft WMC 16.05.070
Preliminary and final plats WMC 16.02.050; 16.02.060 H
Minimum lots
Not set WMC 16.02
—
Minimum lot size
2,500 sq ft WMC 17.03.040(E)(1)
Minimum lot width
30 ft WMC 17.03.040(E)(3)
Minimum frontage
30 ft WMC 16.05.070
Large lot plats WMC 16.04.030 A
Maximum lots
Not set WMC 16.04
—
Minimum lot size
2,500 sq ft WMC 17.03.040(E)(1)
Minimum lot width
30 ft WMC 17.03.040(E)(3)
Minimum frontage
30 ft WMC 16.05.070
Planned unit development, PUD WMC 17.03.060(A); 17.03.060(E)(5) H — The Planning Commission may recommend a dwelling unit density not more than twenty (20) percent greater than that permitted by the underlying zone upon findings and conclusions that the amenities or design features which promote the purposes of this subsection, as follows, are provided: WMC 17.03.060(D)
Minimum parent area
Minimum site acreage for a PUD is established according to the zoning district in which the PUD is located. WMC 17.03.060(C)(2)
Minimum lot size
No limit WMC 17.03.060(C)(1)
Minimum lot width
Specific development standards such as lot size, street design, etc. shall be provided as outlined in the amended subdivision code. WMC 17.03.060(C)(10)
Binding site plans WMC 16.09.030 H
Maximum lots
Not set WMC 16.09
—
Minimum lot size
2,500 sq ft WMC 17.03.040(E)(1)
Minimum lot width
30 ft WMC 17.03.040(E)(3)
Minimum frontage
30 ft WMC 16.05.070

✓ By right   A Administrative review   H Public hearing   — Not allowed