Sign in

R3 · R-3 residential district, multifamily

Wilkeson, WA · WMC 17.03.030 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwellings
Home✓ ADU—
————
Duplexes—
Home✓ ADU—
———
Multifamily dwellings, including apartments and townhouses——
Home✓ ADU—
Home✓ ADU—
—
Rest homes————
HomeH ADU—
Retirement homes————
HomeH ADU—
Convalescent homes————
HomeH ADU—
Rooming and boarding————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size8,500 sq ft WMC 17.03.030(G)(1); WMC 17.03.020(G)(1)
5,000 sq ft WMC 17.03.030(G)(1); WMC 17.03.020(G)(1)
for Single-family dwellings (1 unit); Rooming and boarding (group living)
8,500 + (2,500 × (the largest of main dwelling units on the lot − 2, 0)) sq ft WMC 17.03.030(A); WMC 17.03.030(G)(2)(a)
for Multifamily dwellings, including apartments and townhouses (3, 4+ units)
Minimum lot width75 ft WMC 17.03.030(G)(1); WMC 17.03.020(G)(2)
Minimum frontage30 ft WMC 17.03.030(G)(1); WMC 17.03.020(G)(2)
Maximum densityNot set WMC 17.03.030
16 units per acre WMC 17.03.030(G)(2)(c)
for Multifamily dwellings, including apartments and townhouses (3, 4+ units)
Maximum residentsNot set WMC 17.03.030
3 persons WMC 17.03.030(E)(2)
for Rooming and boarding (group living)

3. Building standards

StandardValueExceptions
Front setback15 ft WMC 17.03.030(G)(1); 17.03.020(G)(4)(a)
Side setback7 ft WMC 17.03.030(G)(1); 17.03.020(G)(4)(b)
Street side setback15 ft WMC 17.03.030(G)(1); 17.03.020(G)(4)(d); 17.03.020(G)(4)(e)
Rear setback
  • 15 ft1 WMC 17.03.030(G)(1); 17.03.020(G)(4)(c)
  • 7 ft2 WMC 17.03.030(G)(1); 17.03.020(G)(4)(c)
Building separationNot set WMC 17.03.030(G)(1); 17.03.020
the largest of 12, building height ft WMC 17.03.030(G)(2)(f)(ii)
for Multifamily dwellings, including apartments and townhouses (3, 4+ units)
Maximum height40 ft WMC 17.03.030(G)(2)(h)
32 ft WMC 17.03.030(G)(1); 17.03.020(G)(5)
for Single-family dwellings (1 unit); Duplexes (2 units); Rooming and boarding (group living)
Maximum stories3 stories WMC 17.03.030(G)(2)(h)
Not set WMC 17.03.030(G)(1); 17.03.020(G)(5)
for Single-family dwellings (1 unit); Duplexes (2 units); Rooming and boarding (group living)
Maximum lot coverage50% WMC 17.03.030(G)(1); 17.03.020(G)(3)
Minimum parkingOne (1) parking space for each two (2) beds, plus one (1) parking space for each staff doctor, plus one (1) parking space for each three (3) employees. WMC 17.04.040(K)(2)
2 spaces per unit WMC 17.04.040(F)(1)(a)
for Single-family dwellings (1 unit); Duplexes (2 units)
  • 1 space per unit3 WMC 17.04.040(F)(1)(c)
  • 2 spaces per unit4 WMC 17.04.040(F)(1)(c)
  • 1.8 spaces per unit5 WMC 17.04.040(F)(1)(c)
for Multifamily dwellings, including apartments and townhouses (3, 4+ units)
1 + sleeping units in the project + (employees on the largest shift ÷ 4) spaces WMC 17.04.040(F)(2)
for Rooming and boarding (group living)
Minimum open space25% WMC 17.06.060(B)(2)
No limit WMC 17.06.060(A)
for Single-family dwellings (1 unit)
Not set WMC 17.06.060
for Duplexes (2 units)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short plats WMC 16.03.030 A
Maximum lots
Not set WMC 16.03
—
Minimum lot size
5,000 sq ft WMC 17.03.030(G)(1); WMC 17.03.020(G)(1)
Minimum lot width
75 ft WMC 17.03.030(G)(1); WMC 17.03.020(G)(2)
Minimum frontage
30 ft WMC 16.05.070
Preliminary and final plats WMC 16.02.050; 16.02.060 H
Minimum lots
Not set WMC 16.02
—
Minimum lot size
5,000 sq ft WMC 17.03.030(G)(1); WMC 17.03.020(G)(1)
Minimum lot width
75 ft WMC 17.03.030(G)(1); WMC 17.03.020(G)(2)
Minimum frontage
30 ft WMC 16.05.070
Large lot plats WMC 16.04.030 A
Maximum lots
Not set WMC 16.04
—
Minimum lot size
5,000 sq ft WMC 17.03.030(G)(1); WMC 17.03.020(G)(1)
Minimum lot width
75 ft WMC 17.03.030(G)(1); WMC 17.03.020(G)(2)
Minimum frontage
30 ft WMC 16.05.070
Planned unit development, PUD WMC 17.03.060(A); 17.03.060(E)(5) H — The Planning Commission may recommend a dwelling unit density not more than twenty (20) percent greater than that permitted by the underlying zone upon findings and conclusions that the amenities or design features which promote the purposes of this subsection, as follows, are provided: WMC 17.03.060(D)
Minimum parent area
Minimum site acreage for a PUD is established according to the zoning district in which the PUD is located. WMC 17.03.060(C)(2)
Minimum lot size
No limit WMC 17.03.060(C)(1)
Minimum lot width
Specific development standards such as lot size, street design, etc. shall be provided as outlined in the amended subdivision code. WMC 17.03.060(C)(10)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The rear yard abuts an alley or street
  2. None of these is true:
    • The rear yard abuts an alley or street
  3. Floor area of one unit is at most 400
  4. All of these are true:
    • Floor area of one unit is more than 400
    • Main dwelling units on the lot is at most 49
  5. All of these are true:
    • Floor area of one unit is more than 400
    • Main dwelling units on the lot is at least 50