Sign in

R-16 · High-density residential district

Yelm, WA · YMC 18.33 · Official code

By right: 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family residential units
Home✓1 ADU—
————
Duplexes—
Home✓ ADU—
———
Townhouses—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Multifamily dwellings———
Home✓ ADU—
—
Planned residential development———
HomeH ADU—
—
Residential care facilities————
Home✓ ADU—
Convalescent care facilities————
HomeH ADU—
Assisted living facilities————
HomeH ADU—
Congregate care facilities————
HomeH ADU—
Emergency housing————
HomeH ADU—
Emergency shelters————
HomeH ADU—
Permanent supportive housing————
HomeH ADU—
Transitional housing————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum unitsNot set YMC 18.33.020(C)
4 units YMC 18.02.040
for Multifamily dwellings (4+ units)
Minimum lot sizeNo limit YMC 18.33.040(B)
Minimum densityNot set YMC 18.33.040
8 units per acre YMC 18.33.040(A)
for Single-family residential units (1 unit)1; Duplexes (2 units); Townhouses (2, 3, 4+ units); Multifamily dwellings (4+ units); Planned residential development (4+ units)
Maximum densityNot set YMC 18.33.040
16 units per acre YMC 18.33.040(A); 18.30.010(C)
for Single-family residential units (1 unit)1; Duplexes (2 units); Multifamily dwellings (4+ units)
  • 16 units per acre2 YMC 18.33.040(A); 18.30.010(C)
  • 16 × (1 + (25 ÷ 100)) units per acre, a fraction of 0.5 or more rounds up3 YMC 18.33.040(A); 18.64.020(A)(3); 18.64.050(A)(1)(c)
for Townhouses (2, 3, 4+ units); Planned residential development (4+ units)
Minimum development sizeNot set YMC 18.33.040
2 × 43,560 sq ft YMC 18.33.040(J)
for Townhouses (2, 3, 4+ units)
Maximum residentsNot read YMC 18.71
15 persons YMC 18.02.040
for Residential care facilities (group living)
Not set YMC 18.33.040
for Convalescent care facilities (group living); Assisted living facilities (group living); Congregate care facilities (group living)
Maximum bedsNot set YMC 18.33.040
Not read YMC 18.71
for Emergency housing (group living); Emergency shelters (group living); Permanent supportive housing (group living); Transitional housing (group living)
Maximum sleeping unitsNot set YMC 18.33.040
Not read YMC 18.71
for Emergency housing (group living); Emergency shelters (group living); Permanent supportive housing (group living); Transitional housing (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 15 ft4 YMC 18.33.040(C)(1)
  • 25 ft5 YMC 18.33.040(C)(2)
  • 35 ft6 YMC 18.33.040(C)(3)
  • 25 ft4 YMC 18.33.040(C)(1); 18.64.050(A)(3)
  • 25 ft5 YMC 18.33.040(C)(2); 18.64.050(A)(3)
  • 35 ft6 YMC 18.33.040(C)(3)
for Townhouses (2, 3, 4+ units)
Side setback10 ft YMC 18.33.040(D)
Street side setback20 ft YMC 18.33.040(E)
25 ft YMC 18.64.050(A)(3)
for Townhouses (2, 3, 4+ units)
Rear setback25 ft YMC 18.33.040(F)
Building separationNot set YMC 18.33.040
10 ft YMC 18.64.050(A)(6)
for Townhouses (2, 3, 4+ units); Planned residential development (4+ units)
Maximum height45 ft YMC 18.33.040(H)(1)
Maximum stories3 stories YMC 18.33.040(H)(1)
Minimum parking2 spaces per unit YMC 18.54.030(A)
  • 2 spaces per unit7 YMC 18.54.030(A)
  • 1 + (1 ÷ 10) spaces per unit8 YMC 18.54.030(A)
  • 1.5 + (1 ÷ 10) spaces per unit9 YMC 18.54.030(A)
  • 2 + (1 ÷ 10) spaces per unit10 YMC 18.54.030(A)
  • 1 space per unit11 YMC 18.54.030(A)
  • 1.5 spaces per unit12 YMC 18.54.030(A)
for Multifamily dwellings (4+ units)
(beds in the project ÷ 2) + employees on the largest shift spaces YMC 18.54.030(B)
for Residential care facilities (group living); Convalescent care facilities (group living); Assisted living facilities (group living); Congregate care facilities (group living)
For special uses, the parking requirement shall be as provided in that chapter or as determined by the site plan review committee. YMC 18.54.030
for Emergency housing (group living); Emergency shelters (group living); Permanent supportive housing (group living); Transitional housing (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision YMC 18.13.030(A)-(B) A up to 9 YMC 18.13.030(A) —
Minimum lot size
No limit YMC 18.33.040(B)
Maximum lot size
Not set YMC 18.33.040
Minimum lot width
Not set YMC 18.33.040
Minimum lot depth
Not set YMC 18.33.040
Minimum frontage
Not set YMC 18.33.040
Maximum units per lot
Not set YMC 18.33.040
Administrative subdivision YMC 18.13.040(A)-(B) A 10 to 24 YMC 18.13.040(A) —
Minimum lot size
No limit YMC 18.33.040(B)
Maximum lot size
Not set YMC 18.33.040
Minimum lot width
Not set YMC 18.33.040
Minimum lot depth
Not set YMC 18.33.040
Minimum frontage
Not set YMC 18.33.040
Maximum units per lot
Not set YMC 18.33.040
Preliminary subdivision YMC 18.14.050(A)-(B) H 25 or more YMC 18.14.050(A) —
Minimum lot size
No limit YMC 18.33.040(B)
Maximum lot size
Not set YMC 18.33.040
Minimum lot width
Not set YMC 18.33.040
Minimum lot depth
Not set YMC 18.33.040
Minimum frontage
Not set YMC 18.33.040
Maximum units per lot
Not set YMC 18.33.040

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The development occurs on an existing lot of record
    • Lot area is at most 43,560 sf
  2. None of these is true:
    • The project is a townhouse development or planned residential development that the city approves for the density bonus
  3. The project is a townhouse development or planned residential development that the city approves for the density bonus
  4. Class of the street the front yard faces: local access, collector or arterial street is local_access
  5. Class of the street the front yard faces: local access, collector or arterial street is collector
  6. Class of the street the front yard faces: local access, collector or arterial street is arterial
  7. Main dwelling units on the lot is at most 4
  8. All of these are true:
    • Main dwelling units on the lot is more than 4
    • Bedrooms in one unit is 0
    None of these is true:
    • The multifamily building is constructed along a major transit route
  9. All of these are true:
    • Main dwelling units on the lot is more than 4
    • Bedrooms in one unit is at least 1
    • Bedrooms in one unit is at most 2
    None of these is true:
    • The multifamily building is constructed along a major transit route
  10. All of these are true:
    • Main dwelling units on the lot is more than 4
    • Bedrooms in one unit is at least 3
    None of these is true:
    • The multifamily building is constructed along a major transit route
  11. All of these are true:
    • Main dwelling units on the lot is more than 4
    • The multifamily building is constructed along a major transit route
    • Bedrooms in one unit is at most 1
  12. All of these are true:
    • Main dwelling units on the lot is more than 4
    • The multifamily building is constructed along a major transit route
    • Bedrooms in one unit is at least 2